Loading…
An all-digital coincidence-selection and coincidence-trigger generation for a small animal RPC-PET camera
The time resolution for gamma photon pairs of a detector based on resistive plate chamber technology is close to 300 ps FWHM. This allows a tight time window for coincidence detection, reducing the number of random coincidences observed and the overall noise of the acquired image. We implemented, in...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 914 |
container_issue | |
container_start_page | 910 |
container_title | |
container_volume | |
creator | Clemencio, F. C. Loureiro, C. F. M. Landeck, J. |
description | The time resolution for gamma photon pairs of a detector based on resistive plate chamber technology is close to 300 ps FWHM. This allows a tight time window for coincidence detection, reducing the number of random coincidences observed and the overall noise of the acquired image. We implemented, inside a Xilinx Virtex-5 field programmable gate array, a fully programmable coincidence-trigger system with sub-nanosecond resolution and low latency for a small animal RPC-PET camera being built. An automatic procedure to construct a histogram of coincidences was implemented that helps characterizing the camera and allows compensating for different delays in the time channels. The time window for coincidences can then be placed at the optimal position helping rejecting coincidences from undesired sources. |
doi_str_mv | 10.1109/NSSMIC.2011.6154569 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>rcaap_6IE</sourceid><recordid>TN_cdi_rcaap_revistas_10400_22_12921</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6154569</ieee_id><sourcerecordid>10400_22_12921</sourcerecordid><originalsourceid>FETCH-LOGICAL-i249t-a3d212469daa52edb24e6486e1d4c884428d0ebd26292f70af2f2f990d99c9f53</originalsourceid><addsrcrecordid>eNpVkE9LAzEQxeM_sNZ-gl724DU1mU2ym2NZqhaqFlvPS5rMLpHttiSL4Lc3WBGcOTyY95vHMIRMOZtxzvT9y2bzvKxmwDifKS6FVPqM3HChipxxYPKcjEAWBWUl6Is_g5f5JRnxNKS5kuKaTGL8YKmU0kLIEfHzPjNdR51v_WC6zB58b73D3iKN2KEd_CERvfvnDMG3LYasxR6D-UGaQ8hMFvcpLOE-afa2ruh6sc2s2Sfqllw1pos4-dUxeX9YbKsnunp9XFbzFfUg9EBN7oCDUNoZIwHdDgQqUSrkTtiyFAJKx3DnQIGGpmCmgdRaM6e11Y3Mx-TulBusMcc64KePg4k1Z4KxGqDmaZEnbHrCPCLWx5AuDl_172fzb1sKZ74</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>An all-digital coincidence-selection and coincidence-trigger generation for a small animal RPC-PET camera</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Clemencio, F. C. ; Loureiro, C. F. M. ; Landeck, J.</creator><creatorcontrib>Clemencio, F. C. ; Loureiro, C. F. M. ; Landeck, J.</creatorcontrib><description>The time resolution for gamma photon pairs of a detector based on resistive plate chamber technology is close to 300 ps FWHM. This allows a tight time window for coincidence detection, reducing the number of random coincidences observed and the overall noise of the acquired image. We implemented, inside a Xilinx Virtex-5 field programmable gate array, a fully programmable coincidence-trigger system with sub-nanosecond resolution and low latency for a small animal RPC-PET camera being built. An automatic procedure to construct a histogram of coincidences was implemented that helps characterizing the camera and allows compensating for different delays in the time channels. The time window for coincidences can then be placed at the optimal position helping rejecting coincidences from undesired sources.</description><identifier>ISSN: 1082-3654</identifier><identifier>ISBN: 1467301183</identifier><identifier>ISBN: 9781467301183</identifier><identifier>ISBN: 1467301205</identifier><identifier>ISBN: 9781467301206</identifier><identifier>EISSN: 2577-0829</identifier><identifier>EISBN: 1467301205</identifier><identifier>EISBN: 1467301191</identifier><identifier>EISBN: 9781467301206</identifier><identifier>EISBN: 9781467301190</identifier><identifier>DOI: 10.1109/NSSMIC.2011.6154569</identifier><language>eng</language><publisher>IEEE</publisher><subject>Acceleration ; Cameras ; Documentation ; Fires</subject><ispartof>2011 IEEE Nuclear Science Symposium Conference Record, 2011, p.910-914</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><orcidid>0000-0003-0453-1151</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6154569$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2056,27923,54553,54918,54930</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6154569$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Clemencio, F. C.</creatorcontrib><creatorcontrib>Loureiro, C. F. M.</creatorcontrib><creatorcontrib>Landeck, J.</creatorcontrib><title>An all-digital coincidence-selection and coincidence-trigger generation for a small animal RPC-PET camera</title><title>2011 IEEE Nuclear Science Symposium Conference Record</title><addtitle>NSSMIC</addtitle><description>The time resolution for gamma photon pairs of a detector based on resistive plate chamber technology is close to 300 ps FWHM. This allows a tight time window for coincidence detection, reducing the number of random coincidences observed and the overall noise of the acquired image. We implemented, inside a Xilinx Virtex-5 field programmable gate array, a fully programmable coincidence-trigger system with sub-nanosecond resolution and low latency for a small animal RPC-PET camera being built. An automatic procedure to construct a histogram of coincidences was implemented that helps characterizing the camera and allows compensating for different delays in the time channels. The time window for coincidences can then be placed at the optimal position helping rejecting coincidences from undesired sources.</description><subject>Acceleration</subject><subject>Cameras</subject><subject>Documentation</subject><subject>Fires</subject><issn>1082-3654</issn><issn>2577-0829</issn><isbn>1467301183</isbn><isbn>9781467301183</isbn><isbn>1467301205</isbn><isbn>9781467301206</isbn><isbn>1467301205</isbn><isbn>1467301191</isbn><isbn>9781467301206</isbn><isbn>9781467301190</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2011</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNpVkE9LAzEQxeM_sNZ-gl724DU1mU2ym2NZqhaqFlvPS5rMLpHttiSL4Lc3WBGcOTyY95vHMIRMOZtxzvT9y2bzvKxmwDifKS6FVPqM3HChipxxYPKcjEAWBWUl6Is_g5f5JRnxNKS5kuKaTGL8YKmU0kLIEfHzPjNdR51v_WC6zB58b73D3iKN2KEd_CERvfvnDMG3LYasxR6D-UGaQ8hMFvcpLOE-afa2ruh6sc2s2Sfqllw1pos4-dUxeX9YbKsnunp9XFbzFfUg9EBN7oCDUNoZIwHdDgQqUSrkTtiyFAJKx3DnQIGGpmCmgdRaM6e11Y3Mx-TulBusMcc64KePg4k1Z4KxGqDmaZEnbHrCPCLWx5AuDl_172fzb1sKZ74</recordid><startdate>20110101</startdate><enddate>20110101</enddate><creator>Clemencio, F. C.</creator><creator>Loureiro, C. F. M.</creator><creator>Landeck, J.</creator><general>IEEE</general><general>Institute of Electrical and Electronics Engineers</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope><scope>RCLKO</scope><orcidid>https://orcid.org/0000-0003-0453-1151</orcidid></search><sort><creationdate>20110101</creationdate><title>An all-digital coincidence-selection and coincidence-trigger generation for a small animal RPC-PET camera</title><author>Clemencio, F. C. ; Loureiro, C. F. M. ; Landeck, J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i249t-a3d212469daa52edb24e6486e1d4c884428d0ebd26292f70af2f2f990d99c9f53</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Acceleration</topic><topic>Cameras</topic><topic>Documentation</topic><topic>Fires</topic><toplevel>online_resources</toplevel><creatorcontrib>Clemencio, F. C.</creatorcontrib><creatorcontrib>Loureiro, C. F. M.</creatorcontrib><creatorcontrib>Landeck, J.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE/IET Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection><collection>RCAAP open access repository</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Clemencio, F. C.</au><au>Loureiro, C. F. M.</au><au>Landeck, J.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>An all-digital coincidence-selection and coincidence-trigger generation for a small animal RPC-PET camera</atitle><btitle>2011 IEEE Nuclear Science Symposium Conference Record</btitle><stitle>NSSMIC</stitle><date>2011-01-01</date><risdate>2011</risdate><spage>910</spage><epage>914</epage><pages>910-914</pages><issn>1082-3654</issn><eissn>2577-0829</eissn><isbn>1467301183</isbn><isbn>9781467301183</isbn><isbn>1467301205</isbn><isbn>9781467301206</isbn><eisbn>1467301205</eisbn><eisbn>1467301191</eisbn><eisbn>9781467301206</eisbn><eisbn>9781467301190</eisbn><abstract>The time resolution for gamma photon pairs of a detector based on resistive plate chamber technology is close to 300 ps FWHM. This allows a tight time window for coincidence detection, reducing the number of random coincidences observed and the overall noise of the acquired image. We implemented, inside a Xilinx Virtex-5 field programmable gate array, a fully programmable coincidence-trigger system with sub-nanosecond resolution and low latency for a small animal RPC-PET camera being built. An automatic procedure to construct a histogram of coincidences was implemented that helps characterizing the camera and allows compensating for different delays in the time channels. The time window for coincidences can then be placed at the optimal position helping rejecting coincidences from undesired sources.</abstract><pub>IEEE</pub><doi>10.1109/NSSMIC.2011.6154569</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0003-0453-1151</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1082-3654 |
ispartof | 2011 IEEE Nuclear Science Symposium Conference Record, 2011, p.910-914 |
issn | 1082-3654 2577-0829 |
language | eng |
recordid | cdi_rcaap_revistas_10400_22_12921 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Acceleration Cameras Documentation Fires |
title | An all-digital coincidence-selection and coincidence-trigger generation for a small animal RPC-PET camera |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T11%3A50%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-rcaap_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=An%20all-digital%20coincidence-selection%20and%20coincidence-trigger%20generation%20for%20a%20small%20animal%20RPC-PET%20camera&rft.btitle=2011%20IEEE%20Nuclear%20Science%20Symposium%20Conference%20Record&rft.au=Clemencio,%20F.%20C.&rft.date=2011-01-01&rft.spage=910&rft.epage=914&rft.pages=910-914&rft.issn=1082-3654&rft.eissn=2577-0829&rft.isbn=1467301183&rft.isbn_list=9781467301183&rft.isbn_list=1467301205&rft.isbn_list=9781467301206&rft_id=info:doi/10.1109/NSSMIC.2011.6154569&rft.eisbn=1467301205&rft.eisbn_list=1467301191&rft.eisbn_list=9781467301206&rft.eisbn_list=9781467301190&rft_dat=%3Crcaap_6IE%3E10400_22_12921%3C/rcaap_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i249t-a3d212469daa52edb24e6486e1d4c884428d0ebd26292f70af2f2f990d99c9f53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6154569&rfr_iscdi=true |