Loading…

Short-Term Analysis of the Changes in the Bone Mineral Density of the Proximal Femur After Uncemented Total Hip Arthroplasty: A Prospective Study of 110 Patients

Introduction Mechanical loading continuously exposes the bone to remodeling processes. Increased load leads to a gain in bone mass, and reduced load results in a loss. After inserting a prosthesis, the proximal femur is bypassed in loading as the bodyweight shifts distally. This lack of load induces...

Full description

Saved in:
Bibliographic Details
Published in:Curēus (Palo Alto, CA) CA), 2022-03, Vol.14 (3), p.e23257-e23257
Main Authors: Mohanty, Shubhranshu S, Vasavda, Akash N, Rai, Abhishek K, Rathod, Tushar N, Kamble, Prashant, Keny, Swapnil
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c299t-7a355a484f4b813b3f44c7cf9a7863fbc69734219acb75fea1a13e5f0befb5b13
container_end_page e23257
container_issue 3
container_start_page e23257
container_title Curēus (Palo Alto, CA)
container_volume 14
creator Mohanty, Shubhranshu S
Vasavda, Akash N
Rai, Abhishek K
Rathod, Tushar N
Kamble, Prashant
Keny, Swapnil
description Introduction Mechanical loading continuously exposes the bone to remodeling processes. Increased load leads to a gain in bone mass, and reduced load results in a loss. After inserting a prosthesis, the proximal femur is bypassed in loading as the bodyweight shifts distally. This lack of load induces bone resorption according to Wolff's law. To avoid this bone resorption, the implant's bending stiffness should be less than the femoral bone. Dual-energy X-ray absorptiometry (DEXA) is a well-accepted method to measure periprosthetic bone mineral density (BMD) after total hip arthroplasty (THA). Since the strength and durability of the fixation of a femoral prosthesis in cementless hip arthroplasty depend largely on the quantity and quality of the surrounding bone, preoperative and postoperative evaluation of the quantity and quality of the femoral bone is very important in the long-term prognosis of hip arthroplasty. Materials and methods A prospective study of 110 patients in the age group of 25-60 years who underwent uncemented total hip arthroplasty in our tertiary healthcare institution was performed. An uncemented, fully hydroxyapatite-coated implant from a single manufacturer was used in all the patients. All the patients were mobilized on the first post-operative day. The BMD was measured at the proximal femur and the distal tip using a DEXA scan. Gruen zones were used for calculating BMD at different anatomical locations in the femur, with particular importance to zones 1, 4, and 7. Results The pre-operative BMD in all zones measured, viz. zones 1, 4, and zone 7 of the affected side, was found to be significantly lower as compared to the BMD values on the control side (P< 0.05). The mean change in the mean BMD was calculated for all the zones and compared with each other using an unpaired t-test. The mean BMD changes were found to be significantly higher in zone 7 in comparison to both zones 1 and 4 (p
doi_str_mv 10.7759/cureus.23257
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_9013210</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2657644196</sourcerecordid><originalsourceid>FETCH-LOGICAL-c299t-7a355a484f4b813b3f44c7cf9a7863fbc69734219acb75fea1a13e5f0befb5b13</originalsourceid><addsrcrecordid>eNpdkUtv1DAUhSMEolXpjjWyxIYFKX7GCQukMFCKVESlTteW47luXCVxsJ2K-Tn8U9yZtiqs_LjfPfa5pyheE3wipWg-mCXAEk8oo0I-Kw4pqeqyJjV__mR_UBzHeIMxJlhSLPHL4oAJzptKssPiz2XvQyrXEEbUTnrYRheRtyj1gFa9nq4hIjftjp_9BOiHmyDoAX2BKbq0fUAvgv_txnx_CuMSUGsTBHQ1GRhhSrBBa59y8czNqA2pD34edEzbj6i964wzmORuAV2mZbOTJASjC51cbo6vihdWDxGO79ej4ur063p1Vp7__PZ91Z6XhjZNKqVmQmhec8u7mrCOWc6NNLbRsq6Y7UzVSMYpabTppLCgiSYMhMUd2E50hB0Vn_a689KNsDH57WxUzSH7ClvltVP_VibXq2t_qxpMGCU4C7y7Fwj-1wIxqdFFA8OgJ_BLVLQSnNaUCJbRt_-hN34Jefw7Slack6bK1Ps9ZfKMYgD7-BmC1V38ah-_2sWf8TdPDTzCD2Gzv64QrnA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2657644196</pqid></control><display><type>article</type><title>Short-Term Analysis of the Changes in the Bone Mineral Density of the Proximal Femur After Uncemented Total Hip Arthroplasty: A Prospective Study of 110 Patients</title><source>PubMed (Medline)</source><source>Publicly Available Content Database</source><creator>Mohanty, Shubhranshu S ; Vasavda, Akash N ; Rai, Abhishek K ; Rathod, Tushar N ; Kamble, Prashant ; Keny, Swapnil</creator><creatorcontrib>Mohanty, Shubhranshu S ; Vasavda, Akash N ; Rai, Abhishek K ; Rathod, Tushar N ; Kamble, Prashant ; Keny, Swapnil</creatorcontrib><description>Introduction Mechanical loading continuously exposes the bone to remodeling processes. Increased load leads to a gain in bone mass, and reduced load results in a loss. After inserting a prosthesis, the proximal femur is bypassed in loading as the bodyweight shifts distally. This lack of load induces bone resorption according to Wolff's law. To avoid this bone resorption, the implant's bending stiffness should be less than the femoral bone. Dual-energy X-ray absorptiometry (DEXA) is a well-accepted method to measure periprosthetic bone mineral density (BMD) after total hip arthroplasty (THA). Since the strength and durability of the fixation of a femoral prosthesis in cementless hip arthroplasty depend largely on the quantity and quality of the surrounding bone, preoperative and postoperative evaluation of the quantity and quality of the femoral bone is very important in the long-term prognosis of hip arthroplasty. Materials and methods A prospective study of 110 patients in the age group of 25-60 years who underwent uncemented total hip arthroplasty in our tertiary healthcare institution was performed. An uncemented, fully hydroxyapatite-coated implant from a single manufacturer was used in all the patients. All the patients were mobilized on the first post-operative day. The BMD was measured at the proximal femur and the distal tip using a DEXA scan. Gruen zones were used for calculating BMD at different anatomical locations in the femur, with particular importance to zones 1, 4, and 7. Results The pre-operative BMD in all zones measured, viz. zones 1, 4, and zone 7 of the affected side, was found to be significantly lower as compared to the BMD values on the control side (P&lt; 0.05). The mean change in the mean BMD was calculated for all the zones and compared with each other using an unpaired t-test. The mean BMD changes were found to be significantly higher in zone 7 in comparison to both zones 1 and 4 (p&lt;0.05). Conclusion Significant periprosthetic bone loss after uncemented THA in the femur was noted in Gruen zones 1, 4, and 7 during the first six months after THA, with the greatest bone loss in the femoral calcar area (zone 7). The lower the preoperative BMD of the patient, the greater the postoperative bone loss.</description><identifier>ISSN: 2168-8184</identifier><identifier>EISSN: 2168-8184</identifier><identifier>DOI: 10.7759/cureus.23257</identifier><identifier>PMID: 35449673</identifier><language>eng</language><publisher>United States: Cureus Inc</publisher><subject>Age groups ; Bone density ; Joint replacement surgery ; Joint surgery ; Orthopedics ; Prostheses ; Transplants &amp; implants</subject><ispartof>Curēus (Palo Alto, CA), 2022-03, Vol.14 (3), p.e23257-e23257</ispartof><rights>Copyright © 2022, Mohanty et al.</rights><rights>Copyright © 2022, Mohanty et al. This work is published under https://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>Copyright © 2022, Mohanty et al. 2022 Mohanty et al.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c299t-7a355a484f4b813b3f44c7cf9a7863fbc69734219acb75fea1a13e5f0befb5b13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2657644196/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2657644196?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,25753,27924,27925,37012,37013,44590,53791,53793,75126</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/35449673$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mohanty, Shubhranshu S</creatorcontrib><creatorcontrib>Vasavda, Akash N</creatorcontrib><creatorcontrib>Rai, Abhishek K</creatorcontrib><creatorcontrib>Rathod, Tushar N</creatorcontrib><creatorcontrib>Kamble, Prashant</creatorcontrib><creatorcontrib>Keny, Swapnil</creatorcontrib><title>Short-Term Analysis of the Changes in the Bone Mineral Density of the Proximal Femur After Uncemented Total Hip Arthroplasty: A Prospective Study of 110 Patients</title><title>Curēus (Palo Alto, CA)</title><addtitle>Cureus</addtitle><description>Introduction Mechanical loading continuously exposes the bone to remodeling processes. Increased load leads to a gain in bone mass, and reduced load results in a loss. After inserting a prosthesis, the proximal femur is bypassed in loading as the bodyweight shifts distally. This lack of load induces bone resorption according to Wolff's law. To avoid this bone resorption, the implant's bending stiffness should be less than the femoral bone. Dual-energy X-ray absorptiometry (DEXA) is a well-accepted method to measure periprosthetic bone mineral density (BMD) after total hip arthroplasty (THA). Since the strength and durability of the fixation of a femoral prosthesis in cementless hip arthroplasty depend largely on the quantity and quality of the surrounding bone, preoperative and postoperative evaluation of the quantity and quality of the femoral bone is very important in the long-term prognosis of hip arthroplasty. Materials and methods A prospective study of 110 patients in the age group of 25-60 years who underwent uncemented total hip arthroplasty in our tertiary healthcare institution was performed. An uncemented, fully hydroxyapatite-coated implant from a single manufacturer was used in all the patients. All the patients were mobilized on the first post-operative day. The BMD was measured at the proximal femur and the distal tip using a DEXA scan. Gruen zones were used for calculating BMD at different anatomical locations in the femur, with particular importance to zones 1, 4, and 7. Results The pre-operative BMD in all zones measured, viz. zones 1, 4, and zone 7 of the affected side, was found to be significantly lower as compared to the BMD values on the control side (P&lt; 0.05). The mean change in the mean BMD was calculated for all the zones and compared with each other using an unpaired t-test. The mean BMD changes were found to be significantly higher in zone 7 in comparison to both zones 1 and 4 (p&lt;0.05). Conclusion Significant periprosthetic bone loss after uncemented THA in the femur was noted in Gruen zones 1, 4, and 7 during the first six months after THA, with the greatest bone loss in the femoral calcar area (zone 7). The lower the preoperative BMD of the patient, the greater the postoperative bone loss.</description><subject>Age groups</subject><subject>Bone density</subject><subject>Joint replacement surgery</subject><subject>Joint surgery</subject><subject>Orthopedics</subject><subject>Prostheses</subject><subject>Transplants &amp; implants</subject><issn>2168-8184</issn><issn>2168-8184</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNpdkUtv1DAUhSMEolXpjjWyxIYFKX7GCQukMFCKVESlTteW47luXCVxsJ2K-Tn8U9yZtiqs_LjfPfa5pyheE3wipWg-mCXAEk8oo0I-Kw4pqeqyJjV__mR_UBzHeIMxJlhSLPHL4oAJzptKssPiz2XvQyrXEEbUTnrYRheRtyj1gFa9nq4hIjftjp_9BOiHmyDoAX2BKbq0fUAvgv_txnx_CuMSUGsTBHQ1GRhhSrBBa59y8czNqA2pD34edEzbj6i964wzmORuAV2mZbOTJASjC51cbo6vihdWDxGO79ej4ur063p1Vp7__PZ91Z6XhjZNKqVmQmhec8u7mrCOWc6NNLbRsq6Y7UzVSMYpabTppLCgiSYMhMUd2E50hB0Vn_a689KNsDH57WxUzSH7ClvltVP_VibXq2t_qxpMGCU4C7y7Fwj-1wIxqdFFA8OgJ_BLVLQSnNaUCJbRt_-hN34Jefw7Slack6bK1Ps9ZfKMYgD7-BmC1V38ah-_2sWf8TdPDTzCD2Gzv64QrnA</recordid><startdate>20220317</startdate><enddate>20220317</enddate><creator>Mohanty, Shubhranshu S</creator><creator>Vasavda, Akash N</creator><creator>Rai, Abhishek K</creator><creator>Rathod, Tushar N</creator><creator>Kamble, Prashant</creator><creator>Keny, Swapnil</creator><general>Cureus Inc</general><general>Cureus</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20220317</creationdate><title>Short-Term Analysis of the Changes in the Bone Mineral Density of the Proximal Femur After Uncemented Total Hip Arthroplasty: A Prospective Study of 110 Patients</title><author>Mohanty, Shubhranshu S ; Vasavda, Akash N ; Rai, Abhishek K ; Rathod, Tushar N ; Kamble, Prashant ; Keny, Swapnil</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c299t-7a355a484f4b813b3f44c7cf9a7863fbc69734219acb75fea1a13e5f0befb5b13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Age groups</topic><topic>Bone density</topic><topic>Joint replacement surgery</topic><topic>Joint surgery</topic><topic>Orthopedics</topic><topic>Prostheses</topic><topic>Transplants &amp; implants</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mohanty, Shubhranshu S</creatorcontrib><creatorcontrib>Vasavda, Akash N</creatorcontrib><creatorcontrib>Rai, Abhishek K</creatorcontrib><creatorcontrib>Rathod, Tushar N</creatorcontrib><creatorcontrib>Kamble, Prashant</creatorcontrib><creatorcontrib>Keny, Swapnil</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>ProQuest Health and Medical</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Curēus (Palo Alto, CA)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mohanty, Shubhranshu S</au><au>Vasavda, Akash N</au><au>Rai, Abhishek K</au><au>Rathod, Tushar N</au><au>Kamble, Prashant</au><au>Keny, Swapnil</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Short-Term Analysis of the Changes in the Bone Mineral Density of the Proximal Femur After Uncemented Total Hip Arthroplasty: A Prospective Study of 110 Patients</atitle><jtitle>Curēus (Palo Alto, CA)</jtitle><addtitle>Cureus</addtitle><date>2022-03-17</date><risdate>2022</risdate><volume>14</volume><issue>3</issue><spage>e23257</spage><epage>e23257</epage><pages>e23257-e23257</pages><issn>2168-8184</issn><eissn>2168-8184</eissn><abstract>Introduction Mechanical loading continuously exposes the bone to remodeling processes. Increased load leads to a gain in bone mass, and reduced load results in a loss. After inserting a prosthesis, the proximal femur is bypassed in loading as the bodyweight shifts distally. This lack of load induces bone resorption according to Wolff's law. To avoid this bone resorption, the implant's bending stiffness should be less than the femoral bone. Dual-energy X-ray absorptiometry (DEXA) is a well-accepted method to measure periprosthetic bone mineral density (BMD) after total hip arthroplasty (THA). Since the strength and durability of the fixation of a femoral prosthesis in cementless hip arthroplasty depend largely on the quantity and quality of the surrounding bone, preoperative and postoperative evaluation of the quantity and quality of the femoral bone is very important in the long-term prognosis of hip arthroplasty. Materials and methods A prospective study of 110 patients in the age group of 25-60 years who underwent uncemented total hip arthroplasty in our tertiary healthcare institution was performed. An uncemented, fully hydroxyapatite-coated implant from a single manufacturer was used in all the patients. All the patients were mobilized on the first post-operative day. The BMD was measured at the proximal femur and the distal tip using a DEXA scan. Gruen zones were used for calculating BMD at different anatomical locations in the femur, with particular importance to zones 1, 4, and 7. Results The pre-operative BMD in all zones measured, viz. zones 1, 4, and zone 7 of the affected side, was found to be significantly lower as compared to the BMD values on the control side (P&lt; 0.05). The mean change in the mean BMD was calculated for all the zones and compared with each other using an unpaired t-test. The mean BMD changes were found to be significantly higher in zone 7 in comparison to both zones 1 and 4 (p&lt;0.05). Conclusion Significant periprosthetic bone loss after uncemented THA in the femur was noted in Gruen zones 1, 4, and 7 during the first six months after THA, with the greatest bone loss in the femoral calcar area (zone 7). The lower the preoperative BMD of the patient, the greater the postoperative bone loss.</abstract><cop>United States</cop><pub>Cureus Inc</pub><pmid>35449673</pmid><doi>10.7759/cureus.23257</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2168-8184
ispartof Curēus (Palo Alto, CA), 2022-03, Vol.14 (3), p.e23257-e23257
issn 2168-8184
2168-8184
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_9013210
source PubMed (Medline); Publicly Available Content Database
subjects Age groups
Bone density
Joint replacement surgery
Joint surgery
Orthopedics
Prostheses
Transplants & implants
title Short-Term Analysis of the Changes in the Bone Mineral Density of the Proximal Femur After Uncemented Total Hip Arthroplasty: A Prospective Study of 110 Patients
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-30T21%3A53%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Short-Term%20Analysis%20of%20the%20Changes%20in%20the%20Bone%20Mineral%20Density%20of%20the%20Proximal%20Femur%20After%20Uncemented%20Total%20Hip%20Arthroplasty:%20A%20Prospective%20Study%20of%20110%20Patients&rft.jtitle=Cur%C4%93us%20(Palo%20Alto,%20CA)&rft.au=Mohanty,%20Shubhranshu%20S&rft.date=2022-03-17&rft.volume=14&rft.issue=3&rft.spage=e23257&rft.epage=e23257&rft.pages=e23257-e23257&rft.issn=2168-8184&rft.eissn=2168-8184&rft_id=info:doi/10.7759/cureus.23257&rft_dat=%3Cproquest_pubme%3E2657644196%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c299t-7a355a484f4b813b3f44c7cf9a7863fbc69734219acb75fea1a13e5f0befb5b13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2657644196&rft_id=info:pmid/35449673&rfr_iscdi=true