Loading…

Optimization of a new dissolution test for oxcarbazepine capsules using mixed-level factorial design

In this work, a dissolution test for oxcarbazepine capsules was developed and validated. For the screening study, a mixed-level factorial design containing factors at three and two levels (3² × 2) was used in order to select the stirring speed, the dissolution medium and the dissolution apparatus. T...

Full description

Saved in:
Bibliographic Details
Published in:Journal of the Brazilian Chemical Society 2011-07, Vol.22 (7), p.1263-1270
Main Authors: Polonini, Hudson C, Oliveira, Marcone A. L. de, Ferreira, Anderson O, Raposo, Nádia R. B, Grossi, Lívia N, Brandão, Marcos A. F
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c345t-f7918bb53a6e19a9be06223e991b8dd3f9f9b2b2cc13193cecbf2d7bfe584d263
cites
container_end_page 1270
container_issue 7
container_start_page 1263
container_title Journal of the Brazilian Chemical Society
container_volume 22
creator Polonini, Hudson C
Oliveira, Marcone A. L. de
Ferreira, Anderson O
Raposo, Nádia R. B
Grossi, Lívia N
Brandão, Marcos A. F
description In this work, a dissolution test for oxcarbazepine capsules was developed and validated. For the screening study, a mixed-level factorial design containing factors at three and two levels (3² × 2) was used in order to select the stirring speed, the dissolution medium and the dissolution apparatus. This strategy is needful for reducing the time of method development and to provide less ambiguous data. The best in vitro percentage dissolution was obtained using apparatus paddle at 80 rpm and sodium lauryl sulfate 1% m/v aqueous solution as the dissolution medium. The quantification of the mass dissolved was obtained by UV-Vis spectrophotometric analysis at 304 nm. The validation results demonstrate that the method was precise and linear over the range of 83-249 µg mL-1 of oxcarbazepine. Thus, the method is useful and adequate for oxcarbazepine capsules dissolution test, once there is no official monograph regarding it.
doi_str_mv 10.1590/S0103-50532011000700011
format article
fullrecord <record><control><sourceid>scielo_cross</sourceid><recordid>TN_cdi_scielo_journals_S0103_50532011000700011</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S0103_50532011000700011</scielo_id><sourcerecordid>S0103_50532011000700011</sourcerecordid><originalsourceid>FETCH-LOGICAL-c345t-f7918bb53a6e19a9be06223e991b8dd3f9f9b2b2cc13193cecbf2d7bfe584d263</originalsourceid><addsrcrecordid>eNp1kMtOwzAQRb0AiVL4BvwDKX7USbxEFS-pUhfAOvJjXLly4shOoPTrCS1ig1iMRpo7Z0Y6CN1QsqBCktsXQgkvBBGcEUoJIdVUlJ6h2W9wgS5z3hHCxLQ0Q3bTD771BzX42OHosMIdfGDrc45hPA4HyAN2MeG4NyppdYDed4CN6vMYIOMx-26LW78HWwR4h4CdMkNMXgVsIfttd4XOnQoZrn_6HL093L-unor15vF5dbcuDF-KoXCVpLXWgqsSqFRSAykZ4yAl1bW13EknNdPMGMqp5AaMdsxW2oGol5aVfI4Wp7vZeAix2cUxddPD5uil-eNlAqoTYFLMOYFr-uRblT4bSppvo_-SXxHca0w</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Optimization of a new dissolution test for oxcarbazepine capsules using mixed-level factorial design</title><source>SciELO Brazil</source><creator>Polonini, Hudson C ; Oliveira, Marcone A. L. de ; Ferreira, Anderson O ; Raposo, Nádia R. B ; Grossi, Lívia N ; Brandão, Marcos A. F</creator><creatorcontrib>Polonini, Hudson C ; Oliveira, Marcone A. L. de ; Ferreira, Anderson O ; Raposo, Nádia R. B ; Grossi, Lívia N ; Brandão, Marcos A. F</creatorcontrib><description>In this work, a dissolution test for oxcarbazepine capsules was developed and validated. For the screening study, a mixed-level factorial design containing factors at three and two levels (3² × 2) was used in order to select the stirring speed, the dissolution medium and the dissolution apparatus. This strategy is needful for reducing the time of method development and to provide less ambiguous data. The best in vitro percentage dissolution was obtained using apparatus paddle at 80 rpm and sodium lauryl sulfate 1% m/v aqueous solution as the dissolution medium. The quantification of the mass dissolved was obtained by UV-Vis spectrophotometric analysis at 304 nm. The validation results demonstrate that the method was precise and linear over the range of 83-249 µg mL-1 of oxcarbazepine. Thus, the method is useful and adequate for oxcarbazepine capsules dissolution test, once there is no official monograph regarding it.</description><identifier>ISSN: 0103-5053</identifier><identifier>ISSN: 1678-4790</identifier><identifier>DOI: 10.1590/S0103-50532011000700011</identifier><language>eng</language><publisher>Sociedade Brasileira de Química</publisher><subject>CHEMISTRY, MULTIDISCIPLINARY</subject><ispartof>Journal of the Brazilian Chemical Society, 2011-07, Vol.22 (7), p.1263-1270</ispartof><rights>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c345t-f7918bb53a6e19a9be06223e991b8dd3f9f9b2b2cc13193cecbf2d7bfe584d263</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,24150,27924,27925</link.rule.ids></links><search><creatorcontrib>Polonini, Hudson C</creatorcontrib><creatorcontrib>Oliveira, Marcone A. L. de</creatorcontrib><creatorcontrib>Ferreira, Anderson O</creatorcontrib><creatorcontrib>Raposo, Nádia R. B</creatorcontrib><creatorcontrib>Grossi, Lívia N</creatorcontrib><creatorcontrib>Brandão, Marcos A. F</creatorcontrib><title>Optimization of a new dissolution test for oxcarbazepine capsules using mixed-level factorial design</title><title>Journal of the Brazilian Chemical Society</title><addtitle>J. Braz. Chem. Soc</addtitle><description>In this work, a dissolution test for oxcarbazepine capsules was developed and validated. For the screening study, a mixed-level factorial design containing factors at three and two levels (3² × 2) was used in order to select the stirring speed, the dissolution medium and the dissolution apparatus. This strategy is needful for reducing the time of method development and to provide less ambiguous data. The best in vitro percentage dissolution was obtained using apparatus paddle at 80 rpm and sodium lauryl sulfate 1% m/v aqueous solution as the dissolution medium. The quantification of the mass dissolved was obtained by UV-Vis spectrophotometric analysis at 304 nm. The validation results demonstrate that the method was precise and linear over the range of 83-249 µg mL-1 of oxcarbazepine. Thus, the method is useful and adequate for oxcarbazepine capsules dissolution test, once there is no official monograph regarding it.</description><subject>CHEMISTRY, MULTIDISCIPLINARY</subject><issn>0103-5053</issn><issn>1678-4790</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNp1kMtOwzAQRb0AiVL4BvwDKX7USbxEFS-pUhfAOvJjXLly4shOoPTrCS1ig1iMRpo7Z0Y6CN1QsqBCktsXQgkvBBGcEUoJIdVUlJ6h2W9wgS5z3hHCxLQ0Q3bTD771BzX42OHosMIdfGDrc45hPA4HyAN2MeG4NyppdYDed4CN6vMYIOMx-26LW78HWwR4h4CdMkNMXgVsIfttd4XOnQoZrn_6HL093L-unor15vF5dbcuDF-KoXCVpLXWgqsSqFRSAykZ4yAl1bW13EknNdPMGMqp5AaMdsxW2oGol5aVfI4Wp7vZeAix2cUxddPD5uil-eNlAqoTYFLMOYFr-uRblT4bSppvo_-SXxHca0w</recordid><startdate>20110701</startdate><enddate>20110701</enddate><creator>Polonini, Hudson C</creator><creator>Oliveira, Marcone A. L. de</creator><creator>Ferreira, Anderson O</creator><creator>Raposo, Nádia R. B</creator><creator>Grossi, Lívia N</creator><creator>Brandão, Marcos A. F</creator><general>Sociedade Brasileira de Química</general><scope>AAYXX</scope><scope>CITATION</scope><scope>GPN</scope></search><sort><creationdate>20110701</creationdate><title>Optimization of a new dissolution test for oxcarbazepine capsules using mixed-level factorial design</title><author>Polonini, Hudson C ; Oliveira, Marcone A. L. de ; Ferreira, Anderson O ; Raposo, Nádia R. B ; Grossi, Lívia N ; Brandão, Marcos A. F</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c345t-f7918bb53a6e19a9be06223e991b8dd3f9f9b2b2cc13193cecbf2d7bfe584d263</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>CHEMISTRY, MULTIDISCIPLINARY</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Polonini, Hudson C</creatorcontrib><creatorcontrib>Oliveira, Marcone A. L. de</creatorcontrib><creatorcontrib>Ferreira, Anderson O</creatorcontrib><creatorcontrib>Raposo, Nádia R. B</creatorcontrib><creatorcontrib>Grossi, Lívia N</creatorcontrib><creatorcontrib>Brandão, Marcos A. F</creatorcontrib><collection>CrossRef</collection><collection>SciELO</collection><jtitle>Journal of the Brazilian Chemical Society</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Polonini, Hudson C</au><au>Oliveira, Marcone A. L. de</au><au>Ferreira, Anderson O</au><au>Raposo, Nádia R. B</au><au>Grossi, Lívia N</au><au>Brandão, Marcos A. F</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optimization of a new dissolution test for oxcarbazepine capsules using mixed-level factorial design</atitle><jtitle>Journal of the Brazilian Chemical Society</jtitle><addtitle>J. Braz. Chem. Soc</addtitle><date>2011-07-01</date><risdate>2011</risdate><volume>22</volume><issue>7</issue><spage>1263</spage><epage>1270</epage><pages>1263-1270</pages><issn>0103-5053</issn><issn>1678-4790</issn><abstract>In this work, a dissolution test for oxcarbazepine capsules was developed and validated. For the screening study, a mixed-level factorial design containing factors at three and two levels (3² × 2) was used in order to select the stirring speed, the dissolution medium and the dissolution apparatus. This strategy is needful for reducing the time of method development and to provide less ambiguous data. The best in vitro percentage dissolution was obtained using apparatus paddle at 80 rpm and sodium lauryl sulfate 1% m/v aqueous solution as the dissolution medium. The quantification of the mass dissolved was obtained by UV-Vis spectrophotometric analysis at 304 nm. The validation results demonstrate that the method was precise and linear over the range of 83-249 µg mL-1 of oxcarbazepine. Thus, the method is useful and adequate for oxcarbazepine capsules dissolution test, once there is no official monograph regarding it.</abstract><pub>Sociedade Brasileira de Química</pub><doi>10.1590/S0103-50532011000700011</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0103-5053
ispartof Journal of the Brazilian Chemical Society, 2011-07, Vol.22 (7), p.1263-1270
issn 0103-5053
1678-4790
language eng
recordid cdi_scielo_journals_S0103_50532011000700011
source SciELO Brazil
subjects CHEMISTRY, MULTIDISCIPLINARY
title Optimization of a new dissolution test for oxcarbazepine capsules using mixed-level factorial design
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T16%3A34%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scielo_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optimization%20of%20a%20new%20dissolution%20test%20for%20oxcarbazepine%20capsules%20using%20mixed-level%20factorial%20design&rft.jtitle=Journal%20of%20the%20Brazilian%20Chemical%20Society&rft.au=Polonini,%20Hudson%20C&rft.date=2011-07-01&rft.volume=22&rft.issue=7&rft.spage=1263&rft.epage=1270&rft.pages=1263-1270&rft.issn=0103-5053&rft_id=info:doi/10.1590/S0103-50532011000700011&rft_dat=%3Cscielo_cross%3ES0103_50532011000700011%3C/scielo_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c345t-f7918bb53a6e19a9be06223e991b8dd3f9f9b2b2cc13193cecbf2d7bfe584d263%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_scielo_id=S0103_50532011000700011&rfr_iscdi=true