Loading…
Long-term clinicoradiological outcomes of cervical fusion with polyether ether ketone versus cervical disc arthroplasty in a double-blinded randomized control trial
Introduction: In this double-blinded randomized controlled trial, we compare the long-term clinicoradiological effects of anterior cervical discectomy and fusion with polyether ether ketone implant (ACDF with PEEK) versus artificial cervical disc (cervical disc arthroplasty [CDA]) in patients with s...
Saved in:
Published in: | Asian journal of neurosurgery 2021-10, Vol.16 (4), p.725-731 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Introduction:
In this double-blinded randomized controlled trial, we compare the long-term clinicoradiological effects of anterior cervical discectomy and fusion with polyether ether ketone implant (ACDF with PEEK) versus artificial cervical disc (cervical disc arthroplasty [CDA]) in patients with single and bilevel cervical degenerative disc disease (CDDD).
Aims:
We aimed to compare the pain scores, cervical kinematics, and radiological outcomes in patients undergoing CDA and ACDF for single and bilevel CDDD over 5 years.
Settings and Design:
This study was carried out from 2010 to 2019 in the Neurosurgery Department of a Tertiary Care Hospital attached to a Medical College in India. Subjects and
Methods:
We enrolled 30 patients in each group. Clinical and radiological assessments were carried out for all patients over a period of 5 years. Statistical Analysis Used: Wilcoxon Signed-rank test, Mann–Whitney U-test, and Fischer's exact test were used for comparing the preoperative and follow-uP values. R software version 3.6.0 was used for statistical analysis.
Results:
A significant improvement in the cervical range of motion, sagittal range of motion (ROM), and functional spinal unit (FSU) was observed in the CDA group at final follow-up, while the PEEK group reported a significant decrease in the ROM and FSU and the difference between the two groups was also found to be statistically significant.
Conclusions:
When assessed over 5 years following surgery, we found CDA to be superior with respect to ROM, FSU, overall cervical alignment, and maintenance of disc height when compared to ACDF with PEEK implant. |
---|---|
ISSN: | 1793-5482 2248-9614 |
DOI: | 10.4103/ajns.AJNS_345_20 |