Bronchial Foreign Body Aspiration Due to Polycarbophil Calcium
Polycarbophil calcium (Polyful®; Mylan, Tokyo, Japan) is a stool stabilizer that absorbs liquid and swells to form a soft, bulky mass. A 75-year-old woman experienced sore throat and difficulty breathing immediately after taking the drug. Chest computed tomography showed a foreign body in the right...
Saved in:
Published in: | Internal Medicine 2021/10/15, Vol.60(20), pp.3295-3297 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Polycarbophil calcium (Polyful®; Mylan, Tokyo, Japan) is a stool stabilizer that absorbs liquid and swells to form a soft, bulky mass. A 75-year-old woman experienced sore throat and difficulty breathing immediately after taking the drug. Chest computed tomography showed a foreign body in the right intermediate bronchus. Bronchoscopy showed a white mass blocking the right intermediate bronchus. Since the mass was very fragile, we performed suctioning while breaking up the mass with a suction tube. The mass consisted of polycarbophil calcium. Since aspirated polycarbophil calcium swells and can obstruct bronchi, complete removal is crucial. |
---|---|
ISSN: | 0918-2918 1349-7235 |
DOI: | 10.2169/internalmedicine.7030-21 |