Loading…

Tissue Reactivity to, and Stability of, Glaucoma Drainage Device Materials Placed Under Rabbit Conjunctiva

To evaluate tissue reactivity to, and the stability of, glaucoma drainage device materials placed under rabbit conjunctiva in vivo. Disks (diameter, 3 mm; thickness, ∼0.3 mm) fabricated from poly(styrene-block-isobutylene-block-styrene) (SIBS), silicone, stainless-steel, or glutaraldehyde cross-link...

Full description

Saved in:
Bibliographic Details
Published in:Translational vision science & technology 2022-04, Vol.11 (4), p.9-9
Main Authors: Nakamura, Kenichi, Fujimoto, Tomokazu, Okada, Miho, Maki, Kentaro, Shimazaki, Atsushi, Kato, Masatomo, Inoue, Toshihiro
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c447t-d519e25dfb4992ed63fca4bbc5d8aebae69b20075711a948ee8b42a214d0b2353
cites cdi_FETCH-LOGICAL-c447t-d519e25dfb4992ed63fca4bbc5d8aebae69b20075711a948ee8b42a214d0b2353
container_end_page 9
container_issue 4
container_start_page 9
container_title Translational vision science & technology
container_volume 11
creator Nakamura, Kenichi
Fujimoto, Tomokazu
Okada, Miho
Maki, Kentaro
Shimazaki, Atsushi
Kato, Masatomo
Inoue, Toshihiro
description To evaluate tissue reactivity to, and the stability of, glaucoma drainage device materials placed under rabbit conjunctiva in vivo. Disks (diameter, 3 mm; thickness, ∼0.3 mm) fabricated from poly(styrene-block-isobutylene-block-styrene) (SIBS), silicone, stainless-steel, or glutaraldehyde cross-linked collagen (GACLC) were inserted under rabbit conjunctiva. Conjunctival and scleral sections obtained at 4, 8, and 12 weeks after surgery were immunostained for α-smooth muscle actin (SMA). The ratio of the maximum thickness of the α-SMA-positive conjunctiva to the scleral thickness (α-SMA/S ratio) was calculated. The in vivo stability of the drainage devices at 12 weeks after insertion was evaluated. The mean α-SMA/S ratios of the SIBS and silicone groups were lower than that of the stainless-steel group at 4 weeks after surgery (P < 0.05), and that of the SIBS group was lower than that of the GACLC group (P < 0.05). The ratios at 8 weeks after surgery were lower in the SIBS and silicone groups than in the GACLC group (P < 0.01). The ratios at 12 weeks after surgery were lower in the SIBS and silicone groups than in the GACLC group (P < 0.05). The surface areas of GACLC disks explanted from conjunctivae were significantly lower than that of intact disks (P < 0.01). SIBS and silicon were highly biostable and exhibited less tissue reactivity than GACLC in vivo. Comparisons of materials using animal models can predict the clinical stability and safety of such materials in humans.
doi_str_mv 10.1167/tvst.11.4.9
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_9012888</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2649252151</sourcerecordid><originalsourceid>FETCH-LOGICAL-c447t-d519e25dfb4992ed63fca4bbc5d8aebae69b20075711a948ee8b42a214d0b2353</originalsourceid><addsrcrecordid>eNpVkctLxDAQxoMoKurJu-Qo6K5NmnSbiyC7vkBRfJzDJJlqlm6jSbrgf28XH-hc5mPmxzcDHyH7rBgzVk1O8jLlQY3FWK2Rbc4qMeJSsfU_eovspTQvhqpqKUS1SbZKKQohynqbzJ98Sj3SBwSb_dLnD5rDMYXO0ccMxrerSWiO6WULvQ0LoLMIvoMXpDNceov0FjJGD22i9y1YdPS5cxjpAxjjM52Gbt53K2vYJRvNgOHed98hzxfnT9Or0c3d5fX07GZkhZjkkZNMIZeuMUIpjq4qGwvCGCtdDWgAK2V4UUzkhDFQokasjeDAmXCF4aUsd8jpl-9bbxboLHY5Qqvfol9A_NABvP6_6fyrfglLrQrG67oeDA6_DWJ47zFlvfDJYttCh6FPmldCccmZZAN69IXaGFKK2PyeYYVeBaRXAQ1KC60G-uDvZ7_sTxzlJ3vojnY</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2649252151</pqid></control><display><type>article</type><title>Tissue Reactivity to, and Stability of, Glaucoma Drainage Device Materials Placed Under Rabbit Conjunctiva</title><source>PubMed Central</source><creator>Nakamura, Kenichi ; Fujimoto, Tomokazu ; Okada, Miho ; Maki, Kentaro ; Shimazaki, Atsushi ; Kato, Masatomo ; Inoue, Toshihiro</creator><creatorcontrib>Nakamura, Kenichi ; Fujimoto, Tomokazu ; Okada, Miho ; Maki, Kentaro ; Shimazaki, Atsushi ; Kato, Masatomo ; Inoue, Toshihiro</creatorcontrib><description>To evaluate tissue reactivity to, and the stability of, glaucoma drainage device materials placed under rabbit conjunctiva in vivo. Disks (diameter, 3 mm; thickness, ∼0.3 mm) fabricated from poly(styrene-block-isobutylene-block-styrene) (SIBS), silicone, stainless-steel, or glutaraldehyde cross-linked collagen (GACLC) were inserted under rabbit conjunctiva. Conjunctival and scleral sections obtained at 4, 8, and 12 weeks after surgery were immunostained for α-smooth muscle actin (SMA). The ratio of the maximum thickness of the α-SMA-positive conjunctiva to the scleral thickness (α-SMA/S ratio) was calculated. The in vivo stability of the drainage devices at 12 weeks after insertion was evaluated. The mean α-SMA/S ratios of the SIBS and silicone groups were lower than that of the stainless-steel group at 4 weeks after surgery (P &lt; 0.05), and that of the SIBS group was lower than that of the GACLC group (P &lt; 0.05). The ratios at 8 weeks after surgery were lower in the SIBS and silicone groups than in the GACLC group (P &lt; 0.01). The ratios at 12 weeks after surgery were lower in the SIBS and silicone groups than in the GACLC group (P &lt; 0.05). The surface areas of GACLC disks explanted from conjunctivae were significantly lower than that of intact disks (P &lt; 0.01). SIBS and silicon were highly biostable and exhibited less tissue reactivity than GACLC in vivo. Comparisons of materials using animal models can predict the clinical stability and safety of such materials in humans.</description><identifier>ISSN: 2164-2591</identifier><identifier>EISSN: 2164-2591</identifier><identifier>DOI: 10.1167/tvst.11.4.9</identifier><identifier>PMID: 35404438</identifier><language>eng</language><publisher>United States: The Association for Research in Vision and Ophthalmology</publisher><subject>Animals ; Conjunctiva - surgery ; Glaucoma Drainage Implants ; Rabbits ; Silicones ; Steel ; Styrene</subject><ispartof>Translational vision science &amp; technology, 2022-04, Vol.11 (4), p.9-9</ispartof><rights>Copyright 2022 The Authors 2022</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c447t-d519e25dfb4992ed63fca4bbc5d8aebae69b20075711a948ee8b42a214d0b2353</citedby><cites>FETCH-LOGICAL-c447t-d519e25dfb4992ed63fca4bbc5d8aebae69b20075711a948ee8b42a214d0b2353</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC9012888/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC9012888/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,725,778,782,883,27907,27908,53774,53776</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/35404438$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Nakamura, Kenichi</creatorcontrib><creatorcontrib>Fujimoto, Tomokazu</creatorcontrib><creatorcontrib>Okada, Miho</creatorcontrib><creatorcontrib>Maki, Kentaro</creatorcontrib><creatorcontrib>Shimazaki, Atsushi</creatorcontrib><creatorcontrib>Kato, Masatomo</creatorcontrib><creatorcontrib>Inoue, Toshihiro</creatorcontrib><title>Tissue Reactivity to, and Stability of, Glaucoma Drainage Device Materials Placed Under Rabbit Conjunctiva</title><title>Translational vision science &amp; technology</title><addtitle>Transl Vis Sci Technol</addtitle><description>To evaluate tissue reactivity to, and the stability of, glaucoma drainage device materials placed under rabbit conjunctiva in vivo. Disks (diameter, 3 mm; thickness, ∼0.3 mm) fabricated from poly(styrene-block-isobutylene-block-styrene) (SIBS), silicone, stainless-steel, or glutaraldehyde cross-linked collagen (GACLC) were inserted under rabbit conjunctiva. Conjunctival and scleral sections obtained at 4, 8, and 12 weeks after surgery were immunostained for α-smooth muscle actin (SMA). The ratio of the maximum thickness of the α-SMA-positive conjunctiva to the scleral thickness (α-SMA/S ratio) was calculated. The in vivo stability of the drainage devices at 12 weeks after insertion was evaluated. The mean α-SMA/S ratios of the SIBS and silicone groups were lower than that of the stainless-steel group at 4 weeks after surgery (P &lt; 0.05), and that of the SIBS group was lower than that of the GACLC group (P &lt; 0.05). The ratios at 8 weeks after surgery were lower in the SIBS and silicone groups than in the GACLC group (P &lt; 0.01). The ratios at 12 weeks after surgery were lower in the SIBS and silicone groups than in the GACLC group (P &lt; 0.05). The surface areas of GACLC disks explanted from conjunctivae were significantly lower than that of intact disks (P &lt; 0.01). SIBS and silicon were highly biostable and exhibited less tissue reactivity than GACLC in vivo. Comparisons of materials using animal models can predict the clinical stability and safety of such materials in humans.</description><subject>Animals</subject><subject>Conjunctiva - surgery</subject><subject>Glaucoma Drainage Implants</subject><subject>Rabbits</subject><subject>Silicones</subject><subject>Steel</subject><subject>Styrene</subject><issn>2164-2591</issn><issn>2164-2591</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNpVkctLxDAQxoMoKurJu-Qo6K5NmnSbiyC7vkBRfJzDJJlqlm6jSbrgf28XH-hc5mPmxzcDHyH7rBgzVk1O8jLlQY3FWK2Rbc4qMeJSsfU_eovspTQvhqpqKUS1SbZKKQohynqbzJ98Sj3SBwSb_dLnD5rDMYXO0ccMxrerSWiO6WULvQ0LoLMIvoMXpDNceov0FjJGD22i9y1YdPS5cxjpAxjjM52Gbt53K2vYJRvNgOHed98hzxfnT9Or0c3d5fX07GZkhZjkkZNMIZeuMUIpjq4qGwvCGCtdDWgAK2V4UUzkhDFQokasjeDAmXCF4aUsd8jpl-9bbxboLHY5Qqvfol9A_NABvP6_6fyrfglLrQrG67oeDA6_DWJ47zFlvfDJYttCh6FPmldCccmZZAN69IXaGFKK2PyeYYVeBaRXAQ1KC60G-uDvZ7_sTxzlJ3vojnY</recordid><startdate>20220401</startdate><enddate>20220401</enddate><creator>Nakamura, Kenichi</creator><creator>Fujimoto, Tomokazu</creator><creator>Okada, Miho</creator><creator>Maki, Kentaro</creator><creator>Shimazaki, Atsushi</creator><creator>Kato, Masatomo</creator><creator>Inoue, Toshihiro</creator><general>The Association for Research in Vision and Ophthalmology</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20220401</creationdate><title>Tissue Reactivity to, and Stability of, Glaucoma Drainage Device Materials Placed Under Rabbit Conjunctiva</title><author>Nakamura, Kenichi ; Fujimoto, Tomokazu ; Okada, Miho ; Maki, Kentaro ; Shimazaki, Atsushi ; Kato, Masatomo ; Inoue, Toshihiro</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c447t-d519e25dfb4992ed63fca4bbc5d8aebae69b20075711a948ee8b42a214d0b2353</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Animals</topic><topic>Conjunctiva - surgery</topic><topic>Glaucoma Drainage Implants</topic><topic>Rabbits</topic><topic>Silicones</topic><topic>Steel</topic><topic>Styrene</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nakamura, Kenichi</creatorcontrib><creatorcontrib>Fujimoto, Tomokazu</creatorcontrib><creatorcontrib>Okada, Miho</creatorcontrib><creatorcontrib>Maki, Kentaro</creatorcontrib><creatorcontrib>Shimazaki, Atsushi</creatorcontrib><creatorcontrib>Kato, Masatomo</creatorcontrib><creatorcontrib>Inoue, Toshihiro</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Translational vision science &amp; technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nakamura, Kenichi</au><au>Fujimoto, Tomokazu</au><au>Okada, Miho</au><au>Maki, Kentaro</au><au>Shimazaki, Atsushi</au><au>Kato, Masatomo</au><au>Inoue, Toshihiro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Tissue Reactivity to, and Stability of, Glaucoma Drainage Device Materials Placed Under Rabbit Conjunctiva</atitle><jtitle>Translational vision science &amp; technology</jtitle><addtitle>Transl Vis Sci Technol</addtitle><date>2022-04-01</date><risdate>2022</risdate><volume>11</volume><issue>4</issue><spage>9</spage><epage>9</epage><pages>9-9</pages><issn>2164-2591</issn><eissn>2164-2591</eissn><abstract>To evaluate tissue reactivity to, and the stability of, glaucoma drainage device materials placed under rabbit conjunctiva in vivo. Disks (diameter, 3 mm; thickness, ∼0.3 mm) fabricated from poly(styrene-block-isobutylene-block-styrene) (SIBS), silicone, stainless-steel, or glutaraldehyde cross-linked collagen (GACLC) were inserted under rabbit conjunctiva. Conjunctival and scleral sections obtained at 4, 8, and 12 weeks after surgery were immunostained for α-smooth muscle actin (SMA). The ratio of the maximum thickness of the α-SMA-positive conjunctiva to the scleral thickness (α-SMA/S ratio) was calculated. The in vivo stability of the drainage devices at 12 weeks after insertion was evaluated. The mean α-SMA/S ratios of the SIBS and silicone groups were lower than that of the stainless-steel group at 4 weeks after surgery (P &lt; 0.05), and that of the SIBS group was lower than that of the GACLC group (P &lt; 0.05). The ratios at 8 weeks after surgery were lower in the SIBS and silicone groups than in the GACLC group (P &lt; 0.01). The ratios at 12 weeks after surgery were lower in the SIBS and silicone groups than in the GACLC group (P &lt; 0.05). The surface areas of GACLC disks explanted from conjunctivae were significantly lower than that of intact disks (P &lt; 0.01). SIBS and silicon were highly biostable and exhibited less tissue reactivity than GACLC in vivo. Comparisons of materials using animal models can predict the clinical stability and safety of such materials in humans.</abstract><cop>United States</cop><pub>The Association for Research in Vision and Ophthalmology</pub><pmid>35404438</pmid><doi>10.1167/tvst.11.4.9</doi><tpages>1</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2164-2591
ispartof Translational vision science & technology, 2022-04, Vol.11 (4), p.9-9
issn 2164-2591
2164-2591
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_9012888
source PubMed Central
subjects Animals
Conjunctiva - surgery
Glaucoma Drainage Implants
Rabbits
Silicones
Steel
Styrene
title Tissue Reactivity to, and Stability of, Glaucoma Drainage Device Materials Placed Under Rabbit Conjunctiva
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T22%3A24%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Tissue%20Reactivity%20to,%20and%20Stability%20of,%20Glaucoma%20Drainage%20Device%20Materials%20Placed%20Under%20Rabbit%20Conjunctiva&rft.jtitle=Translational%20vision%20science%20&%20technology&rft.au=Nakamura,%20Kenichi&rft.date=2022-04-01&rft.volume=11&rft.issue=4&rft.spage=9&rft.epage=9&rft.pages=9-9&rft.issn=2164-2591&rft.eissn=2164-2591&rft_id=info:doi/10.1167/tvst.11.4.9&rft_dat=%3Cproquest_pubme%3E2649252151%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c447t-d519e25dfb4992ed63fca4bbc5d8aebae69b20075711a948ee8b42a214d0b2353%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2649252151&rft_id=info:pmid/35404438&rfr_iscdi=true