Loading…

Effect Steel Fibre Content on the Load-Carrying Capacity of Fibre-Reinforced Concrete Expansion Anchor

The article presents the pull-out strength tests carried out on M10 expansion anchors in non-cracked and cracked concrete with a crack width c = 0.30 mm. The breaking loads and the average pull-out strength of anchors in fibre-reinforced concrete substrates were determined. Fibre content ratios of 1...

Full description

Saved in:
Bibliographic Details
Published in:Materials 2021-12, Vol.14 (24), p.7757
Main Authors: Dudek, Daniel, Kadela, Marta, Małek, Marcin
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The article presents the pull-out strength tests carried out on M10 expansion anchors in non-cracked and cracked concrete with a crack width c = 0.30 mm. The breaking loads and the average pull-out strength of anchors in fibre-reinforced concrete substrates were determined. Fibre content ratios of 15, 30 and 50 kg/m were used. In addition, two different classes of concrete (C20/25 and C50/60) were tested. The addition of steel fibres caused a decrease in the pull-out strength by 5% for non-cracked concrete of C20/25 class and fibre content up to 30 kg/m and a further 7% for the remaining specified dosage. While for concrete of the C50/60 class, it a decrease in the pull-out strength of up to 20% was observed. For cracked concrete class C20/25 with crack initiation c = 0.30 mm, the reduction was from 9% to 16% in relation to non-cracked concrete and a maximum of 18% for the fibre content of 50 kg/m . The difference between the tensile load capacity of C50/60 class cracked and non-cracked concrete was lower than 5% and fell within the measurement error.
ISSN:1996-1944
1996-1944
DOI:10.3390/ma14247757