Evaluation of tensile strength after insertions andremovals of abutments on frictional Morse taper implants
This study aimed to evaluate possible changes in final retention after nine sequences of insertion and removal (SIR) of a frictional Morse taper implant/abutment system, evaluating the force required for dissociating this set between sequences, and verifying possible deformations in the implant head...
Saved in:
Published in: | International journal of odontostomatology 2021-06, Vol.15 (2), p.356-362 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c1906-a7bced9b5fff264f73e6755dee230e6f69faf2e06b41e03a9f4d84fa89a861a63 |
---|---|
cites | |
container_end_page | 362 |
container_issue | 2 |
container_start_page | 356 |
container_title | International journal of odontostomatology |
container_volume | 15 |
creator | da-Silva, Jader Moreira Sobral, Brenda Santos Cabral, Carolina Takis Souza, Cíntia de Melo Silva Fonseca, Ricardo Roberto de Souza Ramacciato, Juliana Cama |
description | This study aimed to evaluate possible changes in final retention after nine sequences of insertion and removal (SIR) of a frictional Morse taper implant/abutment system, evaluating the force required for dissociating this set between sequences, and verifying possible deformations in the implant heads. Ten implants, 13 mm long and 3.3 mm in diameter, were coupled to a universal mechanical testing machine. Ten anti-rotational abutments, 13 mm long and 3.5 mm in diameter, were connected to the implants parallel to the long axis, using an instrument called beat-connection, and subjected to tensile tests and SEM analysis. The results were analyzed using the Kruskal-Wallis test with Dunn’s post-test, and the significance level was set at 5 %. There was no statistically significant difference in final retention among the nine SIRs evaluated. The force needed to uncouple the abutment from the implant increased as SIRs were performed on all ten implants, and an increase of 29.03 % was observed in the ninth SIR compared to the first SIR. After SEM analysis, no significant deformations, fractures, or cracks were observed in the implant heads. |
doi_str_mv | 10.4067/S0718-381X2021000200356 |
format | article |
fullrecord | <record><control><sourceid>scielo_cross</sourceid><recordid>TN_cdi_scielo_journals_S0718_381X2021000200356</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S0718_381X2021000200356</scielo_id><sourcerecordid>S0718_381X2021000200356</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1906-a7bced9b5fff264f73e6755dee230e6f69faf2e06b41e03a9f4d84fa89a861a63</originalsourceid><addsrcrecordid>eNp1kNtKxDAQhoMouKz7DOYFuk56SNtLWdYDrHihgndl2k402iZLkhV8e9NdEUG8mhnm-4bhZ-xcwDIHWV48QCmqJKvEcwqpAIAUICvkEZv9LI5_9ads4b1uAapU5pGesff1Bw47DNoabhUPZLweiPvgyLyEV44qkOPaeHIT4zma3tFoo-UnAdtdGMmEOBiunO4mCgd-Z50nHnA72eN2wIicsRMVNVp81zl7ulo_rm6Szf317epyk3SiBplg2XbU122hlIpvqjIjWRZFT5RmQFLJWqFKCWSbC4IMa5X3Va6wqrGSAmU2Z8vDXd9pGmzzZncu_uSbfVrNn7SiUB6EzlnvHalm6_SI7rMR0Ew5_2t-AdFhcdk</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Evaluation of tensile strength after insertions andremovals of abutments on frictional Morse taper implants</title><source>SciELO Chile</source><creator>da-Silva, Jader Moreira ; Sobral, Brenda Santos ; Cabral, Carolina Takis ; Souza, Cíntia de Melo Silva ; Fonseca, Ricardo Roberto de Souza ; Ramacciato, Juliana Cama</creator><creatorcontrib>da-Silva, Jader Moreira ; Sobral, Brenda Santos ; Cabral, Carolina Takis ; Souza, Cíntia de Melo Silva ; Fonseca, Ricardo Roberto de Souza ; Ramacciato, Juliana Cama</creatorcontrib><description>This study aimed to evaluate possible changes in final retention after nine sequences of insertion and removal (SIR) of a frictional Morse taper implant/abutment system, evaluating the force required for dissociating this set between sequences, and verifying possible deformations in the implant heads. Ten implants, 13 mm long and 3.3 mm in diameter, were coupled to a universal mechanical testing machine. Ten anti-rotational abutments, 13 mm long and 3.5 mm in diameter, were connected to the implants parallel to the long axis, using an instrument called beat-connection, and subjected to tensile tests and SEM analysis. The results were analyzed using the Kruskal-Wallis test with Dunn’s post-test, and the significance level was set at 5 %. There was no statistically significant difference in final retention among the nine SIRs evaluated. The force needed to uncouple the abutment from the implant increased as SIRs were performed on all ten implants, and an increase of 29.03 % was observed in the ninth SIR compared to the first SIR. After SEM analysis, no significant deformations, fractures, or cracks were observed in the implant heads.</description><identifier>ISSN: 0718-381X</identifier><identifier>EISSN: 0718-381X</identifier><identifier>DOI: 10.4067/S0718-381X2021000200356</identifier><language>eng</language><publisher>Universidad de La Frontera. Facultad de Medicina</publisher><subject>DENTISTRY, ORAL SURGERY & MEDICINE</subject><ispartof>International journal of odontostomatology, 2021-06, Vol.15 (2), p.356-362</ispartof><rights>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c1906-a7bced9b5fff264f73e6755dee230e6f69faf2e06b41e03a9f4d84fa89a861a63</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,24151,27924,27925</link.rule.ids></links><search><creatorcontrib>da-Silva, Jader Moreira</creatorcontrib><creatorcontrib>Sobral, Brenda Santos</creatorcontrib><creatorcontrib>Cabral, Carolina Takis</creatorcontrib><creatorcontrib>Souza, Cíntia de Melo Silva</creatorcontrib><creatorcontrib>Fonseca, Ricardo Roberto de Souza</creatorcontrib><creatorcontrib>Ramacciato, Juliana Cama</creatorcontrib><title>Evaluation of tensile strength after insertions andremovals of abutments on frictional Morse taper implants</title><title>International journal of odontostomatology</title><addtitle>Int. J. Odontostomat</addtitle><description>This study aimed to evaluate possible changes in final retention after nine sequences of insertion and removal (SIR) of a frictional Morse taper implant/abutment system, evaluating the force required for dissociating this set between sequences, and verifying possible deformations in the implant heads. Ten implants, 13 mm long and 3.3 mm in diameter, were coupled to a universal mechanical testing machine. Ten anti-rotational abutments, 13 mm long and 3.5 mm in diameter, were connected to the implants parallel to the long axis, using an instrument called beat-connection, and subjected to tensile tests and SEM analysis. The results were analyzed using the Kruskal-Wallis test with Dunn’s post-test, and the significance level was set at 5 %. There was no statistically significant difference in final retention among the nine SIRs evaluated. The force needed to uncouple the abutment from the implant increased as SIRs were performed on all ten implants, and an increase of 29.03 % was observed in the ninth SIR compared to the first SIR. After SEM analysis, no significant deformations, fractures, or cracks were observed in the implant heads.</description><subject>DENTISTRY, ORAL SURGERY & MEDICINE</subject><issn>0718-381X</issn><issn>0718-381X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp1kNtKxDAQhoMouKz7DOYFuk56SNtLWdYDrHihgndl2k402iZLkhV8e9NdEUG8mhnm-4bhZ-xcwDIHWV48QCmqJKvEcwqpAIAUICvkEZv9LI5_9ads4b1uAapU5pGesff1Bw47DNoabhUPZLweiPvgyLyEV44qkOPaeHIT4zma3tFoo-UnAdtdGMmEOBiunO4mCgd-Z50nHnA72eN2wIicsRMVNVp81zl7ulo_rm6Szf317epyk3SiBplg2XbU122hlIpvqjIjWRZFT5RmQFLJWqFKCWSbC4IMa5X3Va6wqrGSAmU2Z8vDXd9pGmzzZncu_uSbfVrNn7SiUB6EzlnvHalm6_SI7rMR0Ew5_2t-AdFhcdk</recordid><startdate>202106</startdate><enddate>202106</enddate><creator>da-Silva, Jader Moreira</creator><creator>Sobral, Brenda Santos</creator><creator>Cabral, Carolina Takis</creator><creator>Souza, Cíntia de Melo Silva</creator><creator>Fonseca, Ricardo Roberto de Souza</creator><creator>Ramacciato, Juliana Cama</creator><general>Universidad de La Frontera. Facultad de Medicina</general><scope>AAYXX</scope><scope>CITATION</scope><scope>GPN</scope></search><sort><creationdate>202106</creationdate><title>Evaluation of tensile strength after insertions andremovals of abutments on frictional Morse taper implants</title><author>da-Silva, Jader Moreira ; Sobral, Brenda Santos ; Cabral, Carolina Takis ; Souza, Cíntia de Melo Silva ; Fonseca, Ricardo Roberto de Souza ; Ramacciato, Juliana Cama</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1906-a7bced9b5fff264f73e6755dee230e6f69faf2e06b41e03a9f4d84fa89a861a63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>DENTISTRY, ORAL SURGERY & MEDICINE</topic><toplevel>online_resources</toplevel><creatorcontrib>da-Silva, Jader Moreira</creatorcontrib><creatorcontrib>Sobral, Brenda Santos</creatorcontrib><creatorcontrib>Cabral, Carolina Takis</creatorcontrib><creatorcontrib>Souza, Cíntia de Melo Silva</creatorcontrib><creatorcontrib>Fonseca, Ricardo Roberto de Souza</creatorcontrib><creatorcontrib>Ramacciato, Juliana Cama</creatorcontrib><collection>CrossRef</collection><collection>SciELO</collection><jtitle>International journal of odontostomatology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>da-Silva, Jader Moreira</au><au>Sobral, Brenda Santos</au><au>Cabral, Carolina Takis</au><au>Souza, Cíntia de Melo Silva</au><au>Fonseca, Ricardo Roberto de Souza</au><au>Ramacciato, Juliana Cama</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of tensile strength after insertions andremovals of abutments on frictional Morse taper implants</atitle><jtitle>International journal of odontostomatology</jtitle><addtitle>Int. J. Odontostomat</addtitle><date>2021-06</date><risdate>2021</risdate><volume>15</volume><issue>2</issue><spage>356</spage><epage>362</epage><pages>356-362</pages><issn>0718-381X</issn><eissn>0718-381X</eissn><abstract>This study aimed to evaluate possible changes in final retention after nine sequences of insertion and removal (SIR) of a frictional Morse taper implant/abutment system, evaluating the force required for dissociating this set between sequences, and verifying possible deformations in the implant heads. Ten implants, 13 mm long and 3.3 mm in diameter, were coupled to a universal mechanical testing machine. Ten anti-rotational abutments, 13 mm long and 3.5 mm in diameter, were connected to the implants parallel to the long axis, using an instrument called beat-connection, and subjected to tensile tests and SEM analysis. The results were analyzed using the Kruskal-Wallis test with Dunn’s post-test, and the significance level was set at 5 %. There was no statistically significant difference in final retention among the nine SIRs evaluated. The force needed to uncouple the abutment from the implant increased as SIRs were performed on all ten implants, and an increase of 29.03 % was observed in the ninth SIR compared to the first SIR. After SEM analysis, no significant deformations, fractures, or cracks were observed in the implant heads.</abstract><pub>Universidad de La Frontera. Facultad de Medicina</pub><doi>10.4067/S0718-381X2021000200356</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0718-381X |
ispartof | International journal of odontostomatology, 2021-06, Vol.15 (2), p.356-362 |
issn | 0718-381X 0718-381X |
language | eng |
recordid | cdi_scielo_journals_S0718_381X2021000200356 |
source | SciELO Chile |
subjects | DENTISTRY, ORAL SURGERY & MEDICINE |
title | Evaluation of tensile strength after insertions andremovals of abutments on frictional Morse taper implants |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T09%3A22%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scielo_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20tensile%20strength%20after%20insertions%20andremovals%20of%20abutments%20on%20frictional%20Morse%20taper%20implants&rft.jtitle=International%20journal%20of%20odontostomatology&rft.au=da-Silva,%20Jader%20Moreira&rft.date=2021-06&rft.volume=15&rft.issue=2&rft.spage=356&rft.epage=362&rft.pages=356-362&rft.issn=0718-381X&rft.eissn=0718-381X&rft_id=info:doi/10.4067/S0718-381X2021000200356&rft_dat=%3Cscielo_cross%3ES0718_381X2021000200356%3C/scielo_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c1906-a7bced9b5fff264f73e6755dee230e6f69faf2e06b41e03a9f4d84fa89a861a63%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_scielo_id=S0718_381X2021000200356&rfr_iscdi=true |