CArdiac and REspiratory adaptive Computed Tomography (CARE-CT): a proof-of-concept digital phantom study
Current respiratory 4DCT imaging for high-dose rate thoracic radiotherapy treatments are negatively affected by the complex interaction of cardiac and respiratory motion. We propose an imaging method to reduce artifacts caused by thoracic motion, CArdiac and REspiratory adaptive CT (CARE-CT), that m...
Saved in:
Published in: | Physical and engineering sciences in medicine 2022-12, Vol.45 (4), p.1257-1271 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c404t-5be2918e8d269f302b63ac35da23c98b409e533ce613eb500ec60ab27c6db9e23 |
---|---|
cites | cdi_FETCH-LOGICAL-c404t-5be2918e8d269f302b63ac35da23c98b409e533ce613eb500ec60ab27c6db9e23 |
container_end_page | 1271 |
container_issue | 4 |
container_start_page | 1257 |
container_title | Physical and engineering sciences in medicine |
container_volume | 45 |
creator | Morton, Natasha Keall, Paul O’Brien, Ricky Reynolds, Tess |
description | Current respiratory 4DCT imaging for high-dose rate thoracic radiotherapy treatments are negatively affected by the complex interaction of cardiac and respiratory motion. We propose an imaging method to reduce artifacts caused by thoracic motion, CArdiac and REspiratory adaptive CT (CARE-CT), that monitors respiratory motion and ECG signals in real-time, triggering CT acquisition during combined cardiac and respiratory bins. Using a digital phantom, conventional 4DCT and CARE-CT acquisitions for nineteen patient-measured physiological traces were simulated. Ten respiratory bins were acquired for conventional 4DCT scans and ten respiratory bins during cardiac diastole were acquired for CARE-CT scans. Image artifacts were quantified for 10 common thoracic organs at risk (OAR) substructures using the differential normalized cross correlation between axial slices (ΔNCC), mean squared error (MSE) and sensitivity. For all images, on average, CARE-CT improved the ΔNCC for 18/19 and the MSE and sensitivity for all patient traces. The ΔNCC was reduced for all cardiac OARs (mean reduction 21%). The MSE was reduced for all OARs (mean reduction 36%). In the digital phantom study, the average scan time was increased from 1.8 ± 0.4 min to 7.5 ± 2.2 min with a reduction in average beam on time from 98 ± 28 s to 45 s using CARE-CT compared to conventional 4DCT. The proof-of-concept study indicates the potential for CARE-CT to image the thorax in real-time during the cardiac and respiratory cycle simultaneously, to reduce image artifacts for common thoracic OARs. |
doi_str_mv | 10.1007/s13246-022-01193-5 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_9747864</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2740506402</sourcerecordid><originalsourceid>FETCH-LOGICAL-c404t-5be2918e8d269f302b63ac35da23c98b409e533ce613eb500ec60ab27c6db9e23</originalsourceid><addsrcrecordid>eNp9kU1rGzEQhkVpaIKbP9BD0TE9qBl9rreHglncNhAIBOcstJJsK-yutpI24H-fTZ2a9hIYmIF5551hHoQ-UfhKAarrTDkTigBjBCitOZHv0AVTihFR8er9qWb1ObrM-REAmKS0UvIDOudKcMGAXqB9s0ouGIvN4PD9Oo8hmRLTARtnxhKePG5iP07FO7yJfdwlM-4P-KpZ3a9Js_nyDRs8phi3ZA4bB-vHgl3YhWI6PO7NUGKPc5nc4SM625ou-8vXvEAPP9ab5he5vft506xuiRUgCpGtZzVd-qVjqt5yYK3ixnLpDOO2XrYCai85t15R7lsJ4K0C07LKKtfWnvEF-n70Hae29876oSTT6TGF3qSDjibo_ztD2OtdfNJ1Jarl_JcFuno1SPH35HPRfcjWd50ZfJyyZpUACUrAyy52lNoUc05-e1pDQb9Q0kdKeqak_1DSch76_O-Bp5G_TGYBPwry3Bp2PunHOKVhftpbts_Mq533</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2740506402</pqid></control><display><type>article</type><title>CArdiac and REspiratory adaptive Computed Tomography (CARE-CT): a proof-of-concept digital phantom study</title><source>Springer Nature</source><creator>Morton, Natasha ; Keall, Paul ; O’Brien, Ricky ; Reynolds, Tess</creator><creatorcontrib>Morton, Natasha ; Keall, Paul ; O’Brien, Ricky ; Reynolds, Tess</creatorcontrib><description>Current respiratory 4DCT imaging for high-dose rate thoracic radiotherapy treatments are negatively affected by the complex interaction of cardiac and respiratory motion. We propose an imaging method to reduce artifacts caused by thoracic motion, CArdiac and REspiratory adaptive CT (CARE-CT), that monitors respiratory motion and ECG signals in real-time, triggering CT acquisition during combined cardiac and respiratory bins. Using a digital phantom, conventional 4DCT and CARE-CT acquisitions for nineteen patient-measured physiological traces were simulated. Ten respiratory bins were acquired for conventional 4DCT scans and ten respiratory bins during cardiac diastole were acquired for CARE-CT scans. Image artifacts were quantified for 10 common thoracic organs at risk (OAR) substructures using the differential normalized cross correlation between axial slices (ΔNCC), mean squared error (MSE) and sensitivity. For all images, on average, CARE-CT improved the ΔNCC for 18/19 and the MSE and sensitivity for all patient traces. The ΔNCC was reduced for all cardiac OARs (mean reduction 21%). The MSE was reduced for all OARs (mean reduction 36%). In the digital phantom study, the average scan time was increased from 1.8 ± 0.4 min to 7.5 ± 2.2 min with a reduction in average beam on time from 98 ± 28 s to 45 s using CARE-CT compared to conventional 4DCT. The proof-of-concept study indicates the potential for CARE-CT to image the thorax in real-time during the cardiac and respiratory cycle simultaneously, to reduce image artifacts for common thoracic OARs.</description><identifier>ISSN: 2662-4729</identifier><identifier>EISSN: 2662-4737</identifier><identifier>DOI: 10.1007/s13246-022-01193-5</identifier><identifier>PMID: 36434201</identifier><language>eng</language><publisher>Cham: Springer International Publishing</publisher><subject>Biological and Medical Physics ; Biomedical and Life Sciences ; Biomedical Engineering and Bioengineering ; Biomedicine ; Biophysics ; Four-Dimensional Computed Tomography - methods ; Humans ; Medical and Radiation Physics ; Motion ; Phantoms, Imaging ; Respiration ; Scientific Paper</subject><ispartof>Physical and engineering sciences in medicine, 2022-12, Vol.45 (4), p.1257-1271</ispartof><rights>The Author(s) 2022</rights><rights>2022. The Author(s).</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c404t-5be2918e8d269f302b63ac35da23c98b409e533ce613eb500ec60ab27c6db9e23</citedby><cites>FETCH-LOGICAL-c404t-5be2918e8d269f302b63ac35da23c98b409e533ce613eb500ec60ab27c6db9e23</cites><orcidid>0000-0003-0543-9170 ; 0000-0003-4803-6507 ; 0000-0002-6586-7356</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36434201$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Morton, Natasha</creatorcontrib><creatorcontrib>Keall, Paul</creatorcontrib><creatorcontrib>O’Brien, Ricky</creatorcontrib><creatorcontrib>Reynolds, Tess</creatorcontrib><title>CArdiac and REspiratory adaptive Computed Tomography (CARE-CT): a proof-of-concept digital phantom study</title><title>Physical and engineering sciences in medicine</title><addtitle>Phys Eng Sci Med</addtitle><addtitle>Phys Eng Sci Med</addtitle><description>Current respiratory 4DCT imaging for high-dose rate thoracic radiotherapy treatments are negatively affected by the complex interaction of cardiac and respiratory motion. We propose an imaging method to reduce artifacts caused by thoracic motion, CArdiac and REspiratory adaptive CT (CARE-CT), that monitors respiratory motion and ECG signals in real-time, triggering CT acquisition during combined cardiac and respiratory bins. Using a digital phantom, conventional 4DCT and CARE-CT acquisitions for nineteen patient-measured physiological traces were simulated. Ten respiratory bins were acquired for conventional 4DCT scans and ten respiratory bins during cardiac diastole were acquired for CARE-CT scans. Image artifacts were quantified for 10 common thoracic organs at risk (OAR) substructures using the differential normalized cross correlation between axial slices (ΔNCC), mean squared error (MSE) and sensitivity. For all images, on average, CARE-CT improved the ΔNCC for 18/19 and the MSE and sensitivity for all patient traces. The ΔNCC was reduced for all cardiac OARs (mean reduction 21%). The MSE was reduced for all OARs (mean reduction 36%). In the digital phantom study, the average scan time was increased from 1.8 ± 0.4 min to 7.5 ± 2.2 min with a reduction in average beam on time from 98 ± 28 s to 45 s using CARE-CT compared to conventional 4DCT. The proof-of-concept study indicates the potential for CARE-CT to image the thorax in real-time during the cardiac and respiratory cycle simultaneously, to reduce image artifacts for common thoracic OARs.</description><subject>Biological and Medical Physics</subject><subject>Biomedical and Life Sciences</subject><subject>Biomedical Engineering and Bioengineering</subject><subject>Biomedicine</subject><subject>Biophysics</subject><subject>Four-Dimensional Computed Tomography - methods</subject><subject>Humans</subject><subject>Medical and Radiation Physics</subject><subject>Motion</subject><subject>Phantoms, Imaging</subject><subject>Respiration</subject><subject>Scientific Paper</subject><issn>2662-4729</issn><issn>2662-4737</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kU1rGzEQhkVpaIKbP9BD0TE9qBl9rreHglncNhAIBOcstJJsK-yutpI24H-fTZ2a9hIYmIF5551hHoQ-UfhKAarrTDkTigBjBCitOZHv0AVTihFR8er9qWb1ObrM-REAmKS0UvIDOudKcMGAXqB9s0ouGIvN4PD9Oo8hmRLTARtnxhKePG5iP07FO7yJfdwlM-4P-KpZ3a9Js_nyDRs8phi3ZA4bB-vHgl3YhWI6PO7NUGKPc5nc4SM625ou-8vXvEAPP9ab5he5vft506xuiRUgCpGtZzVd-qVjqt5yYK3ixnLpDOO2XrYCai85t15R7lsJ4K0C07LKKtfWnvEF-n70Hae29876oSTT6TGF3qSDjibo_ztD2OtdfNJ1Jarl_JcFuno1SPH35HPRfcjWd50ZfJyyZpUACUrAyy52lNoUc05-e1pDQb9Q0kdKeqak_1DSch76_O-Bp5G_TGYBPwry3Bp2PunHOKVhftpbts_Mq533</recordid><startdate>20221201</startdate><enddate>20221201</enddate><creator>Morton, Natasha</creator><creator>Keall, Paul</creator><creator>O’Brien, Ricky</creator><creator>Reynolds, Tess</creator><general>Springer International Publishing</general><scope>C6C</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0003-0543-9170</orcidid><orcidid>https://orcid.org/0000-0003-4803-6507</orcidid><orcidid>https://orcid.org/0000-0002-6586-7356</orcidid></search><sort><creationdate>20221201</creationdate><title>CArdiac and REspiratory adaptive Computed Tomography (CARE-CT): a proof-of-concept digital phantom study</title><author>Morton, Natasha ; Keall, Paul ; O’Brien, Ricky ; Reynolds, Tess</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c404t-5be2918e8d269f302b63ac35da23c98b409e533ce613eb500ec60ab27c6db9e23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Biological and Medical Physics</topic><topic>Biomedical and Life Sciences</topic><topic>Biomedical Engineering and Bioengineering</topic><topic>Biomedicine</topic><topic>Biophysics</topic><topic>Four-Dimensional Computed Tomography - methods</topic><topic>Humans</topic><topic>Medical and Radiation Physics</topic><topic>Motion</topic><topic>Phantoms, Imaging</topic><topic>Respiration</topic><topic>Scientific Paper</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Morton, Natasha</creatorcontrib><creatorcontrib>Keall, Paul</creatorcontrib><creatorcontrib>O’Brien, Ricky</creatorcontrib><creatorcontrib>Reynolds, Tess</creatorcontrib><collection>SpringerOpen</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Physical and engineering sciences in medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Morton, Natasha</au><au>Keall, Paul</au><au>O’Brien, Ricky</au><au>Reynolds, Tess</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>CArdiac and REspiratory adaptive Computed Tomography (CARE-CT): a proof-of-concept digital phantom study</atitle><jtitle>Physical and engineering sciences in medicine</jtitle><stitle>Phys Eng Sci Med</stitle><addtitle>Phys Eng Sci Med</addtitle><date>2022-12-01</date><risdate>2022</risdate><volume>45</volume><issue>4</issue><spage>1257</spage><epage>1271</epage><pages>1257-1271</pages><issn>2662-4729</issn><eissn>2662-4737</eissn><abstract>Current respiratory 4DCT imaging for high-dose rate thoracic radiotherapy treatments are negatively affected by the complex interaction of cardiac and respiratory motion. We propose an imaging method to reduce artifacts caused by thoracic motion, CArdiac and REspiratory adaptive CT (CARE-CT), that monitors respiratory motion and ECG signals in real-time, triggering CT acquisition during combined cardiac and respiratory bins. Using a digital phantom, conventional 4DCT and CARE-CT acquisitions for nineteen patient-measured physiological traces were simulated. Ten respiratory bins were acquired for conventional 4DCT scans and ten respiratory bins during cardiac diastole were acquired for CARE-CT scans. Image artifacts were quantified for 10 common thoracic organs at risk (OAR) substructures using the differential normalized cross correlation between axial slices (ΔNCC), mean squared error (MSE) and sensitivity. For all images, on average, CARE-CT improved the ΔNCC for 18/19 and the MSE and sensitivity for all patient traces. The ΔNCC was reduced for all cardiac OARs (mean reduction 21%). The MSE was reduced for all OARs (mean reduction 36%). In the digital phantom study, the average scan time was increased from 1.8 ± 0.4 min to 7.5 ± 2.2 min with a reduction in average beam on time from 98 ± 28 s to 45 s using CARE-CT compared to conventional 4DCT. The proof-of-concept study indicates the potential for CARE-CT to image the thorax in real-time during the cardiac and respiratory cycle simultaneously, to reduce image artifacts for common thoracic OARs.</abstract><cop>Cham</cop><pub>Springer International Publishing</pub><pmid>36434201</pmid><doi>10.1007/s13246-022-01193-5</doi><tpages>15</tpages><orcidid>https://orcid.org/0000-0003-0543-9170</orcidid><orcidid>https://orcid.org/0000-0003-4803-6507</orcidid><orcidid>https://orcid.org/0000-0002-6586-7356</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2662-4729 |
ispartof | Physical and engineering sciences in medicine, 2022-12, Vol.45 (4), p.1257-1271 |
issn | 2662-4729 2662-4737 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_9747864 |
source | Springer Nature |
subjects | Biological and Medical Physics Biomedical and Life Sciences Biomedical Engineering and Bioengineering Biomedicine Biophysics Four-Dimensional Computed Tomography - methods Humans Medical and Radiation Physics Motion Phantoms, Imaging Respiration Scientific Paper |
title | CArdiac and REspiratory adaptive Computed Tomography (CARE-CT): a proof-of-concept digital phantom study |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T22%3A03%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=CArdiac%20and%20REspiratory%20adaptive%20Computed%20Tomography%20(CARE-CT):%20a%20proof-of-concept%20digital%20phantom%20study&rft.jtitle=Physical%20and%20engineering%20sciences%20in%20medicine&rft.au=Morton,%20Natasha&rft.date=2022-12-01&rft.volume=45&rft.issue=4&rft.spage=1257&rft.epage=1271&rft.pages=1257-1271&rft.issn=2662-4729&rft.eissn=2662-4737&rft_id=info:doi/10.1007/s13246-022-01193-5&rft_dat=%3Cproquest_pubme%3E2740506402%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c404t-5be2918e8d269f302b63ac35da23c98b409e533ce613eb500ec60ab27c6db9e23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2740506402&rft_id=info:pmid/36434201&rfr_iscdi=true |