Determination of a Cut-off Point for Exhaled Nitric Oxide in the Diagnosis of Asthma in an Iranian Population

Asthma is a major source of global social and economic burden; thus, its early detection is important. Measurement of fractional exhaled nitric oxide (FENO) has been used recently considered a good indicator of asthma and also a sensitive and non-invasive method for monitoring airway inflammation. T...

Full description

Saved in:
Bibliographic Details
Published in:Tanaffus 2021-02, Vol.20 (2), p.150-155
Main Authors: Borhani Fard, Mohammad, Samet, Mohammad, Salmani Nodoushan, Mojahede, Mehrparvar, Amir Houshang, Bahrami-Ahmadi, Amir
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Asthma is a major source of global social and economic burden; thus, its early detection is important. Measurement of fractional exhaled nitric oxide (FENO) has been used recently considered a good indicator of asthma and also a sensitive and non-invasive method for monitoring airway inflammation. This study was conducted to determine the cut-off point of FENO for the diagnosis of asthma in the studied population. The subjects of this cross-sectional diagnostic study were assessed by the FENO test, spirometry, and methacholine challenge test. The best cut-off point of the FENO for the diagnosis of asthma was determined. The data were analyzed by SPSS 20 using student t-test, and Chi-square test and the ROC curves were also drawn. The mean FENO in asthmatic and non-asthmatic subjects was 43.5±33.41 and 17.5±21.48 ppb, respectively (P