Pharmaceutical analysis by NMR can accommodate strict impurity thresholds: The case of choline
The ICH guidelines recommend reporting thresholds for regular impurities in drug substances at the level of 0.05% or 0.03% (w/w) depending on the maximum daily intake. Therefore, any instrumental method of analysis applicable to the impurity analysis should be able to detect and quantify the analyte...
Saved in:
Published in: | Journal of pharmaceutical and biomedical analysis 2022-05, Vol.214, p.114709-114709, Article 114709 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The ICH guidelines recommend reporting thresholds for regular impurities in drug substances at the level of 0.05% or 0.03% (w/w) depending on the maximum daily intake. Therefore, any instrumental method of analysis applicable to the impurity analysis should be able to detect and quantify the analytes at those levels. This investigation was designed to verify the suitability of 1H NMR spectroscopy for the detection of impurities, as a first step in the process before attempting quantification. In order to minimize demand on equipment, this study employed a 400 MHz instrument for structural confirmation and signal assignments of choline (1) and O-(2-hydroxyethyl)choline (2), a known impurity. The limit of detection (LOD) of 2 in 10 mg of 1 was established as 0.01% on a 400 MHz instrument and 2% on a 60 MHz (benchtop) NMR spectrometer. Thus, impurities for which quantification is required are readily detected at 400 MHz or above. These results are in contrast to the widespread belief that 1H NMR sensitivity is insufficient for pharmaceutical impurity analysis. The choice of solvent was recognized as a critical parameter for 1H NMR LOD analysis. Furthermore, publicly available NMR raw data (HMDB) proved to be valuable for unveiling the otherwise cryptic information hidden in complex signal patterns via 1H NMR iterative Full Spin Analysis. Finally, the study uncovered the less noticed, yet characteristic, 14N–1H coupling in the -N+(CH3)3 groups, adding strong arguments for the Raw NMR Data Initiative. Collectively, the data prove that the analytical capabilities of high-field NMR easily fulfill the ICH requirements for detection of impurity in the presence of an actual substance of interest which makes it a step closer to achieving regulatory standards.
•The LOD of choline RCA in choline is |
---|---|
ISSN: | 0731-7085 1873-264X |
DOI: | 10.1016/j.jpba.2022.114709 |