Loading…
Plating Distal Radius Fractures Using Wide-Awake Local Anesthesia No Tourniquet (WALANT) Versus General Anesthesia: A Cohort Study
This study compared outcomes of plating distal radius (DR) fractures using wide-awake local anesthesia no tourniquet (WALANT) versus general anesthesia (GA). From March 2018 to March 2019, 20 patients with DR fracture underwent plating using WALANT whereas 20 patients who underwent plating under GA...
Saved in:
Published in: | Journal of hand surgery global online 2020-11, Vol.2 (6), p.331-338 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c3703-4c5f8eb55c90626306f3c61da43ddacf6c72fefcc8f504e642d80ca5c5b320ab3 |
---|---|
cites | cdi_FETCH-LOGICAL-c3703-4c5f8eb55c90626306f3c61da43ddacf6c72fefcc8f504e642d80ca5c5b320ab3 |
container_end_page | 338 |
container_issue | 6 |
container_start_page | 331 |
container_title | Journal of hand surgery global online |
container_volume | 2 |
creator | Yi, Liew Mei Ahmad, Amir Adham Ruslan, Shairil Rahayu Abdullah, Shalimar Ahmad, Abdul Rauf |
description | This study compared outcomes of plating distal radius (DR) fractures using wide-awake local anesthesia no tourniquet (WALANT) versus general anesthesia (GA).
From March 2018 to March 2019, 20 patients with DR fracture underwent plating using WALANT whereas 20 patients who underwent plating under GA were used as controls. Outcomes evaluated were pain control, waiting time for the operation, hemodynamic changes, blood loss, the occurrence of adverse effects of medications used in WALANT and GA, and the duration of postoperative stay.
The WALANT group experienced a significantly shorter waiting time for surgery (6 vs 20 days; P < .001) and a shorter postoperative stay (1 vs 2 days; P = .009) compared with the GA group. They also reported mild to no pain during surgery. The groups were similar with regard to blood pressure, blood loss, and operative time. None in the WALANT group required conversion to GA during surgery and no adverse effects were reported.
The WALANT approach is a viable alternative to GA for plating of DR fractures.
Therapeutic III. |
doi_str_mv | 10.1016/j.jhsg.2020.09.003 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8991627</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S2589514120301079</els_id><sourcerecordid>2649995353</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3703-4c5f8eb55c90626306f3c61da43ddacf6c72fefcc8f504e642d80ca5c5b320ab3</originalsourceid><addsrcrecordid>eNp9kU9v1DAQxS0EolXpF-CAfCyHpP4TJzFCSNFCC9KqINjSo-W1J7tesnGxnaJe-8nxakvVXjh5pHnv55l5CL2mpKSE1qebcrOOq5IRRkoiS0L4M3TIRCsLQSv6_FF9gI5j3BBCWCO5YO1LdMBFRYVgzSG6-zbo5MYV_uhi0gP-rq2bIj4L2qQpQMSXcde9chaK7o_-BXjuTdZ1I8S0hug0vvB44acwut8TJHxy1c27i8Vb_BNCzKRzGCE8MbzDHZ75tQ8J_0iTvX2FXvR6iHB8_x6hy7NPi9nnYv71_MusmxeGN4QXlRF9C0shjCQ1qzmpe25qanXFrdWmr03DeuiNaXtBKqgrZltitDBiyRnRS36EPuy519NyC9bAmPJg6jq4rQ63ymunnnZGt1Yrf6NaKWnNmgw4uQcEn3eNSW1dNDAMegQ_RcXqSkopuOBZyvZSE3yMAfqHbyhRu_zURu3yU7v8FJEq55dNbx4P-GD5l1YWvN8LIJ_pxkFQ0TgYDVgXwCRlvfsf_y_p5q3O</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2649995353</pqid></control><display><type>article</type><title>Plating Distal Radius Fractures Using Wide-Awake Local Anesthesia No Tourniquet (WALANT) Versus General Anesthesia: A Cohort Study</title><source>NCBI_PubMed Central(免费)</source><source>ScienceDirect (Online service)</source><creator>Yi, Liew Mei ; Ahmad, Amir Adham ; Ruslan, Shairil Rahayu ; Abdullah, Shalimar ; Ahmad, Abdul Rauf</creator><creatorcontrib>Yi, Liew Mei ; Ahmad, Amir Adham ; Ruslan, Shairil Rahayu ; Abdullah, Shalimar ; Ahmad, Abdul Rauf</creatorcontrib><description>This study compared outcomes of plating distal radius (DR) fractures using wide-awake local anesthesia no tourniquet (WALANT) versus general anesthesia (GA).
From March 2018 to March 2019, 20 patients with DR fracture underwent plating using WALANT whereas 20 patients who underwent plating under GA were used as controls. Outcomes evaluated were pain control, waiting time for the operation, hemodynamic changes, blood loss, the occurrence of adverse effects of medications used in WALANT and GA, and the duration of postoperative stay.
The WALANT group experienced a significantly shorter waiting time for surgery (6 vs 20 days; P < .001) and a shorter postoperative stay (1 vs 2 days; P = .009) compared with the GA group. They also reported mild to no pain during surgery. The groups were similar with regard to blood pressure, blood loss, and operative time. None in the WALANT group required conversion to GA during surgery and no adverse effects were reported.
The WALANT approach is a viable alternative to GA for plating of DR fractures.
Therapeutic III.</description><identifier>ISSN: 2589-5141</identifier><identifier>EISSN: 2589-5141</identifier><identifier>DOI: 10.1016/j.jhsg.2020.09.003</identifier><identifier>PMID: 35415527</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Bleeding ; Lidocaine ; Original Research ; Pain ; Radius</subject><ispartof>Journal of hand surgery global online, 2020-11, Vol.2 (6), p.331-338</ispartof><rights>2020 The Authors</rights><rights>2020 The Authors.</rights><rights>2020 The Authors 2020</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3703-4c5f8eb55c90626306f3c61da43ddacf6c72fefcc8f504e642d80ca5c5b320ab3</citedby><cites>FETCH-LOGICAL-c3703-4c5f8eb55c90626306f3c61da43ddacf6c72fefcc8f504e642d80ca5c5b320ab3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8991627/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S2589514120301079$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,3547,27923,27924,45779,53790,53792</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/35415527$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Yi, Liew Mei</creatorcontrib><creatorcontrib>Ahmad, Amir Adham</creatorcontrib><creatorcontrib>Ruslan, Shairil Rahayu</creatorcontrib><creatorcontrib>Abdullah, Shalimar</creatorcontrib><creatorcontrib>Ahmad, Abdul Rauf</creatorcontrib><title>Plating Distal Radius Fractures Using Wide-Awake Local Anesthesia No Tourniquet (WALANT) Versus General Anesthesia: A Cohort Study</title><title>Journal of hand surgery global online</title><addtitle>J Hand Surg Glob Online</addtitle><description>This study compared outcomes of plating distal radius (DR) fractures using wide-awake local anesthesia no tourniquet (WALANT) versus general anesthesia (GA).
From March 2018 to March 2019, 20 patients with DR fracture underwent plating using WALANT whereas 20 patients who underwent plating under GA were used as controls. Outcomes evaluated were pain control, waiting time for the operation, hemodynamic changes, blood loss, the occurrence of adverse effects of medications used in WALANT and GA, and the duration of postoperative stay.
The WALANT group experienced a significantly shorter waiting time for surgery (6 vs 20 days; P < .001) and a shorter postoperative stay (1 vs 2 days; P = .009) compared with the GA group. They also reported mild to no pain during surgery. The groups were similar with regard to blood pressure, blood loss, and operative time. None in the WALANT group required conversion to GA during surgery and no adverse effects were reported.
The WALANT approach is a viable alternative to GA for plating of DR fractures.
Therapeutic III.</description><subject>Bleeding</subject><subject>Lidocaine</subject><subject>Original Research</subject><subject>Pain</subject><subject>Radius</subject><issn>2589-5141</issn><issn>2589-5141</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kU9v1DAQxS0EolXpF-CAfCyHpP4TJzFCSNFCC9KqINjSo-W1J7tesnGxnaJe-8nxakvVXjh5pHnv55l5CL2mpKSE1qebcrOOq5IRRkoiS0L4M3TIRCsLQSv6_FF9gI5j3BBCWCO5YO1LdMBFRYVgzSG6-zbo5MYV_uhi0gP-rq2bIj4L2qQpQMSXcde9chaK7o_-BXjuTdZ1I8S0hug0vvB44acwut8TJHxy1c27i8Vb_BNCzKRzGCE8MbzDHZ75tQ8J_0iTvX2FXvR6iHB8_x6hy7NPi9nnYv71_MusmxeGN4QXlRF9C0shjCQ1qzmpe25qanXFrdWmr03DeuiNaXtBKqgrZltitDBiyRnRS36EPuy519NyC9bAmPJg6jq4rQ63ymunnnZGt1Yrf6NaKWnNmgw4uQcEn3eNSW1dNDAMegQ_RcXqSkopuOBZyvZSE3yMAfqHbyhRu_zURu3yU7v8FJEq55dNbx4P-GD5l1YWvN8LIJ_pxkFQ0TgYDVgXwCRlvfsf_y_p5q3O</recordid><startdate>20201101</startdate><enddate>20201101</enddate><creator>Yi, Liew Mei</creator><creator>Ahmad, Amir Adham</creator><creator>Ruslan, Shairil Rahayu</creator><creator>Abdullah, Shalimar</creator><creator>Ahmad, Abdul Rauf</creator><general>Elsevier Inc</general><general>Elsevier</general><scope>6I.</scope><scope>AAFTH</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20201101</creationdate><title>Plating Distal Radius Fractures Using Wide-Awake Local Anesthesia No Tourniquet (WALANT) Versus General Anesthesia: A Cohort Study</title><author>Yi, Liew Mei ; Ahmad, Amir Adham ; Ruslan, Shairil Rahayu ; Abdullah, Shalimar ; Ahmad, Abdul Rauf</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3703-4c5f8eb55c90626306f3c61da43ddacf6c72fefcc8f504e642d80ca5c5b320ab3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Bleeding</topic><topic>Lidocaine</topic><topic>Original Research</topic><topic>Pain</topic><topic>Radius</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yi, Liew Mei</creatorcontrib><creatorcontrib>Ahmad, Amir Adham</creatorcontrib><creatorcontrib>Ruslan, Shairil Rahayu</creatorcontrib><creatorcontrib>Abdullah, Shalimar</creatorcontrib><creatorcontrib>Ahmad, Abdul Rauf</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of hand surgery global online</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yi, Liew Mei</au><au>Ahmad, Amir Adham</au><au>Ruslan, Shairil Rahayu</au><au>Abdullah, Shalimar</au><au>Ahmad, Abdul Rauf</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Plating Distal Radius Fractures Using Wide-Awake Local Anesthesia No Tourniquet (WALANT) Versus General Anesthesia: A Cohort Study</atitle><jtitle>Journal of hand surgery global online</jtitle><addtitle>J Hand Surg Glob Online</addtitle><date>2020-11-01</date><risdate>2020</risdate><volume>2</volume><issue>6</issue><spage>331</spage><epage>338</epage><pages>331-338</pages><issn>2589-5141</issn><eissn>2589-5141</eissn><abstract>This study compared outcomes of plating distal radius (DR) fractures using wide-awake local anesthesia no tourniquet (WALANT) versus general anesthesia (GA).
From March 2018 to March 2019, 20 patients with DR fracture underwent plating using WALANT whereas 20 patients who underwent plating under GA were used as controls. Outcomes evaluated were pain control, waiting time for the operation, hemodynamic changes, blood loss, the occurrence of adverse effects of medications used in WALANT and GA, and the duration of postoperative stay.
The WALANT group experienced a significantly shorter waiting time for surgery (6 vs 20 days; P < .001) and a shorter postoperative stay (1 vs 2 days; P = .009) compared with the GA group. They also reported mild to no pain during surgery. The groups were similar with regard to blood pressure, blood loss, and operative time. None in the WALANT group required conversion to GA during surgery and no adverse effects were reported.
The WALANT approach is a viable alternative to GA for plating of DR fractures.
Therapeutic III.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>35415527</pmid><doi>10.1016/j.jhsg.2020.09.003</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2589-5141 |
ispartof | Journal of hand surgery global online, 2020-11, Vol.2 (6), p.331-338 |
issn | 2589-5141 2589-5141 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8991627 |
source | NCBI_PubMed Central(免费); ScienceDirect (Online service) |
subjects | Bleeding Lidocaine Original Research Pain Radius |
title | Plating Distal Radius Fractures Using Wide-Awake Local Anesthesia No Tourniquet (WALANT) Versus General Anesthesia: A Cohort Study |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T03%3A00%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Plating%20Distal%20Radius%20Fractures%20Using%20Wide-Awake%20Local%20Anesthesia%20No%20Tourniquet%20(WALANT)%20Versus%20General%20Anesthesia:%20A%20Cohort%20Study&rft.jtitle=Journal%20of%20hand%20surgery%20global%20online&rft.au=Yi,%20Liew%20Mei&rft.date=2020-11-01&rft.volume=2&rft.issue=6&rft.spage=331&rft.epage=338&rft.pages=331-338&rft.issn=2589-5141&rft.eissn=2589-5141&rft_id=info:doi/10.1016/j.jhsg.2020.09.003&rft_dat=%3Cproquest_pubme%3E2649995353%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3703-4c5f8eb55c90626306f3c61da43ddacf6c72fefcc8f504e642d80ca5c5b320ab3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2649995353&rft_id=info:pmid/35415527&rfr_iscdi=true |