Loading…
Serum beta2-microglobulin values among healthy Brazilians using a DPC IMMULITE assay
The present study was designed to determine the normal range of serum beta 2-microglobulin (Sb2M) levels among healthy volunteers in Brazil. Levels of Sb2M are elevated in human immunodeficiency virus (HIV)-infected patients and have been shown to be the best predictor of HIV infection status and of...
Saved in:
Published in: | Clinics (São Paulo, Brazil) Brazil), 2005-02, Vol.60 (1), p.47-50 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 50 |
container_issue | 1 |
container_start_page | 47 |
container_title | Clinics (São Paulo, Brazil) |
container_volume | 60 |
creator | Filippin, Fabíola Branco Souza, Liliete Canes |
description | The present study was designed to determine the normal range of serum beta 2-microglobulin (Sb2M) levels among healthy volunteers in Brazil. Levels of Sb2M are elevated in human immunodeficiency virus (HIV)-infected patients and have been shown to be the best predictor of HIV infection status and of some malignant disorders, especially multiple myeloma. In order to achieve its optimal use in Brazilian clinical diagnosis, an adequate reference interval study was performed for Sb2M IMMULITE assay, based on the fact that its reference range limits were evaluated among European populations.
Ninety-six healthy blood donors were evaluated, and Sb2M levels were measured by chemiluminescent enzyme immunoassay using the IMMULITE automated analyzer.
A normal range of Sb2M values, established by a nonparametric statistical method, was 1.05 to 3.9 mg/mL, with the upper limit being higher than that reported elsewhere.
This study presented new data indicating that there is a significant difference between the current reference limits for Sb2M IMMULITE assay and those found in Brazil, providing evidence that significant differences in range of normal values may occur among different populations, and that these new values should be considered for Brazilian individuals. |
doi_str_mv | 10.1590/S1807-59322005000100010 |
format | article |
fullrecord | <record><control><sourceid>proquest_sciel</sourceid><recordid>TN_cdi_scielo_journals_S1807_59322005000100010</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S1807_59322005000100010</scielo_id><sourcerecordid>67750821</sourcerecordid><originalsourceid>FETCH-LOGICAL-p163t-4c8985a171e393dfce37068e6edf491a1395beb03fa804c2d86822879afde27e3</originalsourceid><addsrcrecordid>eNplkEtPwkAUhWehEUT_gs7KXXEenXa6VEQlgWgCrJvb9haGTDvYaU3w19uAunFxcxfnnPv4CLnlbMxVwu6XXLM4UIkUgjHFGOPHOiPDP2FALr3fMSYTGaoLMuBKS600H5LVEpuuohm2IILK5I3bWJd11tT0E2yHnkLl6g3dIth2e6CPDXwZa6D2tPOmF4A-vU_obLFYz2erKQXv4XBFzkuwHq9_-oisn6eryWswf3uZTR7mwZ5Hsg3CXCdaAY859ocVZY4yZpHGCIsyTDhwmagMMyZL0CzMRaEjLYSOEygLFDHKERmf5vrcoHXpznVN3S9Mj0jSf0j6wN0psG_cR_9cm1bG52gt1Og6n0ZxrJgWvDfe_Bi7rMIi3TemguaQ_oKT32uua8Q</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67750821</pqid></control><display><type>article</type><title>Serum beta2-microglobulin values among healthy Brazilians using a DPC IMMULITE assay</title><source>SciELO Brazil</source><source>ScienceDirect Additional Titles</source><creator>Filippin, Fabíola Branco ; Souza, Liliete Canes</creator><creatorcontrib>Filippin, Fabíola Branco ; Souza, Liliete Canes</creatorcontrib><description>The present study was designed to determine the normal range of serum beta 2-microglobulin (Sb2M) levels among healthy volunteers in Brazil. Levels of Sb2M are elevated in human immunodeficiency virus (HIV)-infected patients and have been shown to be the best predictor of HIV infection status and of some malignant disorders, especially multiple myeloma. In order to achieve its optimal use in Brazilian clinical diagnosis, an adequate reference interval study was performed for Sb2M IMMULITE assay, based on the fact that its reference range limits were evaluated among European populations.
Ninety-six healthy blood donors were evaluated, and Sb2M levels were measured by chemiluminescent enzyme immunoassay using the IMMULITE automated analyzer.
A normal range of Sb2M values, established by a nonparametric statistical method, was 1.05 to 3.9 mg/mL, with the upper limit being higher than that reported elsewhere.
This study presented new data indicating that there is a significant difference between the current reference limits for Sb2M IMMULITE assay and those found in Brazil, providing evidence that significant differences in range of normal values may occur among different populations, and that these new values should be considered for Brazilian individuals.</description><identifier>ISSN: 1807-5932</identifier><identifier>ISSN: 1980-5322</identifier><identifier>DOI: 10.1590/S1807-59322005000100010</identifier><identifier>PMID: 15838581</identifier><language>eng</language><publisher>Brazil: Faculdade de Medicina / USP</publisher><subject>Adult ; beta 2-Microglobulin - blood ; Biomarkers - blood ; Blood Donors ; Brazil ; Female ; HIV - immunology ; HIV Infections - blood ; HIV Infections - immunology ; Humans ; Immunoenzyme Techniques - methods ; Male ; MEDICINE, GENERAL & INTERNAL ; Middle Aged ; Reference Values ; Statistics, Nonparametric</subject><ispartof>Clinics (São Paulo, Brazil), 2005-02, Vol.60 (1), p.47-50</ispartof><rights>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,24150,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15838581$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Filippin, Fabíola Branco</creatorcontrib><creatorcontrib>Souza, Liliete Canes</creatorcontrib><title>Serum beta2-microglobulin values among healthy Brazilians using a DPC IMMULITE assay</title><title>Clinics (São Paulo, Brazil)</title><addtitle>Clinics (Sao Paulo)</addtitle><description>The present study was designed to determine the normal range of serum beta 2-microglobulin (Sb2M) levels among healthy volunteers in Brazil. Levels of Sb2M are elevated in human immunodeficiency virus (HIV)-infected patients and have been shown to be the best predictor of HIV infection status and of some malignant disorders, especially multiple myeloma. In order to achieve its optimal use in Brazilian clinical diagnosis, an adequate reference interval study was performed for Sb2M IMMULITE assay, based on the fact that its reference range limits were evaluated among European populations.
Ninety-six healthy blood donors were evaluated, and Sb2M levels were measured by chemiluminescent enzyme immunoassay using the IMMULITE automated analyzer.
A normal range of Sb2M values, established by a nonparametric statistical method, was 1.05 to 3.9 mg/mL, with the upper limit being higher than that reported elsewhere.
This study presented new data indicating that there is a significant difference between the current reference limits for Sb2M IMMULITE assay and those found in Brazil, providing evidence that significant differences in range of normal values may occur among different populations, and that these new values should be considered for Brazilian individuals.</description><subject>Adult</subject><subject>beta 2-Microglobulin - blood</subject><subject>Biomarkers - blood</subject><subject>Blood Donors</subject><subject>Brazil</subject><subject>Female</subject><subject>HIV - immunology</subject><subject>HIV Infections - blood</subject><subject>HIV Infections - immunology</subject><subject>Humans</subject><subject>Immunoenzyme Techniques - methods</subject><subject>Male</subject><subject>MEDICINE, GENERAL & INTERNAL</subject><subject>Middle Aged</subject><subject>Reference Values</subject><subject>Statistics, Nonparametric</subject><issn>1807-5932</issn><issn>1980-5322</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNplkEtPwkAUhWehEUT_gs7KXXEenXa6VEQlgWgCrJvb9haGTDvYaU3w19uAunFxcxfnnPv4CLnlbMxVwu6XXLM4UIkUgjHFGOPHOiPDP2FALr3fMSYTGaoLMuBKS600H5LVEpuuohm2IILK5I3bWJd11tT0E2yHnkLl6g3dIth2e6CPDXwZa6D2tPOmF4A-vU_obLFYz2erKQXv4XBFzkuwHq9_-oisn6eryWswf3uZTR7mwZ5Hsg3CXCdaAY859ocVZY4yZpHGCIsyTDhwmagMMyZL0CzMRaEjLYSOEygLFDHKERmf5vrcoHXpznVN3S9Mj0jSf0j6wN0psG_cR_9cm1bG52gt1Og6n0ZxrJgWvDfe_Bi7rMIi3TemguaQ_oKT32uua8Q</recordid><startdate>20050201</startdate><enddate>20050201</enddate><creator>Filippin, Fabíola Branco</creator><creator>Souza, Liliete Canes</creator><general>Faculdade de Medicina / USP</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope><scope>GPN</scope></search><sort><creationdate>20050201</creationdate><title>Serum beta2-microglobulin values among healthy Brazilians using a DPC IMMULITE assay</title><author>Filippin, Fabíola Branco ; Souza, Liliete Canes</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p163t-4c8985a171e393dfce37068e6edf491a1395beb03fa804c2d86822879afde27e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Adult</topic><topic>beta 2-Microglobulin - blood</topic><topic>Biomarkers - blood</topic><topic>Blood Donors</topic><topic>Brazil</topic><topic>Female</topic><topic>HIV - immunology</topic><topic>HIV Infections - blood</topic><topic>HIV Infections - immunology</topic><topic>Humans</topic><topic>Immunoenzyme Techniques - methods</topic><topic>Male</topic><topic>MEDICINE, GENERAL & INTERNAL</topic><topic>Middle Aged</topic><topic>Reference Values</topic><topic>Statistics, Nonparametric</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Filippin, Fabíola Branco</creatorcontrib><creatorcontrib>Souza, Liliete Canes</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><collection>SciELO</collection><jtitle>Clinics (São Paulo, Brazil)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Filippin, Fabíola Branco</au><au>Souza, Liliete Canes</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Serum beta2-microglobulin values among healthy Brazilians using a DPC IMMULITE assay</atitle><jtitle>Clinics (São Paulo, Brazil)</jtitle><addtitle>Clinics (Sao Paulo)</addtitle><date>2005-02-01</date><risdate>2005</risdate><volume>60</volume><issue>1</issue><spage>47</spage><epage>50</epage><pages>47-50</pages><issn>1807-5932</issn><issn>1980-5322</issn><abstract>The present study was designed to determine the normal range of serum beta 2-microglobulin (Sb2M) levels among healthy volunteers in Brazil. Levels of Sb2M are elevated in human immunodeficiency virus (HIV)-infected patients and have been shown to be the best predictor of HIV infection status and of some malignant disorders, especially multiple myeloma. In order to achieve its optimal use in Brazilian clinical diagnosis, an adequate reference interval study was performed for Sb2M IMMULITE assay, based on the fact that its reference range limits were evaluated among European populations.
Ninety-six healthy blood donors were evaluated, and Sb2M levels were measured by chemiluminescent enzyme immunoassay using the IMMULITE automated analyzer.
A normal range of Sb2M values, established by a nonparametric statistical method, was 1.05 to 3.9 mg/mL, with the upper limit being higher than that reported elsewhere.
This study presented new data indicating that there is a significant difference between the current reference limits for Sb2M IMMULITE assay and those found in Brazil, providing evidence that significant differences in range of normal values may occur among different populations, and that these new values should be considered for Brazilian individuals.</abstract><cop>Brazil</cop><pub>Faculdade de Medicina / USP</pub><pmid>15838581</pmid><doi>10.1590/S1807-59322005000100010</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1807-5932 |
ispartof | Clinics (São Paulo, Brazil), 2005-02, Vol.60 (1), p.47-50 |
issn | 1807-5932 1980-5322 |
language | eng |
recordid | cdi_scielo_journals_S1807_59322005000100010 |
source | SciELO Brazil; ScienceDirect Additional Titles |
subjects | Adult beta 2-Microglobulin - blood Biomarkers - blood Blood Donors Brazil Female HIV - immunology HIV Infections - blood HIV Infections - immunology Humans Immunoenzyme Techniques - methods Male MEDICINE, GENERAL & INTERNAL Middle Aged Reference Values Statistics, Nonparametric |
title | Serum beta2-microglobulin values among healthy Brazilians using a DPC IMMULITE assay |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T22%3A12%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_sciel&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Serum%20beta2-microglobulin%20values%20among%20healthy%20Brazilians%20using%20a%20DPC%20IMMULITE%20assay&rft.jtitle=Clinics%20(S%C3%A3o%20Paulo,%20Brazil)&rft.au=Filippin,%20Fab%C3%ADola%20Branco&rft.date=2005-02-01&rft.volume=60&rft.issue=1&rft.spage=47&rft.epage=50&rft.pages=47-50&rft.issn=1807-5932&rft_id=info:doi/10.1590/S1807-59322005000100010&rft_dat=%3Cproquest_sciel%3E67750821%3C/proquest_sciel%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-p163t-4c8985a171e393dfce37068e6edf491a1395beb03fa804c2d86822879afde27e3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=67750821&rft_id=info:pmid/15838581&rft_scielo_id=S1807_59322005000100010&rfr_iscdi=true |