Loading…

Comparison of body composition methods in overweight and obese Brazilian women

The purpose of this study was to compare skinfold thickness (SKF) and bioelectrical impedance analysis (BIA) of body composition using three different equations against dual-energy X-ray absorptiometry (DXA) in overweight and obese Brazilian women. Thirty-four women (age 43.8 +/- 10.9 years; body ma...

Full description

Saved in:
Bibliographic Details
Published in:Arquivos brasileiros de endocrinologia e metabologia 2010-06, Vol.54 (4), p.398-405
Main Authors: Braulio, Valeria Bender, Furtado, Valéria Cristina Soares, Silveira, Maria das Graças, Fonseca, Maria Helena, Oliveira, José Egídio
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The purpose of this study was to compare skinfold thickness (SKF) and bioelectrical impedance analysis (BIA) of body composition using three different equations against dual-energy X-ray absorptiometry (DXA) in overweight and obese Brazilian women. Thirty-four women (age 43.8 +/- 10.9 years; body mass index [BMI] 32.1 +/- 4.3 kg/m(2)) had percentage body fat (BF%), fat mass (FM) and fat-free mass (FFM) estimated by DXA, SKF and BIA (BIA-man: manufacturer's equation; and predictive obesity-specific equations of Segal and of Gray). Regression analysis, Bland-Altman plot analysis and intra-class correlation coefficient (ICC) were used to compare methods. Absolute agreement between DXA and BIA-man was poor for all measures of body composition (BF% -6.8% +/- 3.7%, FM -3.1 +/- 3.6 kg, FFM 5.7 +/- 2.8 kg). BIA-Segal equation showed good absolute agreement with DXA for BF% (1.5% +/- 1.5%), FM (1.0 +/- 3.2 kg) and FFM (1.5 +/- 2.6 kg), albeit the limits of agreement were wide. BIA-Gray equation showed good absolute agreement with DXA for FM (2.3 +/- 4.1 kg), and smaller biases for BF% (0.05% +/- 4.4%) and FFM (0.2 +/- 2.9 kg), although wide limits of agreement. BIA-Gray and DXA showed the highest ICC among the pairs of methods. A good absolute agreement was observed between DXA and SKF for BF% (-2.3% +/- 5.8%), FM (0.09 +/- 4.7 kg), and FFM (2.4 +/- 4.4 kg), although limits of agreement were wider and ICC between DXA and SKF for BF% indicated poor degree of reproducibility. These findings show that both BIA-Segal and BIA-Gray equations are suitable for BF%, FM and FFM estimations in overweight and obese women.
ISSN:0004-2730
1677-9487
1677-9487
0004-2730
DOI:10.1590/S0004-27302010000400009