Loading…
Degree of conversion of a flowable composite light-activated through ceramics of different shades and thicknesses
Abstract The cementation of thin ceramic veneers employing fluid light-activated resin-based materials is a common procedure in the dental practice. Aim: To evaluate the influence of ceramic thickness and shade on the degree of conversion (DC) of a flowable light-activated material. Methods: flowabl...
Saved in:
Published in: | Brazilian journal of oral sciences 2015-09, Vol.14 (3), p.230-233 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c3081-e7d3db5f8298ab8970aada834c4c2e4f083711f0de56b12f0b7a8ae7dd3e0d863 |
---|---|
cites | |
container_end_page | 233 |
container_issue | 3 |
container_start_page | 230 |
container_title | Brazilian journal of oral sciences |
container_volume | 14 |
creator | Furuse, Adilson Yoshio Glir, Daniel Hatschbach Rizzante, Fabio Antonio Piola Prochnow, Rayane Borges, Ana Flávia Sanches Gonzaga, Carla Castiglia |
description | Abstract The cementation of thin ceramic veneers employing fluid light-activated resin-based materials is a common procedure in the dental practice. Aim: To evaluate the influence of ceramic thickness and shade on the degree of conversion (DC) of a flowable light-activated material. Methods: flowable resin composite (Tetric N-Flow - shade A1) was light-activated through ceramic discs of two shades (IPS Classic - A1 and A3) in three thicknesses (0.5, 0.7 and 1.0 mm). For control, the resin composite was light-activated without ceramic interposition. DC was evaluated by FTIR (n=5). Data were analyzed by one-way ANOVA and Dunnett's T3 test (α=0.05). Results: Statistically significant differences between groups were observed (p |
doi_str_mv | 10.1590/1677-3225v14n3a11 |
format | article |
fullrecord | <record><control><sourceid>scielo_cross</sourceid><recordid>TN_cdi_scielo_journals_S1677_32252015000300230</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S1677_32252015000300230</scielo_id><sourcerecordid>S1677_32252015000300230</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3081-e7d3db5f8298ab8970aada834c4c2e4f083711f0de56b12f0b7a8ae7dd3e0d863</originalsourceid><addsrcrecordid>eNpNkMlOwzAQQC0EEqXwAdzyAyljO4t7RGWVKnEAztHEHjcuaVzstIi_J1Gh4jTrm5EeY9ccZjyfww0vyjKVQuR7nnUSOT9hk2Pv9F9-zi5iXANkosj4hH3e0SoQJd4m2nd7CtH5bqwwsa3_wrqlYbDZ-uh6Slq3avoUde_22JNJ-ib43apJNAXcOB1H0DhrKVDXJ7FBQzHBblx0-qOjGClesjOLbaSr3zhl7w_3b4undPny-Ly4XaZaguIplUaaOrdKzBXWal4CokElM51pQZkFJUvOLRjKi5oLC3WJCgfKSAKjCjlls8PdqB21vlr7XeiGh9Xr6KIaXQjgOQBIACFhAPgB0MHHGMhW2-A2GL4rDtUouTqCf5LlD2ylcEc</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Degree of conversion of a flowable composite light-activated through ceramics of different shades and thicknesses</title><source>SciELO</source><creator>Furuse, Adilson Yoshio ; Glir, Daniel Hatschbach ; Rizzante, Fabio Antonio Piola ; Prochnow, Rayane ; Borges, Ana Flávia Sanches ; Gonzaga, Carla Castiglia</creator><creatorcontrib>Furuse, Adilson Yoshio ; Glir, Daniel Hatschbach ; Rizzante, Fabio Antonio Piola ; Prochnow, Rayane ; Borges, Ana Flávia Sanches ; Gonzaga, Carla Castiglia</creatorcontrib><description>Abstract The cementation of thin ceramic veneers employing fluid light-activated resin-based materials is a common procedure in the dental practice. Aim: To evaluate the influence of ceramic thickness and shade on the degree of conversion (DC) of a flowable light-activated material. Methods: flowable resin composite (Tetric N-Flow - shade A1) was light-activated through ceramic discs of two shades (IPS Classic - A1 and A3) in three thicknesses (0.5, 0.7 and 1.0 mm). For control, the resin composite was light-activated without ceramic interposition. DC was evaluated by FTIR (n=5). Data were analyzed by one-way ANOVA and Dunnett's T3 test (α=0.05). Results: Statistically significant differences between groups were observed (p<0.001). Control group (without the interposition of ceramic) showed the highest mean for DC (71.9± 1.7). Considering the interposed ceramic disc groups, the highest DC values were obtained when 0.5 and 0.7 mm A1 ceramics were used (64.6±1.2 and 64.4 5.0, respectively) and the lowest DC values were obtained for 0.7 and 1 mm A3 ceramics (61.74±0.9 and 62.0±1.9, respectively). Conclusions: No flowable resin composite group with interposing ceramics reached a DC similar to the control group.</description><identifier>ISSN: 1677-3225</identifier><identifier>EISSN: 1677-3225</identifier><identifier>DOI: 10.1590/1677-3225v14n3a11</identifier><language>eng</language><publisher>Faculdade de Odontologia de Piracicaba - UNICAMP</publisher><subject>DENTISTRY, ORAL SURGERY & MEDICINE</subject><ispartof>Brazilian journal of oral sciences, 2015-09, Vol.14 (3), p.230-233</ispartof><rights>This work is licensed under a Creative Commons Attribution 4.0 International License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3081-e7d3db5f8298ab8970aada834c4c2e4f083711f0de56b12f0b7a8ae7dd3e0d863</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,24148,27922,27923</link.rule.ids></links><search><creatorcontrib>Furuse, Adilson Yoshio</creatorcontrib><creatorcontrib>Glir, Daniel Hatschbach</creatorcontrib><creatorcontrib>Rizzante, Fabio Antonio Piola</creatorcontrib><creatorcontrib>Prochnow, Rayane</creatorcontrib><creatorcontrib>Borges, Ana Flávia Sanches</creatorcontrib><creatorcontrib>Gonzaga, Carla Castiglia</creatorcontrib><title>Degree of conversion of a flowable composite light-activated through ceramics of different shades and thicknesses</title><title>Brazilian journal of oral sciences</title><addtitle>Braz. J. Oral Sci</addtitle><description>Abstract The cementation of thin ceramic veneers employing fluid light-activated resin-based materials is a common procedure in the dental practice. Aim: To evaluate the influence of ceramic thickness and shade on the degree of conversion (DC) of a flowable light-activated material. Methods: flowable resin composite (Tetric N-Flow - shade A1) was light-activated through ceramic discs of two shades (IPS Classic - A1 and A3) in three thicknesses (0.5, 0.7 and 1.0 mm). For control, the resin composite was light-activated without ceramic interposition. DC was evaluated by FTIR (n=5). Data were analyzed by one-way ANOVA and Dunnett's T3 test (α=0.05). Results: Statistically significant differences between groups were observed (p<0.001). Control group (without the interposition of ceramic) showed the highest mean for DC (71.9± 1.7). Considering the interposed ceramic disc groups, the highest DC values were obtained when 0.5 and 0.7 mm A1 ceramics were used (64.6±1.2 and 64.4 5.0, respectively) and the lowest DC values were obtained for 0.7 and 1 mm A3 ceramics (61.74±0.9 and 62.0±1.9, respectively). Conclusions: No flowable resin composite group with interposing ceramics reached a DC similar to the control group.</description><subject>DENTISTRY, ORAL SURGERY & MEDICINE</subject><issn>1677-3225</issn><issn>1677-3225</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNpNkMlOwzAQQC0EEqXwAdzyAyljO4t7RGWVKnEAztHEHjcuaVzstIi_J1Gh4jTrm5EeY9ccZjyfww0vyjKVQuR7nnUSOT9hk2Pv9F9-zi5iXANkosj4hH3e0SoQJd4m2nd7CtH5bqwwsa3_wrqlYbDZ-uh6Slq3avoUde_22JNJ-ib43apJNAXcOB1H0DhrKVDXJ7FBQzHBblx0-qOjGClesjOLbaSr3zhl7w_3b4undPny-Ly4XaZaguIplUaaOrdKzBXWal4CokElM51pQZkFJUvOLRjKi5oLC3WJCgfKSAKjCjlls8PdqB21vlr7XeiGh9Xr6KIaXQjgOQBIACFhAPgB0MHHGMhW2-A2GL4rDtUouTqCf5LlD2ylcEc</recordid><startdate>20150901</startdate><enddate>20150901</enddate><creator>Furuse, Adilson Yoshio</creator><creator>Glir, Daniel Hatschbach</creator><creator>Rizzante, Fabio Antonio Piola</creator><creator>Prochnow, Rayane</creator><creator>Borges, Ana Flávia Sanches</creator><creator>Gonzaga, Carla Castiglia</creator><general>Faculdade de Odontologia de Piracicaba - UNICAMP</general><scope>AAYXX</scope><scope>CITATION</scope><scope>GPN</scope></search><sort><creationdate>20150901</creationdate><title>Degree of conversion of a flowable composite light-activated through ceramics of different shades and thicknesses</title><author>Furuse, Adilson Yoshio ; Glir, Daniel Hatschbach ; Rizzante, Fabio Antonio Piola ; Prochnow, Rayane ; Borges, Ana Flávia Sanches ; Gonzaga, Carla Castiglia</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3081-e7d3db5f8298ab8970aada834c4c2e4f083711f0de56b12f0b7a8ae7dd3e0d863</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>DENTISTRY, ORAL SURGERY & MEDICINE</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Furuse, Adilson Yoshio</creatorcontrib><creatorcontrib>Glir, Daniel Hatschbach</creatorcontrib><creatorcontrib>Rizzante, Fabio Antonio Piola</creatorcontrib><creatorcontrib>Prochnow, Rayane</creatorcontrib><creatorcontrib>Borges, Ana Flávia Sanches</creatorcontrib><creatorcontrib>Gonzaga, Carla Castiglia</creatorcontrib><collection>CrossRef</collection><collection>SciELO</collection><jtitle>Brazilian journal of oral sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Furuse, Adilson Yoshio</au><au>Glir, Daniel Hatschbach</au><au>Rizzante, Fabio Antonio Piola</au><au>Prochnow, Rayane</au><au>Borges, Ana Flávia Sanches</au><au>Gonzaga, Carla Castiglia</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Degree of conversion of a flowable composite light-activated through ceramics of different shades and thicknesses</atitle><jtitle>Brazilian journal of oral sciences</jtitle><addtitle>Braz. J. Oral Sci</addtitle><date>2015-09-01</date><risdate>2015</risdate><volume>14</volume><issue>3</issue><spage>230</spage><epage>233</epage><pages>230-233</pages><issn>1677-3225</issn><eissn>1677-3225</eissn><abstract>Abstract The cementation of thin ceramic veneers employing fluid light-activated resin-based materials is a common procedure in the dental practice. Aim: To evaluate the influence of ceramic thickness and shade on the degree of conversion (DC) of a flowable light-activated material. Methods: flowable resin composite (Tetric N-Flow - shade A1) was light-activated through ceramic discs of two shades (IPS Classic - A1 and A3) in three thicknesses (0.5, 0.7 and 1.0 mm). For control, the resin composite was light-activated without ceramic interposition. DC was evaluated by FTIR (n=5). Data were analyzed by one-way ANOVA and Dunnett's T3 test (α=0.05). Results: Statistically significant differences between groups were observed (p<0.001). Control group (without the interposition of ceramic) showed the highest mean for DC (71.9± 1.7). Considering the interposed ceramic disc groups, the highest DC values were obtained when 0.5 and 0.7 mm A1 ceramics were used (64.6±1.2 and 64.4 5.0, respectively) and the lowest DC values were obtained for 0.7 and 1 mm A3 ceramics (61.74±0.9 and 62.0±1.9, respectively). Conclusions: No flowable resin composite group with interposing ceramics reached a DC similar to the control group.</abstract><pub>Faculdade de Odontologia de Piracicaba - UNICAMP</pub><doi>10.1590/1677-3225v14n3a11</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1677-3225 |
ispartof | Brazilian journal of oral sciences, 2015-09, Vol.14 (3), p.230-233 |
issn | 1677-3225 1677-3225 |
language | eng |
recordid | cdi_scielo_journals_S1677_32252015000300230 |
source | SciELO |
subjects | DENTISTRY, ORAL SURGERY & MEDICINE |
title | Degree of conversion of a flowable composite light-activated through ceramics of different shades and thicknesses |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T04%3A31%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scielo_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Degree%20of%20conversion%20of%20a%20flowable%20composite%20light-activated%20through%20ceramics%20of%20different%20shades%20and%20thicknesses&rft.jtitle=Brazilian%20journal%20of%20oral%20sciences&rft.au=Furuse,%20Adilson%20Yoshio&rft.date=2015-09-01&rft.volume=14&rft.issue=3&rft.spage=230&rft.epage=233&rft.pages=230-233&rft.issn=1677-3225&rft.eissn=1677-3225&rft_id=info:doi/10.1590/1677-3225v14n3a11&rft_dat=%3Cscielo_cross%3ES1677_32252015000300230%3C/scielo_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3081-e7d3db5f8298ab8970aada834c4c2e4f083711f0de56b12f0b7a8ae7dd3e0d863%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_scielo_id=S1677_32252015000300230&rfr_iscdi=true |