Implementation of an Online Glaucoma-Specific Quality of Life Computerized Adaptive Test System in a US Glaucoma Hospital
The feasibility of implementing a computerized adaptive test (CAT) system in routine clinical care in ophthalmology has not been assessed. We evaluated the implementation of a glaucoma-specific CAT (GlauCAT) in outpatients at Massachusetts Eye and Ear Institute. In this implementation study (July 20...
Saved in:
Published in: | Translational vision science & technology 2022-02, Vol.11 (2), p.24-24 |
---|---|
Main Authors: | , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The feasibility of implementing a computerized adaptive test (CAT) system in routine clinical care in ophthalmology has not been assessed. We evaluated the implementation of a glaucoma-specific CAT (GlauCAT) in outpatients at Massachusetts Eye and Ear Institute.
In this implementation study (July 2020-April 2021), 216 adults (mean ± SD age 64.8 ± 15.3 years; 56.0% women) completed six adaptive GlauCAT quality of life (QOL) tests on an internet-enabled tablet at the clinic. A real-time printable report summarizing domain scores was shared with physicians prior to consultation. The implementation was evaluated using Proctor's outcomes: acceptability (patient satisfaction); appropriateness (independent complete rate [%]); feasibility (acceptance rate [%]; completion time); and fidelity (percentage of patients discussing GlauCAT results with their physician). Physician barriers/facilitators were explored using open-ended questions.
Patients' mean ± SD satisfaction score was 3.5 ± 0.5 of 4, with >95% of patients willing to recommend it to others. Of the 216 (89.2%) patients accepting to participate, 173 (80%) completed GlauCAT independently. Patients took 8 minutes and 5 seconds (median) to complete all 6 GlauCAT tests. Almost two-thirds (n = 136/216) of the patients reported discussing their GlauCAT results with their doctor. Physicians described the GlauCAT summary report as helpful and user-friendly, although lack of time and uncertainty about how to action information were reported.
Pilot implementation of six GlauCAT QOL tests in glaucoma outpatient clinics was feasible and acceptable. Integration of GlauCAT with electronic medical records (EMRs) and evaluation of long-term implementation outcomes are needed.
GlauCAT's multiple outcomes and low test-taking burden makes it attractive for measuring glaucoma-specific QOL in routine clinical care. |
---|---|