Loading…

Measurement Comparability of Electronic and Paper Administration of Visual Analogue Scales: A Review of Published Studies

Background Visual analogue scales (VASs) are used in a variety of patient-, observer- and clinician-reported outcome measures. While typically included in measures originally developed for pen-and-paper completion, a greater number of clinical trials currently use electronic approaches to their coll...

Full description

Saved in:
Bibliographic Details
Published in:Therapeutic innovation & regulatory science 2022-05, Vol.56 (3), p.394-404
Main Authors: Byrom, Bill, Elash, Celeste A., Eremenco, Sonya, Bodart, Serge, Muehlhausen, Willie, Platko, Jill V., Watson, Chris, Howry, Cindy
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background Visual analogue scales (VASs) are used in a variety of patient-, observer- and clinician-reported outcome measures. While typically included in measures originally developed for pen-and-paper completion, a greater number of clinical trials currently use electronic approaches to their collection. This leads researchers to question whether the measurement properties of the scale have been conserved during the migration to an electronic format, particularly because electronic formats often use a different scale length than the 100 mm paper standard. Methods We performed a review of published studies investigating the measurement comparability of paper and electronic formats of the VAS. Results Our literature search yielded 26 studies published between 1997 and 2018 that reported comparison of paper and electronic formats using the VAS. After excluding 2 publications, 23 of the remaining 24 studies included in this review reported electronic formats of the VAS (eVAS) and paper formats (pVAS) to be equivalent. A further study concluded that eVAS and pVAS were both acceptable but should not be interchanged. eVAS length varied from 21 to 200 mm, indicating that 100 mm length is not a requirement. Conclusions The literature supports the hypothesis that eVAS and pVAS provide comparable results regardless of the VAS length. When implementing a VAS on a screen-based electronic mode, we recommend following industry best practices for faithful migration to minimise the likelihood of non-comparability with pVAS.
ISSN:2168-4790
2168-4804
DOI:10.1007/s43441-022-00376-2