Increased Bite Distance From the Edge Lowers Risk of Pullout of Simple Sutures from Acellular Dermal Allograft
To investigate whether pullout strength in the acellular dermal allograft matrix (ADM) used for superior capsule reconstruction depends on the distance from the edge of the graft. ADM used for superior capsule reconstruction was obtained and cut into 30 squares. Two sutures were placed through the c...
Saved in:
Published in: | Arthroscopy, Sports Medicine, and Rehabilitation Sports Medicine, and Rehabilitation, 2021-10, Vol.3 (5), p.e1513-e1516 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | To investigate whether pullout strength in the acellular dermal allograft matrix (ADM) used for superior capsule reconstruction depends on the distance from the edge of the graft.
ADM used for superior capsule reconstruction was obtained and cut into 30 squares. Two sutures were placed through the center of each graft by using a loaded Keith needle and forming a simple stitch. The grafts were divided into 3 groups of 10 grafts with a distance of 5 mm, 10 mm or 15 mm from the closest edge of the graft, respectively. The grafts were then preloaded to 5 N and pulled to failure at a rate of 12 mm/s on an MTS 858 MiniBionix servohydraulic mechanical test frame. The load to failure was recorded as well as the stiffness of each graft.
The mean load to failure was 34.5 N (SD 7.89) for the 5 mm grafts, 31.7 N (SD 5.99) for the 10 mm grafts, and 66.2 N (SD 18.4) for the 15 mm grafts. There was a significant difference ( |
---|---|
ISSN: | 2666-061X 2666-061X |