Loading…

High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs

To evaluate the reliability of high-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers, 20 dogs with no structural cardiac alterations at echocardiographic examination were grouped on the basis of frequency of ventricular arrhythmias, evaluat...

Full description

Saved in:
Bibliographic Details
Published in:Ciência rural 2013-06, Vol.43 (6), p.1102-1106
Main Authors: Pereira, Evandro Zacché, Assumpção, Thais Cristine Alves, Gering, Ana Paula, Gava, Fábio Nelson, Ortiz, Edna Mireya Gómez, Camacho, Aparecido Antonio
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To evaluate the reliability of high-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers, 20 dogs with no structural cardiac alterations at echocardiographic examination were grouped on the basis of frequency of ventricular arrhythmias, evaluated by 24-hour ambulatory ECG, and undergoing a high-resolution electrocardiography. High frequency QRS duration, duration of terminal QRS complex less than 40µV (LAS40) and root mean square voltage of the terminal 40 milliseconds of the QRS complex (RMS40) were measured. Differences in high-resolution ECG variables were not observed between groups. Therefore, the results of this investigation suggest that high-resolution electrocardiography is not a useful method for the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers without detectable myocardial alterations or systolic dysfunction. Com o objetivo de avaliar a importância da eletrocardiografia de alta resolução no diagnóstico da cardiomiopatia arritmogênica do ventrículo direito do Boxer, 20 cães sem evidências de doença cardíaca estrutural à avaliação ecodopplercardiográfica foram agrupados de acordo com a frequência de arritmias ventriculares, avaliadas pela eletrocardiografia ambulatorial de 24 horas, e submetidos ao exame eletrocardiográfico de alta resolução. Duração do complexo QRS filtrado, duração dos sinais de baixa amplitude (menor que 40µV) dos últimos 40 milissegundos do complexo QRS e raiz quadrada média da voltagem ao quadrado dos últimos 40 milissegundos do complexo QRS (RMS40) foram as variáveis avaliadas. Não foram observadas diferenças significativas entre os grupos em relação às variáveis estudadas. Sendo assim, os resultados do presente estudo sugerem que a eletrocardiografia de alta resolução não é uma ferramenta útil no auxílio diagnóstico da cardiomiopatia arritmogênica do ventrículo direito dos cães da raça Boxer que não apresentam alterações miocárdicas evidentes ou disfunção sistólica.
ISSN:0103-8478
1678-4596
0103-8478
DOI:10.1590/S0103-84782013000600025