Loading…

Complications Associated with Polydek Sutures Used in the Eyelid Lateral Tarsal Strip Procedures

Suture-related complications can occur in response to a patient's immune system activation regardless of surgical site. However, there is minimal literature describing complications related to commonly used Polydek sutures. We report the diagnosis, treatment, and follow up of four cases of Poly...

Full description

Saved in:
Bibliographic Details
Published in:Clinical medicine & research 2022-06, Vol.20 (2), p.107-110
Main Authors: Chen, Lin, Penne, Robert B
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Suture-related complications can occur in response to a patient's immune system activation regardless of surgical site. However, there is minimal literature describing complications related to commonly used Polydek sutures. We report the diagnosis, treatment, and follow up of four cases of Polydek suture-related complications post-eyelid lateral tarsal strip procedures, including an early wound healing problem/infection and later granuloma formation and/or suture extrusion that only resolved after removal of the Polydek suture or granuloma tissue. Use of non-Polydek sutures may reduce the likelihood for post-operative suture complications.
ISSN:1539-4182
1554-6179
DOI:10.3121/cmr.2021.1661