Loading…
Effect of Pterygium Removal Combined with Conjunctival Autograft on Corneal Parameters in Swept-Source Imaging
Both pterygium ingrowth and excision determine alterations in corneal topography. The aim of this study was to evaluate the influence of pterygium removal combined with conjunctival autografts in addition to the use of human fibrin tissue glue on changes in corneal parameters as measured by 3-D swep...
Saved in:
Published in: | Journal of clinical medicine 2022-01, Vol.11 (2), p.329 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c409t-6e25382cdbf4e1b7342b5a10b7825b3b12d37996a056ea30af9b8d5410b980b83 |
---|---|
cites | cdi_FETCH-LOGICAL-c409t-6e25382cdbf4e1b7342b5a10b7825b3b12d37996a056ea30af9b8d5410b980b83 |
container_end_page | |
container_issue | 2 |
container_start_page | 329 |
container_title | Journal of clinical medicine |
container_volume | 11 |
creator | Wiącek, Marta P Kuśmierz-Wojtasik, Monika Kowalska, Bogna Machalińska, Anna |
description | Both pterygium ingrowth and excision determine alterations in corneal topography. The aim of this study was to evaluate the influence of pterygium removal combined with conjunctival autografts in addition to the use of human fibrin tissue glue on changes in corneal parameters as measured by 3-D swept-source anterior segment optical coherence tomography (AS-OCT) imaging.
Sixteen eyes (16 patients) with pterygium that qualified for surgical treatment were enrolled in this study. Eye examination, slit lamp, and 3-D AS-OCT (CASIA 2) assessment were performed before the surgery and 7 days, 1 month, and 6 months after pterygium excision. Topographic parameters of both anterior and posterior surfaces of the cornea were analysed at each follow-up visit.
The gradual decrease in total astigmatism power from preoperative median 2.75 (6.15) D to 1.2 (1.1) D at 6-month follow-up (
= 0.034) was noted from the day 7 visit. Values were strongly influenced by variations of anterior cornea astigmatism. In contrast, a gradual total HOA reduction at the 1-month (from median 0.79 (1.3) D to 0.44 (0.27) D;
= 0.038) and at 6-month visits (0.25 (0.09);
= 0.001) was observed. Similarly, values were strongly influenced by variations of the anterior. Additionally, total average keratometry values increased from preoperative 44.05 (2.25) D to 44.6 (1.9) (
= 0.043) 1 month after the surgery.
Significant steepening of the anterior cornea and a reduction in both astigmatism and HOA were observed after pterygium excision. The anterior corneal surface was an essential component of the total postoperative corneal topography values. Three-dimensional swept-source AS-OCT imaging seems to be a valuable tool for monitoring both the progression of the disease and postoperative effects in pterygium eyes. |
doi_str_mv | 10.3390/jcm11020329 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8778267</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2622276389</sourcerecordid><originalsourceid>FETCH-LOGICAL-c409t-6e25382cdbf4e1b7342b5a10b7825b3b12d37996a056ea30af9b8d5410b980b83</originalsourceid><addsrcrecordid>eNpdkc1LHTEUxUOxVFFX3ZcBNwWZmo-ZSWZTkIdVQajUdh2SzJ0xj0nyTDKK_33z0Mqr2eTj_HJybw5Cnwn-xliPz9bGEYIpZrT_gA4o5rzGTLC9nfU-Ok5pjcsQoqGEf0L7rMVtgyk7QP5iHMHkKozVbYb4PNnFVb_AhUc1V6vgtPUwVE8235edXy_eZLuVzpccpqjGctMXJXooh7cqKgfFJlXWV3dPsMn1XViigeraqcn66Qh9HNWc4Ph1PkR_flz8Xl3VNz8vr1fnN7VpcJ_rDmjLBDWDHhsgmrOG6lYRrLmgrWaa0IHxvu8UbjtQDKux12Jom0L0AmvBDtH3F9_Noh0MBnyOapabaJ2KzzIoK_9XvL2XU3iUgpcnOl4Mvr4axPCwQMrS2WRgnpWHsCRJO0op75joC3ryDl2Xnn1pb0sRRstv00KdvlAmhpQijG_FECy3UcqdKAv9Zbf-N_ZfcOwvfNCaFw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2621323502</pqid></control><display><type>article</type><title>Effect of Pterygium Removal Combined with Conjunctival Autograft on Corneal Parameters in Swept-Source Imaging</title><source>PubMed (Medline)</source><source>Publicly Available Content Database</source><creator>Wiącek, Marta P ; Kuśmierz-Wojtasik, Monika ; Kowalska, Bogna ; Machalińska, Anna</creator><creatorcontrib>Wiącek, Marta P ; Kuśmierz-Wojtasik, Monika ; Kowalska, Bogna ; Machalińska, Anna</creatorcontrib><description>Both pterygium ingrowth and excision determine alterations in corneal topography. The aim of this study was to evaluate the influence of pterygium removal combined with conjunctival autografts in addition to the use of human fibrin tissue glue on changes in corneal parameters as measured by 3-D swept-source anterior segment optical coherence tomography (AS-OCT) imaging.
Sixteen eyes (16 patients) with pterygium that qualified for surgical treatment were enrolled in this study. Eye examination, slit lamp, and 3-D AS-OCT (CASIA 2) assessment were performed before the surgery and 7 days, 1 month, and 6 months after pterygium excision. Topographic parameters of both anterior and posterior surfaces of the cornea were analysed at each follow-up visit.
The gradual decrease in total astigmatism power from preoperative median 2.75 (6.15) D to 1.2 (1.1) D at 6-month follow-up (
= 0.034) was noted from the day 7 visit. Values were strongly influenced by variations of anterior cornea astigmatism. In contrast, a gradual total HOA reduction at the 1-month (from median 0.79 (1.3) D to 0.44 (0.27) D;
= 0.038) and at 6-month visits (0.25 (0.09);
= 0.001) was observed. Similarly, values were strongly influenced by variations of the anterior. Additionally, total average keratometry values increased from preoperative 44.05 (2.25) D to 44.6 (1.9) (
= 0.043) 1 month after the surgery.
Significant steepening of the anterior cornea and a reduction in both astigmatism and HOA were observed after pterygium excision. The anterior corneal surface was an essential component of the total postoperative corneal topography values. Three-dimensional swept-source AS-OCT imaging seems to be a valuable tool for monitoring both the progression of the disease and postoperative effects in pterygium eyes.</description><identifier>ISSN: 2077-0383</identifier><identifier>EISSN: 2077-0383</identifier><identifier>DOI: 10.3390/jcm11020329</identifier><identifier>PMID: 35054023</identifier><language>eng</language><publisher>Switzerland: MDPI AG</publisher><subject>Clinical medicine ; Cornea ; Disease ; Eye examinations ; Fourier analysis ; Patients ; Statistical analysis ; Surgery ; Topography ; Variance analysis</subject><ispartof>Journal of clinical medicine, 2022-01, Vol.11 (2), p.329</ispartof><rights>2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>2022 by the authors. 2022</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c409t-6e25382cdbf4e1b7342b5a10b7825b3b12d37996a056ea30af9b8d5410b980b83</citedby><cites>FETCH-LOGICAL-c409t-6e25382cdbf4e1b7342b5a10b7825b3b12d37996a056ea30af9b8d5410b980b83</cites><orcidid>0000-0002-1013-135X ; 0000-0001-9806-9724 ; 0000-0003-1190-717X ; 0000-0001-9416-5030</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2621323502/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2621323502?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,25753,27924,27925,37012,37013,44590,53791,53793,75126</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/35054023$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Wiącek, Marta P</creatorcontrib><creatorcontrib>Kuśmierz-Wojtasik, Monika</creatorcontrib><creatorcontrib>Kowalska, Bogna</creatorcontrib><creatorcontrib>Machalińska, Anna</creatorcontrib><title>Effect of Pterygium Removal Combined with Conjunctival Autograft on Corneal Parameters in Swept-Source Imaging</title><title>Journal of clinical medicine</title><addtitle>J Clin Med</addtitle><description>Both pterygium ingrowth and excision determine alterations in corneal topography. The aim of this study was to evaluate the influence of pterygium removal combined with conjunctival autografts in addition to the use of human fibrin tissue glue on changes in corneal parameters as measured by 3-D swept-source anterior segment optical coherence tomography (AS-OCT) imaging.
Sixteen eyes (16 patients) with pterygium that qualified for surgical treatment were enrolled in this study. Eye examination, slit lamp, and 3-D AS-OCT (CASIA 2) assessment were performed before the surgery and 7 days, 1 month, and 6 months after pterygium excision. Topographic parameters of both anterior and posterior surfaces of the cornea were analysed at each follow-up visit.
The gradual decrease in total astigmatism power from preoperative median 2.75 (6.15) D to 1.2 (1.1) D at 6-month follow-up (
= 0.034) was noted from the day 7 visit. Values were strongly influenced by variations of anterior cornea astigmatism. In contrast, a gradual total HOA reduction at the 1-month (from median 0.79 (1.3) D to 0.44 (0.27) D;
= 0.038) and at 6-month visits (0.25 (0.09);
= 0.001) was observed. Similarly, values were strongly influenced by variations of the anterior. Additionally, total average keratometry values increased from preoperative 44.05 (2.25) D to 44.6 (1.9) (
= 0.043) 1 month after the surgery.
Significant steepening of the anterior cornea and a reduction in both astigmatism and HOA were observed after pterygium excision. The anterior corneal surface was an essential component of the total postoperative corneal topography values. Three-dimensional swept-source AS-OCT imaging seems to be a valuable tool for monitoring both the progression of the disease and postoperative effects in pterygium eyes.</description><subject>Clinical medicine</subject><subject>Cornea</subject><subject>Disease</subject><subject>Eye examinations</subject><subject>Fourier analysis</subject><subject>Patients</subject><subject>Statistical analysis</subject><subject>Surgery</subject><subject>Topography</subject><subject>Variance analysis</subject><issn>2077-0383</issn><issn>2077-0383</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNpdkc1LHTEUxUOxVFFX3ZcBNwWZmo-ZSWZTkIdVQajUdh2SzJ0xj0nyTDKK_33z0Mqr2eTj_HJybw5Cnwn-xliPz9bGEYIpZrT_gA4o5rzGTLC9nfU-Ok5pjcsQoqGEf0L7rMVtgyk7QP5iHMHkKozVbYb4PNnFVb_AhUc1V6vgtPUwVE8235edXy_eZLuVzpccpqjGctMXJXooh7cqKgfFJlXWV3dPsMn1XViigeraqcn66Qh9HNWc4Ph1PkR_flz8Xl3VNz8vr1fnN7VpcJ_rDmjLBDWDHhsgmrOG6lYRrLmgrWaa0IHxvu8UbjtQDKux12Jom0L0AmvBDtH3F9_Noh0MBnyOapabaJ2KzzIoK_9XvL2XU3iUgpcnOl4Mvr4axPCwQMrS2WRgnpWHsCRJO0op75joC3ryDl2Xnn1pb0sRRstv00KdvlAmhpQijG_FECy3UcqdKAv9Zbf-N_ZfcOwvfNCaFw</recordid><startdate>20220110</startdate><enddate>20220110</enddate><creator>Wiącek, Marta P</creator><creator>Kuśmierz-Wojtasik, Monika</creator><creator>Kowalska, Bogna</creator><creator>Machalińska, Anna</creator><general>MDPI AG</general><general>MDPI</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-1013-135X</orcidid><orcidid>https://orcid.org/0000-0001-9806-9724</orcidid><orcidid>https://orcid.org/0000-0003-1190-717X</orcidid><orcidid>https://orcid.org/0000-0001-9416-5030</orcidid></search><sort><creationdate>20220110</creationdate><title>Effect of Pterygium Removal Combined with Conjunctival Autograft on Corneal Parameters in Swept-Source Imaging</title><author>Wiącek, Marta P ; Kuśmierz-Wojtasik, Monika ; Kowalska, Bogna ; Machalińska, Anna</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c409t-6e25382cdbf4e1b7342b5a10b7825b3b12d37996a056ea30af9b8d5410b980b83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Clinical medicine</topic><topic>Cornea</topic><topic>Disease</topic><topic>Eye examinations</topic><topic>Fourier analysis</topic><topic>Patients</topic><topic>Statistical analysis</topic><topic>Surgery</topic><topic>Topography</topic><topic>Variance analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wiącek, Marta P</creatorcontrib><creatorcontrib>Kuśmierz-Wojtasik, Monika</creatorcontrib><creatorcontrib>Kowalska, Bogna</creatorcontrib><creatorcontrib>Machalińska, Anna</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Collection (ProQuest Medical & Health Databases)</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of clinical medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wiącek, Marta P</au><au>Kuśmierz-Wojtasik, Monika</au><au>Kowalska, Bogna</au><au>Machalińska, Anna</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of Pterygium Removal Combined with Conjunctival Autograft on Corneal Parameters in Swept-Source Imaging</atitle><jtitle>Journal of clinical medicine</jtitle><addtitle>J Clin Med</addtitle><date>2022-01-10</date><risdate>2022</risdate><volume>11</volume><issue>2</issue><spage>329</spage><pages>329-</pages><issn>2077-0383</issn><eissn>2077-0383</eissn><abstract>Both pterygium ingrowth and excision determine alterations in corneal topography. The aim of this study was to evaluate the influence of pterygium removal combined with conjunctival autografts in addition to the use of human fibrin tissue glue on changes in corneal parameters as measured by 3-D swept-source anterior segment optical coherence tomography (AS-OCT) imaging.
Sixteen eyes (16 patients) with pterygium that qualified for surgical treatment were enrolled in this study. Eye examination, slit lamp, and 3-D AS-OCT (CASIA 2) assessment were performed before the surgery and 7 days, 1 month, and 6 months after pterygium excision. Topographic parameters of both anterior and posterior surfaces of the cornea were analysed at each follow-up visit.
The gradual decrease in total astigmatism power from preoperative median 2.75 (6.15) D to 1.2 (1.1) D at 6-month follow-up (
= 0.034) was noted from the day 7 visit. Values were strongly influenced by variations of anterior cornea astigmatism. In contrast, a gradual total HOA reduction at the 1-month (from median 0.79 (1.3) D to 0.44 (0.27) D;
= 0.038) and at 6-month visits (0.25 (0.09);
= 0.001) was observed. Similarly, values were strongly influenced by variations of the anterior. Additionally, total average keratometry values increased from preoperative 44.05 (2.25) D to 44.6 (1.9) (
= 0.043) 1 month after the surgery.
Significant steepening of the anterior cornea and a reduction in both astigmatism and HOA were observed after pterygium excision. The anterior corneal surface was an essential component of the total postoperative corneal topography values. Three-dimensional swept-source AS-OCT imaging seems to be a valuable tool for monitoring both the progression of the disease and postoperative effects in pterygium eyes.</abstract><cop>Switzerland</cop><pub>MDPI AG</pub><pmid>35054023</pmid><doi>10.3390/jcm11020329</doi><orcidid>https://orcid.org/0000-0002-1013-135X</orcidid><orcidid>https://orcid.org/0000-0001-9806-9724</orcidid><orcidid>https://orcid.org/0000-0003-1190-717X</orcidid><orcidid>https://orcid.org/0000-0001-9416-5030</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2077-0383 |
ispartof | Journal of clinical medicine, 2022-01, Vol.11 (2), p.329 |
issn | 2077-0383 2077-0383 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8778267 |
source | PubMed (Medline); Publicly Available Content Database |
subjects | Clinical medicine Cornea Disease Eye examinations Fourier analysis Patients Statistical analysis Surgery Topography Variance analysis |
title | Effect of Pterygium Removal Combined with Conjunctival Autograft on Corneal Parameters in Swept-Source Imaging |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T12%3A33%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20Pterygium%20Removal%20Combined%20with%20Conjunctival%20Autograft%20on%20Corneal%20Parameters%20in%20Swept-Source%20Imaging&rft.jtitle=Journal%20of%20clinical%20medicine&rft.au=Wi%C4%85cek,%20Marta%20P&rft.date=2022-01-10&rft.volume=11&rft.issue=2&rft.spage=329&rft.pages=329-&rft.issn=2077-0383&rft.eissn=2077-0383&rft_id=info:doi/10.3390/jcm11020329&rft_dat=%3Cproquest_pubme%3E2622276389%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c409t-6e25382cdbf4e1b7342b5a10b7825b3b12d37996a056ea30af9b8d5410b980b83%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2621323502&rft_id=info:pmid/35054023&rfr_iscdi=true |