Impact of Femoral Neck Cortical Bone Defect Induced by Core Decompression on Postoperative Stability: A Finite Element Analysis

Objective. To analyze the impact of femoral neck cortical bone defect induced by core decompression on postoperative biomechanical stability using the finite element method. Methods. Five finite element models (FEMs) were established, including the standard operating model and four models of cortica...

Full description

Saved in:
Bibliographic Details
Published in:BioMed research international 2022-05, Vol.2022, p.3667891-13
Main Authors: Yuan, Daizhu, Wu, Zhanyu, Luo, Siwei, Zou, Qiang, Zou, Zihao, Ye, Chuan
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Objective. To analyze the impact of femoral neck cortical bone defect induced by core decompression on postoperative biomechanical stability using the finite element method. Methods. Five finite element models (FEMs) were established, including the standard operating model and four models of cortical bone defects at different portions of the femoral neck (anterior, posterior, superior, and inferior). The maximum stress of the proximal femur was evaluated during normal walking and walking downstairs. Results. Under both weight-bearing conditions, the maximum stress values of the five models were as follows: femoral neck (inferior) > femoral neck (superior) > femoral neck (posterior) > femoral neck (anterior) > standard operation. Stress concentration occurred in the areas of femoral neck cortical bone defect. Under normal walking, the maximum stress of four bone defect models and its increased percentage comparing the standard operation were as follows: anterior (17.17%), posterior (39.02%), superior (57.48%), and inferior (76.42%). The maximum stress was less than the cortical bone yield strength under normal walking conditions. Under walking downstairs, the maximum stress of four bone defect models and its increased percentage comparing the standard operation under normal walking were as follows: anterior (36.75%), posterior (67.82%), superior (83.31%), and inferior (103.65%). Under walking downstairs conditions, the maximum stress of bone defect models (anterior, posterior, and superior) was less than the yield strength of cortical bone, while the maximum stress of bone defect model (inferior) excessed yield strength value. Conclusions. The femoral neck cortical bone defect induced by core decompression can carry out normal walking after surgery. To avoid an increased risk of fracture after surgery, walking downstairs should be avoided when the cortical bone defect is inferior to the femoral neck except for the other three positions (anterior, posterior, and superior).
ISSN:2314-6133
2314-6141