Resistance to fracture due to cyclic fatigue of stainless steel manual files and its association to surface roughness
The aim of this study was to evaluate the possible association between the roughness of 5 brands of stainless steel endodontic files and their resistance to fracture due to cyclic fatigue. The study included five different brands of stainless steel endodontic files: SybroEndo Triple-Flex Files (Kerr...
Saved in:
Published in: | Acta odontológica latinoamericana 2021-04, Vol.34 (1), p.18-26 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 26 |
container_issue | 1 |
container_start_page | 18 |
container_title | Acta odontológica latinoamericana |
container_volume | 34 |
creator | Niño-Barrera, Javier L Sánchez-Alemán, José A Gamboa-Martinez, Luis Cortes-Rodriguez, Carlos |
description | The aim of this study was to evaluate the possible association between the roughness of 5 brands of stainless steel endodontic files and their resistance to fracture due to cyclic fatigue. The study included five different brands of stainless steel endodontic files: SybroEndo Triple-Flex Files (Kerr, Glendora, USA), Ready Steel K-Flexofile (Dentsply Sirona, Ballaigues, Switzerland), Mani Flexile Files (Mani, Tochigi- Ken, Japan), FKG K-Files (FKG, La Chaux-de-Fonds, Switzerland) and Zipperer Flexicut Files (VDW, Munich, Germany). Twelve files per brand (total 60 files) were evaluated. File surface roughness over an area (Sa) was quantified using a focus variation microscope. Then the files were subject to a cyclical fatigue test to determine the number cycles to fracture due to fatigue and length of fractured fragment. Finally, fractographic analysis was performed using a scanning electron microscope. The electropolished Ready Steel K-Flexofile® files had the highest roughness according to Sa parameters, though they also had the highest resistance to fracture due to cyclic fatigue and the longest fractured fragment. Moderate positive correlation was found between fractured fragment length and roughness. The fractured surface showed characteristics of ductile fracture with cracks and plastic deformation. The electropolished stainless steel Ready Steel K-Flexofile® files were the most resistant to fracture due to cyclic fatigue even though they had highest surface roughness. |
doi_str_mv | 10.54589/aol.34/1/018 |
format | article |
fullrecord | <record><control><sourceid>proquest_sciel</sourceid><recordid>TN_cdi_scielo_journals_S1852_48342021000100018</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S1852_48342021000100018</scielo_id><sourcerecordid>2542361492</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2428-1b49aa436131bc2dec40bf4cb2bb0728e43240295b3f3c9466d9883cff75aed83</originalsourceid><addsrcrecordid>eNpNUblOAzEQtRCII1DSIpc0m_iYzXpLFHFJkZA4asvrtcHIWQd7XeTvcRJAFKM59N6b0TyELimZ1lCLdqaCn3KY0Rmh4gCdUlGzCgSHw3_1CTpL6ZOQOWkEOUYnHChvmgZOUX42yaVRDdrgMWAblR5zNLjPu15vtHcaWzW69zIJFhesG7xJqVTGeLxSQ1YeW1dmWA09dmPJKQXtCikMW5WUo1VlQQz5_WMo3HN0ZJVP5uInT9Db3e3r4qFaPt0_Lm6WlWbAREU7aJUCPqecdpr1RgPpLOiOdR1pmDDAGRDW1h23XLcwn_etEFxb29TK9IJP0HSvm7QzPsjPkONQFsqX7Wvk9jWMMEoI2cWWcL0nrGP4yiaNcuWSNt6rwYScJKuBlXOgZQVa7aE6hpSisXId3UrFjaRE7qyRxRrJQVK5l776kc7dyvR_6F8v-DdM4Ykm</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2542361492</pqid></control><display><type>article</type><title>Resistance to fracture due to cyclic fatigue of stainless steel manual files and its association to surface roughness</title><source>Open Access: PubMed Central</source><creator>Niño-Barrera, Javier L ; Sánchez-Alemán, José A ; Gamboa-Martinez, Luis ; Cortes-Rodriguez, Carlos</creator><creatorcontrib>Niño-Barrera, Javier L ; Sánchez-Alemán, José A ; Gamboa-Martinez, Luis ; Cortes-Rodriguez, Carlos</creatorcontrib><description>The aim of this study was to evaluate the possible association between the roughness of 5 brands of stainless steel endodontic files and their resistance to fracture due to cyclic fatigue. The study included five different brands of stainless steel endodontic files: SybroEndo Triple-Flex Files (Kerr, Glendora, USA), Ready Steel K-Flexofile (Dentsply Sirona, Ballaigues, Switzerland), Mani Flexile Files (Mani, Tochigi- Ken, Japan), FKG K-Files (FKG, La Chaux-de-Fonds, Switzerland) and Zipperer Flexicut Files (VDW, Munich, Germany). Twelve files per brand (total 60 files) were evaluated. File surface roughness over an area (Sa) was quantified using a focus variation microscope. Then the files were subject to a cyclical fatigue test to determine the number cycles to fracture due to fatigue and length of fractured fragment. Finally, fractographic analysis was performed using a scanning electron microscope. The electropolished Ready Steel K-Flexofile® files had the highest roughness according to Sa parameters, though they also had the highest resistance to fracture due to cyclic fatigue and the longest fractured fragment. Moderate positive correlation was found between fractured fragment length and roughness. The fractured surface showed characteristics of ductile fracture with cracks and plastic deformation. The electropolished stainless steel Ready Steel K-Flexofile® files were the most resistant to fracture due to cyclic fatigue even though they had highest surface roughness.</description><identifier>ISSN: 1852-4834</identifier><identifier>EISSN: 1852-4834</identifier><identifier>DOI: 10.54589/aol.34/1/018</identifier><identifier>PMID: 34137774</identifier><language>eng</language><publisher>Argentina: Sociedad Argentina de Investigación Odontológica</publisher><subject>Dental Alloys ; Dental Instruments ; DENTISTRY, ORAL SURGERY & MEDICINE ; Equipment Design ; Equipment Failure ; Materials Testing ; Nickel ; Root Canal Preparation ; Stainless Steel ; Titanium</subject><ispartof>Acta odontológica latinoamericana, 2021-04, Vol.34 (1), p.18-26</ispartof><rights>Sociedad Argentina de Investigación Odontológica.</rights><rights>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/34137774$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Niño-Barrera, Javier L</creatorcontrib><creatorcontrib>Sánchez-Alemán, José A</creatorcontrib><creatorcontrib>Gamboa-Martinez, Luis</creatorcontrib><creatorcontrib>Cortes-Rodriguez, Carlos</creatorcontrib><title>Resistance to fracture due to cyclic fatigue of stainless steel manual files and its association to surface roughness</title><title>Acta odontológica latinoamericana</title><addtitle>Acta Odontol Latinoam</addtitle><description>The aim of this study was to evaluate the possible association between the roughness of 5 brands of stainless steel endodontic files and their resistance to fracture due to cyclic fatigue. The study included five different brands of stainless steel endodontic files: SybroEndo Triple-Flex Files (Kerr, Glendora, USA), Ready Steel K-Flexofile (Dentsply Sirona, Ballaigues, Switzerland), Mani Flexile Files (Mani, Tochigi- Ken, Japan), FKG K-Files (FKG, La Chaux-de-Fonds, Switzerland) and Zipperer Flexicut Files (VDW, Munich, Germany). Twelve files per brand (total 60 files) were evaluated. File surface roughness over an area (Sa) was quantified using a focus variation microscope. Then the files were subject to a cyclical fatigue test to determine the number cycles to fracture due to fatigue and length of fractured fragment. Finally, fractographic analysis was performed using a scanning electron microscope. The electropolished Ready Steel K-Flexofile® files had the highest roughness according to Sa parameters, though they also had the highest resistance to fracture due to cyclic fatigue and the longest fractured fragment. Moderate positive correlation was found between fractured fragment length and roughness. The fractured surface showed characteristics of ductile fracture with cracks and plastic deformation. The electropolished stainless steel Ready Steel K-Flexofile® files were the most resistant to fracture due to cyclic fatigue even though they had highest surface roughness.</description><subject>Dental Alloys</subject><subject>Dental Instruments</subject><subject>DENTISTRY, ORAL SURGERY & MEDICINE</subject><subject>Equipment Design</subject><subject>Equipment Failure</subject><subject>Materials Testing</subject><subject>Nickel</subject><subject>Root Canal Preparation</subject><subject>Stainless Steel</subject><subject>Titanium</subject><issn>1852-4834</issn><issn>1852-4834</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNpNUblOAzEQtRCII1DSIpc0m_iYzXpLFHFJkZA4asvrtcHIWQd7XeTvcRJAFKM59N6b0TyELimZ1lCLdqaCn3KY0Rmh4gCdUlGzCgSHw3_1CTpL6ZOQOWkEOUYnHChvmgZOUX42yaVRDdrgMWAblR5zNLjPu15vtHcaWzW69zIJFhesG7xJqVTGeLxSQ1YeW1dmWA09dmPJKQXtCikMW5WUo1VlQQz5_WMo3HN0ZJVP5uInT9Db3e3r4qFaPt0_Lm6WlWbAREU7aJUCPqecdpr1RgPpLOiOdR1pmDDAGRDW1h23XLcwn_etEFxb29TK9IJP0HSvm7QzPsjPkONQFsqX7Wvk9jWMMEoI2cWWcL0nrGP4yiaNcuWSNt6rwYScJKuBlXOgZQVa7aE6hpSisXId3UrFjaRE7qyRxRrJQVK5l776kc7dyvR_6F8v-DdM4Ykm</recordid><startdate>20210401</startdate><enddate>20210401</enddate><creator>Niño-Barrera, Javier L</creator><creator>Sánchez-Alemán, José A</creator><creator>Gamboa-Martinez, Luis</creator><creator>Cortes-Rodriguez, Carlos</creator><general>Sociedad Argentina de Investigación Odontológica</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>GPN</scope></search><sort><creationdate>20210401</creationdate><title>Resistance to fracture due to cyclic fatigue of stainless steel manual files and its association to surface roughness</title><author>Niño-Barrera, Javier L ; Sánchez-Alemán, José A ; Gamboa-Martinez, Luis ; Cortes-Rodriguez, Carlos</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2428-1b49aa436131bc2dec40bf4cb2bb0728e43240295b3f3c9466d9883cff75aed83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Dental Alloys</topic><topic>Dental Instruments</topic><topic>DENTISTRY, ORAL SURGERY & MEDICINE</topic><topic>Equipment Design</topic><topic>Equipment Failure</topic><topic>Materials Testing</topic><topic>Nickel</topic><topic>Root Canal Preparation</topic><topic>Stainless Steel</topic><topic>Titanium</topic><toplevel>online_resources</toplevel><creatorcontrib>Niño-Barrera, Javier L</creatorcontrib><creatorcontrib>Sánchez-Alemán, José A</creatorcontrib><creatorcontrib>Gamboa-Martinez, Luis</creatorcontrib><creatorcontrib>Cortes-Rodriguez, Carlos</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>SciELO</collection><jtitle>Acta odontológica latinoamericana</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Niño-Barrera, Javier L</au><au>Sánchez-Alemán, José A</au><au>Gamboa-Martinez, Luis</au><au>Cortes-Rodriguez, Carlos</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Resistance to fracture due to cyclic fatigue of stainless steel manual files and its association to surface roughness</atitle><jtitle>Acta odontológica latinoamericana</jtitle><addtitle>Acta Odontol Latinoam</addtitle><date>2021-04-01</date><risdate>2021</risdate><volume>34</volume><issue>1</issue><spage>18</spage><epage>26</epage><pages>18-26</pages><issn>1852-4834</issn><eissn>1852-4834</eissn><abstract>The aim of this study was to evaluate the possible association between the roughness of 5 brands of stainless steel endodontic files and their resistance to fracture due to cyclic fatigue. The study included five different brands of stainless steel endodontic files: SybroEndo Triple-Flex Files (Kerr, Glendora, USA), Ready Steel K-Flexofile (Dentsply Sirona, Ballaigues, Switzerland), Mani Flexile Files (Mani, Tochigi- Ken, Japan), FKG K-Files (FKG, La Chaux-de-Fonds, Switzerland) and Zipperer Flexicut Files (VDW, Munich, Germany). Twelve files per brand (total 60 files) were evaluated. File surface roughness over an area (Sa) was quantified using a focus variation microscope. Then the files were subject to a cyclical fatigue test to determine the number cycles to fracture due to fatigue and length of fractured fragment. Finally, fractographic analysis was performed using a scanning electron microscope. The electropolished Ready Steel K-Flexofile® files had the highest roughness according to Sa parameters, though they also had the highest resistance to fracture due to cyclic fatigue and the longest fractured fragment. Moderate positive correlation was found between fractured fragment length and roughness. The fractured surface showed characteristics of ductile fracture with cracks and plastic deformation. The electropolished stainless steel Ready Steel K-Flexofile® files were the most resistant to fracture due to cyclic fatigue even though they had highest surface roughness.</abstract><cop>Argentina</cop><pub>Sociedad Argentina de Investigación Odontológica</pub><pmid>34137774</pmid><doi>10.54589/aol.34/1/018</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1852-4834 |
ispartof | Acta odontológica latinoamericana, 2021-04, Vol.34 (1), p.18-26 |
issn | 1852-4834 1852-4834 |
language | eng |
recordid | cdi_scielo_journals_S1852_48342021000100018 |
source | Open Access: PubMed Central |
subjects | Dental Alloys Dental Instruments DENTISTRY, ORAL SURGERY & MEDICINE Equipment Design Equipment Failure Materials Testing Nickel Root Canal Preparation Stainless Steel Titanium |
title | Resistance to fracture due to cyclic fatigue of stainless steel manual files and its association to surface roughness |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T04%3A37%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_sciel&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Resistance%20to%20fracture%20due%20to%20cyclic%20fatigue%20of%20stainless%20steel%20manual%20files%20and%20its%20association%20to%20surface%20roughness&rft.jtitle=Acta%20odontolo%CC%81gica%20latinoamericana&rft.au=Ni%C3%B1o-Barrera,%20Javier%20L&rft.date=2021-04-01&rft.volume=34&rft.issue=1&rft.spage=18&rft.epage=26&rft.pages=18-26&rft.issn=1852-4834&rft.eissn=1852-4834&rft_id=info:doi/10.54589/aol.34/1/018&rft_dat=%3Cproquest_sciel%3E2542361492%3C/proquest_sciel%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c2428-1b49aa436131bc2dec40bf4cb2bb0728e43240295b3f3c9466d9883cff75aed83%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2542361492&rft_id=info:pmid/34137774&rft_scielo_id=S1852_48342021000100018&rfr_iscdi=true |