Loading…

Plating Distal Radius Fractures Using Wide-Awake Local Anesthesia No Tourniquet (WALANT) Versus General Anesthesia: A Cohort Study

This study compared outcomes of plating distal radius (DR) fractures using wide-awake local anesthesia no tourniquet (WALANT) versus general anesthesia (GA). From March 2018 to March 2019, 20 patients with DR fracture underwent plating using WALANT whereas 20 patients who underwent plating under GA...

Full description

Saved in:
Bibliographic Details
Published in:Journal of hand surgery global online 2020-11, Vol.2 (6), p.331-338
Main Authors: Yi, Liew Mei, Ahmad, Amir Adham, Ruslan, Shairil Rahayu, Abdullah, Shalimar, Ahmad, Abdul Rauf
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c3703-4c5f8eb55c90626306f3c61da43ddacf6c72fefcc8f504e642d80ca5c5b320ab3
cites cdi_FETCH-LOGICAL-c3703-4c5f8eb55c90626306f3c61da43ddacf6c72fefcc8f504e642d80ca5c5b320ab3
container_end_page 338
container_issue 6
container_start_page 331
container_title Journal of hand surgery global online
container_volume 2
creator Yi, Liew Mei
Ahmad, Amir Adham
Ruslan, Shairil Rahayu
Abdullah, Shalimar
Ahmad, Abdul Rauf
description This study compared outcomes of plating distal radius (DR) fractures using wide-awake local anesthesia no tourniquet (WALANT) versus general anesthesia (GA). From March 2018 to March 2019, 20 patients with DR fracture underwent plating using WALANT whereas 20 patients who underwent plating under GA were used as controls. Outcomes evaluated were pain control, waiting time for the operation, hemodynamic changes, blood loss, the occurrence of adverse effects of medications used in WALANT and GA, and the duration of postoperative stay. The WALANT group experienced a significantly shorter waiting time for surgery (6 vs 20 days; P < .001) and a shorter postoperative stay (1 vs 2 days; P = .009) compared with the GA group. They also reported mild to no pain during surgery. The groups were similar with regard to blood pressure, blood loss, and operative time. None in the WALANT group required conversion to GA during surgery and no adverse effects were reported. The WALANT approach is a viable alternative to GA for plating of DR fractures. Therapeutic III.
doi_str_mv 10.1016/j.jhsg.2020.09.003
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8991627</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S2589514120301079</els_id><sourcerecordid>2649995353</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3703-4c5f8eb55c90626306f3c61da43ddacf6c72fefcc8f504e642d80ca5c5b320ab3</originalsourceid><addsrcrecordid>eNp9kU9v1DAQxS0EolXpF-CAfCyHpP4TJzFCSNFCC9KqINjSo-W1J7tesnGxnaJe-8nxakvVXjh5pHnv55l5CL2mpKSE1qebcrOOq5IRRkoiS0L4M3TIRCsLQSv6_FF9gI5j3BBCWCO5YO1LdMBFRYVgzSG6-zbo5MYV_uhi0gP-rq2bIj4L2qQpQMSXcde9chaK7o_-BXjuTdZ1I8S0hug0vvB44acwut8TJHxy1c27i8Vb_BNCzKRzGCE8MbzDHZ75tQ8J_0iTvX2FXvR6iHB8_x6hy7NPi9nnYv71_MusmxeGN4QXlRF9C0shjCQ1qzmpe25qanXFrdWmr03DeuiNaXtBKqgrZltitDBiyRnRS36EPuy519NyC9bAmPJg6jq4rQ63ymunnnZGt1Yrf6NaKWnNmgw4uQcEn3eNSW1dNDAMegQ_RcXqSkopuOBZyvZSE3yMAfqHbyhRu_zURu3yU7v8FJEq55dNbx4P-GD5l1YWvN8LIJ_pxkFQ0TgYDVgXwCRlvfsf_y_p5q3O</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2649995353</pqid></control><display><type>article</type><title>Plating Distal Radius Fractures Using Wide-Awake Local Anesthesia No Tourniquet (WALANT) Versus General Anesthesia: A Cohort Study</title><source>NCBI_PubMed Central(免费)</source><source>ScienceDirect (Online service)</source><creator>Yi, Liew Mei ; Ahmad, Amir Adham ; Ruslan, Shairil Rahayu ; Abdullah, Shalimar ; Ahmad, Abdul Rauf</creator><creatorcontrib>Yi, Liew Mei ; Ahmad, Amir Adham ; Ruslan, Shairil Rahayu ; Abdullah, Shalimar ; Ahmad, Abdul Rauf</creatorcontrib><description>This study compared outcomes of plating distal radius (DR) fractures using wide-awake local anesthesia no tourniquet (WALANT) versus general anesthesia (GA). From March 2018 to March 2019, 20 patients with DR fracture underwent plating using WALANT whereas 20 patients who underwent plating under GA were used as controls. Outcomes evaluated were pain control, waiting time for the operation, hemodynamic changes, blood loss, the occurrence of adverse effects of medications used in WALANT and GA, and the duration of postoperative stay. The WALANT group experienced a significantly shorter waiting time for surgery (6 vs 20 days; P &lt; .001) and a shorter postoperative stay (1 vs 2 days; P = .009) compared with the GA group. They also reported mild to no pain during surgery. The groups were similar with regard to blood pressure, blood loss, and operative time. None in the WALANT group required conversion to GA during surgery and no adverse effects were reported. The WALANT approach is a viable alternative to GA for plating of DR fractures. Therapeutic III.</description><identifier>ISSN: 2589-5141</identifier><identifier>EISSN: 2589-5141</identifier><identifier>DOI: 10.1016/j.jhsg.2020.09.003</identifier><identifier>PMID: 35415527</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Bleeding ; Lidocaine ; Original Research ; Pain ; Radius</subject><ispartof>Journal of hand surgery global online, 2020-11, Vol.2 (6), p.331-338</ispartof><rights>2020 The Authors</rights><rights>2020 The Authors.</rights><rights>2020 The Authors 2020</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3703-4c5f8eb55c90626306f3c61da43ddacf6c72fefcc8f504e642d80ca5c5b320ab3</citedby><cites>FETCH-LOGICAL-c3703-4c5f8eb55c90626306f3c61da43ddacf6c72fefcc8f504e642d80ca5c5b320ab3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8991627/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S2589514120301079$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,3547,27923,27924,45779,53790,53792</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/35415527$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Yi, Liew Mei</creatorcontrib><creatorcontrib>Ahmad, Amir Adham</creatorcontrib><creatorcontrib>Ruslan, Shairil Rahayu</creatorcontrib><creatorcontrib>Abdullah, Shalimar</creatorcontrib><creatorcontrib>Ahmad, Abdul Rauf</creatorcontrib><title>Plating Distal Radius Fractures Using Wide-Awake Local Anesthesia No Tourniquet (WALANT) Versus General Anesthesia: A Cohort Study</title><title>Journal of hand surgery global online</title><addtitle>J Hand Surg Glob Online</addtitle><description>This study compared outcomes of plating distal radius (DR) fractures using wide-awake local anesthesia no tourniquet (WALANT) versus general anesthesia (GA). From March 2018 to March 2019, 20 patients with DR fracture underwent plating using WALANT whereas 20 patients who underwent plating under GA were used as controls. Outcomes evaluated were pain control, waiting time for the operation, hemodynamic changes, blood loss, the occurrence of adverse effects of medications used in WALANT and GA, and the duration of postoperative stay. The WALANT group experienced a significantly shorter waiting time for surgery (6 vs 20 days; P &lt; .001) and a shorter postoperative stay (1 vs 2 days; P = .009) compared with the GA group. They also reported mild to no pain during surgery. The groups were similar with regard to blood pressure, blood loss, and operative time. None in the WALANT group required conversion to GA during surgery and no adverse effects were reported. The WALANT approach is a viable alternative to GA for plating of DR fractures. Therapeutic III.</description><subject>Bleeding</subject><subject>Lidocaine</subject><subject>Original Research</subject><subject>Pain</subject><subject>Radius</subject><issn>2589-5141</issn><issn>2589-5141</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kU9v1DAQxS0EolXpF-CAfCyHpP4TJzFCSNFCC9KqINjSo-W1J7tesnGxnaJe-8nxakvVXjh5pHnv55l5CL2mpKSE1qebcrOOq5IRRkoiS0L4M3TIRCsLQSv6_FF9gI5j3BBCWCO5YO1LdMBFRYVgzSG6-zbo5MYV_uhi0gP-rq2bIj4L2qQpQMSXcde9chaK7o_-BXjuTdZ1I8S0hug0vvB44acwut8TJHxy1c27i8Vb_BNCzKRzGCE8MbzDHZ75tQ8J_0iTvX2FXvR6iHB8_x6hy7NPi9nnYv71_MusmxeGN4QXlRF9C0shjCQ1qzmpe25qanXFrdWmr03DeuiNaXtBKqgrZltitDBiyRnRS36EPuy519NyC9bAmPJg6jq4rQ63ymunnnZGt1Yrf6NaKWnNmgw4uQcEn3eNSW1dNDAMegQ_RcXqSkopuOBZyvZSE3yMAfqHbyhRu_zURu3yU7v8FJEq55dNbx4P-GD5l1YWvN8LIJ_pxkFQ0TgYDVgXwCRlvfsf_y_p5q3O</recordid><startdate>20201101</startdate><enddate>20201101</enddate><creator>Yi, Liew Mei</creator><creator>Ahmad, Amir Adham</creator><creator>Ruslan, Shairil Rahayu</creator><creator>Abdullah, Shalimar</creator><creator>Ahmad, Abdul Rauf</creator><general>Elsevier Inc</general><general>Elsevier</general><scope>6I.</scope><scope>AAFTH</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20201101</creationdate><title>Plating Distal Radius Fractures Using Wide-Awake Local Anesthesia No Tourniquet (WALANT) Versus General Anesthesia: A Cohort Study</title><author>Yi, Liew Mei ; Ahmad, Amir Adham ; Ruslan, Shairil Rahayu ; Abdullah, Shalimar ; Ahmad, Abdul Rauf</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3703-4c5f8eb55c90626306f3c61da43ddacf6c72fefcc8f504e642d80ca5c5b320ab3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Bleeding</topic><topic>Lidocaine</topic><topic>Original Research</topic><topic>Pain</topic><topic>Radius</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yi, Liew Mei</creatorcontrib><creatorcontrib>Ahmad, Amir Adham</creatorcontrib><creatorcontrib>Ruslan, Shairil Rahayu</creatorcontrib><creatorcontrib>Abdullah, Shalimar</creatorcontrib><creatorcontrib>Ahmad, Abdul Rauf</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of hand surgery global online</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yi, Liew Mei</au><au>Ahmad, Amir Adham</au><au>Ruslan, Shairil Rahayu</au><au>Abdullah, Shalimar</au><au>Ahmad, Abdul Rauf</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Plating Distal Radius Fractures Using Wide-Awake Local Anesthesia No Tourniquet (WALANT) Versus General Anesthesia: A Cohort Study</atitle><jtitle>Journal of hand surgery global online</jtitle><addtitle>J Hand Surg Glob Online</addtitle><date>2020-11-01</date><risdate>2020</risdate><volume>2</volume><issue>6</issue><spage>331</spage><epage>338</epage><pages>331-338</pages><issn>2589-5141</issn><eissn>2589-5141</eissn><abstract>This study compared outcomes of plating distal radius (DR) fractures using wide-awake local anesthesia no tourniquet (WALANT) versus general anesthesia (GA). From March 2018 to March 2019, 20 patients with DR fracture underwent plating using WALANT whereas 20 patients who underwent plating under GA were used as controls. Outcomes evaluated were pain control, waiting time for the operation, hemodynamic changes, blood loss, the occurrence of adverse effects of medications used in WALANT and GA, and the duration of postoperative stay. The WALANT group experienced a significantly shorter waiting time for surgery (6 vs 20 days; P &lt; .001) and a shorter postoperative stay (1 vs 2 days; P = .009) compared with the GA group. They also reported mild to no pain during surgery. The groups were similar with regard to blood pressure, blood loss, and operative time. None in the WALANT group required conversion to GA during surgery and no adverse effects were reported. The WALANT approach is a viable alternative to GA for plating of DR fractures. Therapeutic III.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>35415527</pmid><doi>10.1016/j.jhsg.2020.09.003</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2589-5141
ispartof Journal of hand surgery global online, 2020-11, Vol.2 (6), p.331-338
issn 2589-5141
2589-5141
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8991627
source NCBI_PubMed Central(免费); ScienceDirect (Online service)
subjects Bleeding
Lidocaine
Original Research
Pain
Radius
title Plating Distal Radius Fractures Using Wide-Awake Local Anesthesia No Tourniquet (WALANT) Versus General Anesthesia: A Cohort Study
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T03%3A00%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Plating%20Distal%20Radius%20Fractures%20Using%20Wide-Awake%20Local%20Anesthesia%20No%20Tourniquet%20(WALANT)%20Versus%20General%20Anesthesia:%20A%20Cohort%20Study&rft.jtitle=Journal%20of%20hand%20surgery%20global%20online&rft.au=Yi,%20Liew%20Mei&rft.date=2020-11-01&rft.volume=2&rft.issue=6&rft.spage=331&rft.epage=338&rft.pages=331-338&rft.issn=2589-5141&rft.eissn=2589-5141&rft_id=info:doi/10.1016/j.jhsg.2020.09.003&rft_dat=%3Cproquest_pubme%3E2649995353%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3703-4c5f8eb55c90626306f3c61da43ddacf6c72fefcc8f504e642d80ca5c5b320ab3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2649995353&rft_id=info:pmid/35415527&rfr_iscdi=true