Loading…

Trace element concentration in São Francisco River water using STXRF and PIXE techniques

Trace element concentrations in water from São Francisco River using Particle Induced X-ray Emission (PIXE) and Synchroton Total Reflection X-ray Fluorescence (STXRF) techniques are measured. The main objective of this work was to characterize and to monitor the trace elements in the water of São Fr...

Full description

Saved in:
Bibliographic Details
Published in:Brazilian journal of physics 2005-09, Vol.35 (3b), p.757-760
Main Authors: Espinoza-Quiñones, F. R., Palacio, S. M., Galante, R. M., Rossi, F. L., Zenatti, D. C., Pereira, I. R. A., Welter, R. A., Rossi, N., Obregón, C. L., Abreu, J. M. T. de, Rizzutto, M. A., Added, N., Tabacniks, M. H.
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 760
container_issue 3b
container_start_page 757
container_title Brazilian journal of physics
container_volume 35
creator Espinoza-Quiñones, F. R.
Palacio, S. M.
Galante, R. M.
Rossi, F. L.
Zenatti, D. C.
Pereira, I. R. A.
Welter, R. A.
Rossi, N.
Obregón, C. L.
Abreu, J. M. T. de
Rizzutto, M. A.
Added, N.
Tabacniks, M. H.
description Trace element concentrations in water from São Francisco River using Particle Induced X-ray Emission (PIXE) and Synchroton Total Reflection X-ray Fluorescence (STXRF) techniques are measured. The main objective of this work was to characterize and to monitor the trace elements in the water of São Francisco River, as well as to provide valuable information about the levels of metallic ions pollutants. Water samples were collected monthly at five locations along the course of the river from July 2003 to April 2004. As an internal standard, 11.6 ppm of Yttrium was added to 10 ml of the water sample. The PIXE and TXRF measurements were performed at the Ion Beams and Materials Laboratory (LAMFI) and the Brazilian National Synchrotron Light Laboratory (LNLS), using a proton beam and a polychromatic X-ray beam, respectively. Si(Li) detectors were used to collect the X-ray spectra. Due to the excellent detection limits of the PIXE and STXRF analysis, up to 15 elements were quantified. The highest total content of Cr, As, Cu and Zn detected in river water are above the limits recommended by the environmental legislation.
doi_str_mv 10.1590/S0103-97332005000500009
format article
fullrecord <record><control><sourceid>scielo_cross</sourceid><recordid>TN_cdi_scielo_journals_S0103_97332005000500009</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S0103_97332005000500009</scielo_id><sourcerecordid>S0103_97332005000500009</sourcerecordid><originalsourceid>FETCH-LOGICAL-c291t-de3f1e898ed5921fcc36c9110bc6f0dad5e78d89e5370b5db6a3c228fce645ab3</originalsourceid><addsrcrecordid>eNp1kFFKAzEQhoMoWKtnMBdYnWya3c2jlFYLBaWtUJ-W7OysprSJJlvF83gUL-ZqRQTxYeYfGL4Z-Bg7FXAmlIbzOQiQic6lTAEU7Ar0Huv9LPZ_zYfsKMYVQKpgIHvsbhEMEqc1bci1HL3DLoNprXfcOj5_f_N8HIxDG9HzmX2mwF9M2_VttO6ezxfL2ZgbV_ObyXLEW8IHZ5-2FI_ZQWPWkU6-s89ux6PF8CqZXl9OhhfTBFMt2qQm2QgqdEG10qloEGWGWgioMGugNrWivKgLTUrmUKm6yozENC0apGygTCX77Gx3N6KltS9Xfhtc97D8ElP-EdMB-Q7A4GMM1JSPwW5MeC0FlJ9K_yU_AG1TaCM</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Trace element concentration in São Francisco River water using STXRF and PIXE techniques</title><source>SciELO</source><source>EZB Electronic Journals Library</source><creator>Espinoza-Quiñones, F. R. ; Palacio, S. M. ; Galante, R. M. ; Rossi, F. L. ; Zenatti, D. C. ; Pereira, I. R. A. ; Welter, R. A. ; Rossi, N. ; Obregón, C. L. ; Abreu, J. M. T. de ; Rizzutto, M. A. ; Added, N. ; Tabacniks, M. H.</creator><creatorcontrib>Espinoza-Quiñones, F. R. ; Palacio, S. M. ; Galante, R. M. ; Rossi, F. L. ; Zenatti, D. C. ; Pereira, I. R. A. ; Welter, R. A. ; Rossi, N. ; Obregón, C. L. ; Abreu, J. M. T. de ; Rizzutto, M. A. ; Added, N. ; Tabacniks, M. H.</creatorcontrib><description>Trace element concentrations in water from São Francisco River using Particle Induced X-ray Emission (PIXE) and Synchroton Total Reflection X-ray Fluorescence (STXRF) techniques are measured. The main objective of this work was to characterize and to monitor the trace elements in the water of São Francisco River, as well as to provide valuable information about the levels of metallic ions pollutants. Water samples were collected monthly at five locations along the course of the river from July 2003 to April 2004. As an internal standard, 11.6 ppm of Yttrium was added to 10 ml of the water sample. The PIXE and TXRF measurements were performed at the Ion Beams and Materials Laboratory (LAMFI) and the Brazilian National Synchrotron Light Laboratory (LNLS), using a proton beam and a polychromatic X-ray beam, respectively. Si(Li) detectors were used to collect the X-ray spectra. Due to the excellent detection limits of the PIXE and STXRF analysis, up to 15 elements were quantified. The highest total content of Cr, As, Cu and Zn detected in river water are above the limits recommended by the environmental legislation.</description><identifier>ISSN: 0103-9733</identifier><identifier>ISSN: 1678-4448</identifier><identifier>EISSN: 0103-9733</identifier><identifier>DOI: 10.1590/S0103-97332005000500009</identifier><language>eng</language><publisher>Sociedade Brasileira de Física</publisher><subject>PHYSICS, MULTIDISCIPLINARY</subject><ispartof>Brazilian journal of physics, 2005-09, Vol.35 (3b), p.757-760</ispartof><rights>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,24150,27924,27925</link.rule.ids></links><search><creatorcontrib>Espinoza-Quiñones, F. R.</creatorcontrib><creatorcontrib>Palacio, S. M.</creatorcontrib><creatorcontrib>Galante, R. M.</creatorcontrib><creatorcontrib>Rossi, F. L.</creatorcontrib><creatorcontrib>Zenatti, D. C.</creatorcontrib><creatorcontrib>Pereira, I. R. A.</creatorcontrib><creatorcontrib>Welter, R. A.</creatorcontrib><creatorcontrib>Rossi, N.</creatorcontrib><creatorcontrib>Obregón, C. L.</creatorcontrib><creatorcontrib>Abreu, J. M. T. de</creatorcontrib><creatorcontrib>Rizzutto, M. A.</creatorcontrib><creatorcontrib>Added, N.</creatorcontrib><creatorcontrib>Tabacniks, M. H.</creatorcontrib><title>Trace element concentration in São Francisco River water using STXRF and PIXE techniques</title><title>Brazilian journal of physics</title><addtitle>Braz. J. Phys</addtitle><description>Trace element concentrations in water from São Francisco River using Particle Induced X-ray Emission (PIXE) and Synchroton Total Reflection X-ray Fluorescence (STXRF) techniques are measured. The main objective of this work was to characterize and to monitor the trace elements in the water of São Francisco River, as well as to provide valuable information about the levels of metallic ions pollutants. Water samples were collected monthly at five locations along the course of the river from July 2003 to April 2004. As an internal standard, 11.6 ppm of Yttrium was added to 10 ml of the water sample. The PIXE and TXRF measurements were performed at the Ion Beams and Materials Laboratory (LAMFI) and the Brazilian National Synchrotron Light Laboratory (LNLS), using a proton beam and a polychromatic X-ray beam, respectively. Si(Li) detectors were used to collect the X-ray spectra. Due to the excellent detection limits of the PIXE and STXRF analysis, up to 15 elements were quantified. The highest total content of Cr, As, Cu and Zn detected in river water are above the limits recommended by the environmental legislation.</description><subject>PHYSICS, MULTIDISCIPLINARY</subject><issn>0103-9733</issn><issn>1678-4448</issn><issn>0103-9733</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNp1kFFKAzEQhoMoWKtnMBdYnWya3c2jlFYLBaWtUJ-W7OysprSJJlvF83gUL-ZqRQTxYeYfGL4Z-Bg7FXAmlIbzOQiQic6lTAEU7Ar0Huv9LPZ_zYfsKMYVQKpgIHvsbhEMEqc1bci1HL3DLoNprXfcOj5_f_N8HIxDG9HzmX2mwF9M2_VttO6ezxfL2ZgbV_ObyXLEW8IHZ5-2FI_ZQWPWkU6-s89ux6PF8CqZXl9OhhfTBFMt2qQm2QgqdEG10qloEGWGWgioMGugNrWivKgLTUrmUKm6yozENC0apGygTCX77Gx3N6KltS9Xfhtc97D8ElP-EdMB-Q7A4GMM1JSPwW5MeC0FlJ9K_yU_AG1TaCM</recordid><startdate>20050901</startdate><enddate>20050901</enddate><creator>Espinoza-Quiñones, F. R.</creator><creator>Palacio, S. M.</creator><creator>Galante, R. M.</creator><creator>Rossi, F. L.</creator><creator>Zenatti, D. C.</creator><creator>Pereira, I. R. A.</creator><creator>Welter, R. A.</creator><creator>Rossi, N.</creator><creator>Obregón, C. L.</creator><creator>Abreu, J. M. T. de</creator><creator>Rizzutto, M. A.</creator><creator>Added, N.</creator><creator>Tabacniks, M. H.</creator><general>Sociedade Brasileira de Física</general><scope>AAYXX</scope><scope>CITATION</scope><scope>GPN</scope></search><sort><creationdate>20050901</creationdate><title>Trace element concentration in São Francisco River water using STXRF and PIXE techniques</title><author>Espinoza-Quiñones, F. R. ; Palacio, S. M. ; Galante, R. M. ; Rossi, F. L. ; Zenatti, D. C. ; Pereira, I. R. A. ; Welter, R. A. ; Rossi, N. ; Obregón, C. L. ; Abreu, J. M. T. de ; Rizzutto, M. A. ; Added, N. ; Tabacniks, M. H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c291t-de3f1e898ed5921fcc36c9110bc6f0dad5e78d89e5370b5db6a3c228fce645ab3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>PHYSICS, MULTIDISCIPLINARY</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Espinoza-Quiñones, F. R.</creatorcontrib><creatorcontrib>Palacio, S. M.</creatorcontrib><creatorcontrib>Galante, R. M.</creatorcontrib><creatorcontrib>Rossi, F. L.</creatorcontrib><creatorcontrib>Zenatti, D. C.</creatorcontrib><creatorcontrib>Pereira, I. R. A.</creatorcontrib><creatorcontrib>Welter, R. A.</creatorcontrib><creatorcontrib>Rossi, N.</creatorcontrib><creatorcontrib>Obregón, C. L.</creatorcontrib><creatorcontrib>Abreu, J. M. T. de</creatorcontrib><creatorcontrib>Rizzutto, M. A.</creatorcontrib><creatorcontrib>Added, N.</creatorcontrib><creatorcontrib>Tabacniks, M. H.</creatorcontrib><collection>CrossRef</collection><collection>SciELO</collection><jtitle>Brazilian journal of physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Espinoza-Quiñones, F. R.</au><au>Palacio, S. M.</au><au>Galante, R. M.</au><au>Rossi, F. L.</au><au>Zenatti, D. C.</au><au>Pereira, I. R. A.</au><au>Welter, R. A.</au><au>Rossi, N.</au><au>Obregón, C. L.</au><au>Abreu, J. M. T. de</au><au>Rizzutto, M. A.</au><au>Added, N.</au><au>Tabacniks, M. H.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Trace element concentration in São Francisco River water using STXRF and PIXE techniques</atitle><jtitle>Brazilian journal of physics</jtitle><addtitle>Braz. J. Phys</addtitle><date>2005-09-01</date><risdate>2005</risdate><volume>35</volume><issue>3b</issue><spage>757</spage><epage>760</epage><pages>757-760</pages><issn>0103-9733</issn><issn>1678-4448</issn><eissn>0103-9733</eissn><abstract>Trace element concentrations in water from São Francisco River using Particle Induced X-ray Emission (PIXE) and Synchroton Total Reflection X-ray Fluorescence (STXRF) techniques are measured. The main objective of this work was to characterize and to monitor the trace elements in the water of São Francisco River, as well as to provide valuable information about the levels of metallic ions pollutants. Water samples were collected monthly at five locations along the course of the river from July 2003 to April 2004. As an internal standard, 11.6 ppm of Yttrium was added to 10 ml of the water sample. The PIXE and TXRF measurements were performed at the Ion Beams and Materials Laboratory (LAMFI) and the Brazilian National Synchrotron Light Laboratory (LNLS), using a proton beam and a polychromatic X-ray beam, respectively. Si(Li) detectors were used to collect the X-ray spectra. Due to the excellent detection limits of the PIXE and STXRF analysis, up to 15 elements were quantified. The highest total content of Cr, As, Cu and Zn detected in river water are above the limits recommended by the environmental legislation.</abstract><pub>Sociedade Brasileira de Física</pub><doi>10.1590/S0103-97332005000500009</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0103-9733
ispartof Brazilian journal of physics, 2005-09, Vol.35 (3b), p.757-760
issn 0103-9733
1678-4448
0103-9733
language eng
recordid cdi_scielo_journals_S0103_97332005000500009
source SciELO; EZB Electronic Journals Library
subjects PHYSICS, MULTIDISCIPLINARY
title Trace element concentration in São Francisco River water using STXRF and PIXE techniques
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T11%3A03%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scielo_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Trace%20element%20concentration%20in%20S%C3%A3o%20Francisco%20River%20water%20using%20STXRF%20and%20PIXE%20techniques&rft.jtitle=Brazilian%20journal%20of%20physics&rft.au=Espinoza-Qui%C3%B1ones,%20F.%20R.&rft.date=2005-09-01&rft.volume=35&rft.issue=3b&rft.spage=757&rft.epage=760&rft.pages=757-760&rft.issn=0103-9733&rft.eissn=0103-9733&rft_id=info:doi/10.1590/S0103-97332005000500009&rft_dat=%3Cscielo_cross%3ES0103_97332005000500009%3C/scielo_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c291t-de3f1e898ed5921fcc36c9110bc6f0dad5e78d89e5370b5db6a3c228fce645ab3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_scielo_id=S0103_97332005000500009&rfr_iscdi=true