Loading…
Ultrasound techniques for the detection of developmental dysplasia of the hip: a systematic review and meta-analysis
ABSTRACT BACKGROUND: Developmental dysplasia of the hip (DDH) encompasses a broad spectrum of hip pathologies, including femoral or acetabular dysplasia, hip instability, or both. According to the medical literature, ultrasonography is the most reliable diagnostic method for DDH. Several techniques...
Saved in:
Published in: | São Paulo medical journal 2023-04, Vol.141 (2), p.154-167 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | Portuguese |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 167 |
container_issue | 2 |
container_start_page | 154 |
container_title | São Paulo medical journal |
container_volume | 141 |
creator | Duarte, Marcio Luís Motta, Giovanna Galvão Braga Rodrigues, Natasha Vogel Majewski Chiovatto, Alessandra Rodrigues Silva Chiovatto, Eduardo Davino Iared, Wagner |
description | ABSTRACT BACKGROUND: Developmental dysplasia of the hip (DDH) encompasses a broad spectrum of hip pathologies, including femoral or acetabular dysplasia, hip instability, or both. According to the medical literature, ultrasonography is the most reliable diagnostic method for DDH. Several techniques for the assessment of hips in newborns and infants, using ultrasonography, have been described. OBJECTIVE: To compare the accuracy of the Graf technique and other diagnostic techniques for DDH. DESIGN AND SETTING: A systematic review of studies that analyzed ultrasound techniques for the diagnosis of DDH within an evidence-based health program of a federal university in São Paulo (SP), Brazil. METHODS: A systematic search of relevant literature was conducted in the PubMed, EMBASE, Cochrane Library, CINAHL, and LILACS databases for articles published up to May 5, 2020, relating to studies evaluating the diagnostic accuracy of different ultrasound techniques for diagnosing DDH. The QUADAS 2 tool was used for methodological quality evaluation. RESULTS: All hips were analyzed using the Graf method as a reference standard. The Morin technique had the highest rate of sensitivity, at 81.12–89.47%. The Suzuki and Stress tests showed 100% specificity. The Harcke technique showed a sensibility of 18.21% and specificity of 99.32%. CONCLUSION: All the techniques demonstrated at least one rate (sensibility and specificity) lower than 90.00% when compared to the Graf method. The Morin technique, as evaluated in this systematic review, is recommended after the Graf method because it has the highest sensitivity, especially with the three-pattern classification of 89.47%. REGISTRATION NUMBER: Identifier: CRD42020189686 at the International Prospective Register of Systematic Reviews (identifier: CRD42020189686). |
doi_str_mv | 10.1590/1516-3180.2021.0852.13062022 |
format | article |
fullrecord | <record><control><sourceid>scielo</sourceid><recordid>TN_cdi_scielo_journals_S1516_31802023000200154</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S1516_31802023000200154</scielo_id><sourcerecordid>S1516_31802023000200154</sourcerecordid><originalsourceid>FETCH-scielo_journals_S1516_318020230002001543</originalsourceid><addsrcrecordid>eNqVj8tOxDAMRbMAieHxD16wbXDSadVhi0DsgXVlta6aUZqUOh3UvyeV-AFW1vW9fhylHg1qU53wyVSmLkrToLZojcamstqUWGdlr9QhG3VxOtZ4o25Fzoi2qY09qPTl00IS19BD4m4M7ntlgSEukEaGnnMzuRggDllc2Md54pDIQ7_J7Ekc7daeHd38DASySeKJkutg4YvjH6C8e-JEBQXymzi5V9cDeeGHv3qn9Nvr58t7IZ3LF9pzXJcclfZjp2p3qoxRYv4a0VTH8t8Dv1q2V0o</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Ultrasound techniques for the detection of developmental dysplasia of the hip: a systematic review and meta-analysis</title><source>SciELO Brazil</source><creator>Duarte, Marcio Luís ; Motta, Giovanna Galvão Braga ; Rodrigues, Natasha Vogel Majewski ; Chiovatto, Alessandra Rodrigues Silva ; Chiovatto, Eduardo Davino ; Iared, Wagner</creator><creatorcontrib>Duarte, Marcio Luís ; Motta, Giovanna Galvão Braga ; Rodrigues, Natasha Vogel Majewski ; Chiovatto, Alessandra Rodrigues Silva ; Chiovatto, Eduardo Davino ; Iared, Wagner</creatorcontrib><description>ABSTRACT BACKGROUND: Developmental dysplasia of the hip (DDH) encompasses a broad spectrum of hip pathologies, including femoral or acetabular dysplasia, hip instability, or both. According to the medical literature, ultrasonography is the most reliable diagnostic method for DDH. Several techniques for the assessment of hips in newborns and infants, using ultrasonography, have been described. OBJECTIVE: To compare the accuracy of the Graf technique and other diagnostic techniques for DDH. DESIGN AND SETTING: A systematic review of studies that analyzed ultrasound techniques for the diagnosis of DDH within an evidence-based health program of a federal university in São Paulo (SP), Brazil. METHODS: A systematic search of relevant literature was conducted in the PubMed, EMBASE, Cochrane Library, CINAHL, and LILACS databases for articles published up to May 5, 2020, relating to studies evaluating the diagnostic accuracy of different ultrasound techniques for diagnosing DDH. The QUADAS 2 tool was used for methodological quality evaluation. RESULTS: All hips were analyzed using the Graf method as a reference standard. The Morin technique had the highest rate of sensitivity, at 81.12–89.47%. The Suzuki and Stress tests showed 100% specificity. The Harcke technique showed a sensibility of 18.21% and specificity of 99.32%. CONCLUSION: All the techniques demonstrated at least one rate (sensibility and specificity) lower than 90.00% when compared to the Graf method. The Morin technique, as evaluated in this systematic review, is recommended after the Graf method because it has the highest sensitivity, especially with the three-pattern classification of 89.47%. REGISTRATION NUMBER: Identifier: CRD42020189686 at the International Prospective Register of Systematic Reviews (identifier: CRD42020189686).</description><identifier>ISSN: 1806-9460</identifier><identifier>DOI: 10.1590/1516-3180.2021.0852.13062022</identifier><language>por</language><publisher>Associação Paulista de Medicina - APM</publisher><subject>MEDICINE, GENERAL & INTERNAL</subject><ispartof>São Paulo medical journal, 2023-04, Vol.141 (2), p.154-167</ispartof><rights>This work is licensed under a Creative Commons Attribution 4.0 International License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,24150,27924,27925</link.rule.ids></links><search><creatorcontrib>Duarte, Marcio Luís</creatorcontrib><creatorcontrib>Motta, Giovanna Galvão Braga</creatorcontrib><creatorcontrib>Rodrigues, Natasha Vogel Majewski</creatorcontrib><creatorcontrib>Chiovatto, Alessandra Rodrigues Silva</creatorcontrib><creatorcontrib>Chiovatto, Eduardo Davino</creatorcontrib><creatorcontrib>Iared, Wagner</creatorcontrib><title>Ultrasound techniques for the detection of developmental dysplasia of the hip: a systematic review and meta-analysis</title><title>São Paulo medical journal</title><addtitle>Sao Paulo Med. J</addtitle><description>ABSTRACT BACKGROUND: Developmental dysplasia of the hip (DDH) encompasses a broad spectrum of hip pathologies, including femoral or acetabular dysplasia, hip instability, or both. According to the medical literature, ultrasonography is the most reliable diagnostic method for DDH. Several techniques for the assessment of hips in newborns and infants, using ultrasonography, have been described. OBJECTIVE: To compare the accuracy of the Graf technique and other diagnostic techniques for DDH. DESIGN AND SETTING: A systematic review of studies that analyzed ultrasound techniques for the diagnosis of DDH within an evidence-based health program of a federal university in São Paulo (SP), Brazil. METHODS: A systematic search of relevant literature was conducted in the PubMed, EMBASE, Cochrane Library, CINAHL, and LILACS databases for articles published up to May 5, 2020, relating to studies evaluating the diagnostic accuracy of different ultrasound techniques for diagnosing DDH. The QUADAS 2 tool was used for methodological quality evaluation. RESULTS: All hips were analyzed using the Graf method as a reference standard. The Morin technique had the highest rate of sensitivity, at 81.12–89.47%. The Suzuki and Stress tests showed 100% specificity. The Harcke technique showed a sensibility of 18.21% and specificity of 99.32%. CONCLUSION: All the techniques demonstrated at least one rate (sensibility and specificity) lower than 90.00% when compared to the Graf method. The Morin technique, as evaluated in this systematic review, is recommended after the Graf method because it has the highest sensitivity, especially with the three-pattern classification of 89.47%. REGISTRATION NUMBER: Identifier: CRD42020189686 at the International Prospective Register of Systematic Reviews (identifier: CRD42020189686).</description><subject>MEDICINE, GENERAL & INTERNAL</subject><issn>1806-9460</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNqVj8tOxDAMRbMAieHxD16wbXDSadVhi0DsgXVlta6aUZqUOh3UvyeV-AFW1vW9fhylHg1qU53wyVSmLkrToLZojcamstqUWGdlr9QhG3VxOtZ4o25Fzoi2qY09qPTl00IS19BD4m4M7ntlgSEukEaGnnMzuRggDllc2Md54pDIQ7_J7Ekc7daeHd38DASySeKJkutg4YvjH6C8e-JEBQXymzi5V9cDeeGHv3qn9Nvr58t7IZ3LF9pzXJcclfZjp2p3qoxRYv4a0VTH8t8Dv1q2V0o</recordid><startdate>20230401</startdate><enddate>20230401</enddate><creator>Duarte, Marcio Luís</creator><creator>Motta, Giovanna Galvão Braga</creator><creator>Rodrigues, Natasha Vogel Majewski</creator><creator>Chiovatto, Alessandra Rodrigues Silva</creator><creator>Chiovatto, Eduardo Davino</creator><creator>Iared, Wagner</creator><general>Associação Paulista de Medicina - APM</general><scope>GPN</scope></search><sort><creationdate>20230401</creationdate><title>Ultrasound techniques for the detection of developmental dysplasia of the hip: a systematic review and meta-analysis</title><author>Duarte, Marcio Luís ; Motta, Giovanna Galvão Braga ; Rodrigues, Natasha Vogel Majewski ; Chiovatto, Alessandra Rodrigues Silva ; Chiovatto, Eduardo Davino ; Iared, Wagner</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-scielo_journals_S1516_318020230002001543</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>por</language><creationdate>2023</creationdate><topic>MEDICINE, GENERAL & INTERNAL</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Duarte, Marcio Luís</creatorcontrib><creatorcontrib>Motta, Giovanna Galvão Braga</creatorcontrib><creatorcontrib>Rodrigues, Natasha Vogel Majewski</creatorcontrib><creatorcontrib>Chiovatto, Alessandra Rodrigues Silva</creatorcontrib><creatorcontrib>Chiovatto, Eduardo Davino</creatorcontrib><creatorcontrib>Iared, Wagner</creatorcontrib><collection>SciELO</collection><jtitle>São Paulo medical journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Duarte, Marcio Luís</au><au>Motta, Giovanna Galvão Braga</au><au>Rodrigues, Natasha Vogel Majewski</au><au>Chiovatto, Alessandra Rodrigues Silva</au><au>Chiovatto, Eduardo Davino</au><au>Iared, Wagner</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Ultrasound techniques for the detection of developmental dysplasia of the hip: a systematic review and meta-analysis</atitle><jtitle>São Paulo medical journal</jtitle><addtitle>Sao Paulo Med. J</addtitle><date>2023-04-01</date><risdate>2023</risdate><volume>141</volume><issue>2</issue><spage>154</spage><epage>167</epage><pages>154-167</pages><issn>1806-9460</issn><abstract>ABSTRACT BACKGROUND: Developmental dysplasia of the hip (DDH) encompasses a broad spectrum of hip pathologies, including femoral or acetabular dysplasia, hip instability, or both. According to the medical literature, ultrasonography is the most reliable diagnostic method for DDH. Several techniques for the assessment of hips in newborns and infants, using ultrasonography, have been described. OBJECTIVE: To compare the accuracy of the Graf technique and other diagnostic techniques for DDH. DESIGN AND SETTING: A systematic review of studies that analyzed ultrasound techniques for the diagnosis of DDH within an evidence-based health program of a federal university in São Paulo (SP), Brazil. METHODS: A systematic search of relevant literature was conducted in the PubMed, EMBASE, Cochrane Library, CINAHL, and LILACS databases for articles published up to May 5, 2020, relating to studies evaluating the diagnostic accuracy of different ultrasound techniques for diagnosing DDH. The QUADAS 2 tool was used for methodological quality evaluation. RESULTS: All hips were analyzed using the Graf method as a reference standard. The Morin technique had the highest rate of sensitivity, at 81.12–89.47%. The Suzuki and Stress tests showed 100% specificity. The Harcke technique showed a sensibility of 18.21% and specificity of 99.32%. CONCLUSION: All the techniques demonstrated at least one rate (sensibility and specificity) lower than 90.00% when compared to the Graf method. The Morin technique, as evaluated in this systematic review, is recommended after the Graf method because it has the highest sensitivity, especially with the three-pattern classification of 89.47%. REGISTRATION NUMBER: Identifier: CRD42020189686 at the International Prospective Register of Systematic Reviews (identifier: CRD42020189686).</abstract><pub>Associação Paulista de Medicina - APM</pub><doi>10.1590/1516-3180.2021.0852.13062022</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1806-9460 |
ispartof | São Paulo medical journal, 2023-04, Vol.141 (2), p.154-167 |
issn | 1806-9460 |
language | por |
recordid | cdi_scielo_journals_S1516_31802023000200154 |
source | SciELO Brazil |
subjects | MEDICINE, GENERAL & INTERNAL |
title | Ultrasound techniques for the detection of developmental dysplasia of the hip: a systematic review and meta-analysis |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T10%3A04%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scielo&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Ultrasound%20techniques%20for%20the%20detection%20of%20developmental%20dysplasia%20of%20the%20hip:%20a%20systematic%20review%20and%20meta-analysis&rft.jtitle=S%C3%A3o%20Paulo%20medical%20journal&rft.au=Duarte,%20Marcio%20Lu%C3%ADs&rft.date=2023-04-01&rft.volume=141&rft.issue=2&rft.spage=154&rft.epage=167&rft.pages=154-167&rft.issn=1806-9460&rft_id=info:doi/10.1590/1516-3180.2021.0852.13062022&rft_dat=%3Cscielo%3ES1516_31802023000200154%3C/scielo%3E%3Cgrp_id%3Ecdi_FETCH-scielo_journals_S1516_318020230002001543%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_scielo_id=S1516_31802023000200154&rfr_iscdi=true |