Loading…

The effect of different exposure parameters on proximal caries detection using the Kodak 9000 3D CBCT system

ABSTRACT Objective: The objective of study was to evaluate the diagnostic quality of CBCT images for caries lesions detection using different exposure parameters. Methods: Sixty extracted human teeth were selected and scanned using Kodak 9000 3D CBCT system, with the following exposure parameters co...

Full description

Saved in:
Bibliographic Details
Published in:RGO - Revista Gaúcha de Odontologia 2017-12, Vol.65 (4), p.315-320
Main Authors: GONZAGA, Amanda Katarinny Goes, PEIXOTO, Larissa Rangel, OLIVEIRA, Luciana Soares de Andrade Freitas, MELO, Saulo Leonardo Sousa, CAMPOS, Paulo Sérgio Flores, MELO, Daniela Pita de
Format: Article
Language:eng ; por
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c1426-ee4dc2f1339a7fe74c2cc6539f08beba9e6786283ae4e4385048f681943a658d3
container_end_page 320
container_issue 4
container_start_page 315
container_title RGO - Revista Gaúcha de Odontologia
container_volume 65
creator GONZAGA, Amanda Katarinny Goes
PEIXOTO, Larissa Rangel
OLIVEIRA, Luciana Soares de Andrade Freitas
MELO, Saulo Leonardo Sousa
CAMPOS, Paulo Sérgio Flores
MELO, Daniela Pita de
description ABSTRACT Objective: The objective of study was to evaluate the diagnostic quality of CBCT images for caries lesions detection using different exposure parameters. Methods: Sixty extracted human teeth were selected and scanned using Kodak 9000 3D CBCT system, with the following exposure parameters combinations: 74 kV, 10mA; 74 kV, 12mA; 74 kV, 8 mA; 70 kV, 10 mA; 70kV, 12 mA; 70 kV e 8 mA; 70 kV, 6.3 mA. Two observers evaluated the images for caries presence using CS 3D Imaging Software. Each observer scored the proximal surfaces of each tooth on a 5-point scale. The scores were compared to histological sections used as gold standard. Accuracy for caries lesion detection was assessed for each exposure parameter combination and evaluated by means of ROC curve analysis. Results: The mean values for the areas under the ROC curves for each exposure parameter combination varied from 0.35 to 0.60. There was no statistical significant difference among protocols 1, 2, 4, 6 and 7. However, protocols 3 and 5 differed from all protocols. Conclusion: Although the highest dose protocol was the most efficient for proximal caries detection, the lowest dose protocol should be chosen based on the ALADA principle. RESUMO Objetivo: Avaliar a qualidade de diagnóstico de imagens de TCFC para detecção de lesões de cárie utilizando parâmetros de exposição diferentes. Métodos: Sessenta dentes humanos extraídos foram selecionados e digitalizados usando o sistema Kodak 9000 3D TCFC, com as seguintes combinações de parâmetros de exposição: 74 kV, 10 mA; 74 kV, 12 mA; 74 kV, 8 mA70 kV, 10 mA; 70 kV, 12 mA; 70 kV e 8 mA; 70 kV, 6,3 mA. Dois observadores avaliaram as imagens para a presença de cárie utilizando o CS 3D Imaging Software. Cada observador pontuou as superfícies proximais de cada dente em uma escala de 5 pontos. Os escores foram comparados com cortes histológicos, utilizados como padrão-ouro. A precisão para detecção de lesões de cárie foi analisada para cada combinação de parâmetros de exposição e avaliada por meio de análise da curva ROC. Resultados: Os valores médios para as áreas sob as curvas ROC para cada combinação de parâmetro de exposição variou de 0,35-0,60. Não houve diferença estatística significativa entre os protocolos 1, 2, 4, 6 e 7. No entanto, os protocolos 3 e 5 diferem de todos os protocolos. Conclusão: Embora o protocolo de dose mais elevada foi o mais eficiente para a detecção da cárie proximal, o protocolo de dose mais baixa deverá ser escolhido com bas
doi_str_mv 10.1590/1981-863720170002000053256
format article
fullrecord <record><control><sourceid>scielo_cross</sourceid><recordid>TN_cdi_scielo_journals_S1981_86372017000400315</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S1981_86372017000400315</scielo_id><sourcerecordid>S1981_86372017000400315</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1426-ee4dc2f1339a7fe74c2cc6539f08beba9e6786283ae4e4385048f681943a658d3</originalsourceid><addsrcrecordid>eNpdkMtOwzAQRS0EElXpP1jsU8aPODY7CE9RiQVlHbnOGAJpEtmp1P49rooAsRjNSFf3zswh5JzBnOUGLpjRLNNKFBxYAQA8FeSC5-qITH7EYzIBBiJTpmCnZBZjswKQBefSiAlpl-9I0Xt0I-09rZs0BuxGituhj5uAdLDBrnHEEGnf0SH022ZtW-psaDDSOilubJKyiU33RscU99TX9pOadAwVN7S8Lpc07uKI6zNy4m0bcfbdp-T17nZZPmSL5_vH8mqROSa5yhBl7bhnQhhbeCyk486pXBgPeoUra1AVWnEtLEqUQucgtVeaGSmsynUtpmR-yI2uwbavPvpN6NLC6mVPpfqDTAIIlifD5cHgQh9jQF8NIX0ZdhWDas-6-m_8ZS2-AJeWbqc</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>The effect of different exposure parameters on proximal caries detection using the Kodak 9000 3D CBCT system</title><source>SciELO Brazil</source><creator>GONZAGA, Amanda Katarinny Goes ; PEIXOTO, Larissa Rangel ; OLIVEIRA, Luciana Soares de Andrade Freitas ; MELO, Saulo Leonardo Sousa ; CAMPOS, Paulo Sérgio Flores ; MELO, Daniela Pita de</creator><creatorcontrib>GONZAGA, Amanda Katarinny Goes ; PEIXOTO, Larissa Rangel ; OLIVEIRA, Luciana Soares de Andrade Freitas ; MELO, Saulo Leonardo Sousa ; CAMPOS, Paulo Sérgio Flores ; MELO, Daniela Pita de</creatorcontrib><description>ABSTRACT Objective: The objective of study was to evaluate the diagnostic quality of CBCT images for caries lesions detection using different exposure parameters. Methods: Sixty extracted human teeth were selected and scanned using Kodak 9000 3D CBCT system, with the following exposure parameters combinations: 74 kV, 10mA; 74 kV, 12mA; 74 kV, 8 mA; 70 kV, 10 mA; 70kV, 12 mA; 70 kV e 8 mA; 70 kV, 6.3 mA. Two observers evaluated the images for caries presence using CS 3D Imaging Software. Each observer scored the proximal surfaces of each tooth on a 5-point scale. The scores were compared to histological sections used as gold standard. Accuracy for caries lesion detection was assessed for each exposure parameter combination and evaluated by means of ROC curve analysis. Results: The mean values for the areas under the ROC curves for each exposure parameter combination varied from 0.35 to 0.60. There was no statistical significant difference among protocols 1, 2, 4, 6 and 7. However, protocols 3 and 5 differed from all protocols. Conclusion: Although the highest dose protocol was the most efficient for proximal caries detection, the lowest dose protocol should be chosen based on the ALADA principle. RESUMO Objetivo: Avaliar a qualidade de diagnóstico de imagens de TCFC para detecção de lesões de cárie utilizando parâmetros de exposição diferentes. Métodos: Sessenta dentes humanos extraídos foram selecionados e digitalizados usando o sistema Kodak 9000 3D TCFC, com as seguintes combinações de parâmetros de exposição: 74 kV, 10 mA; 74 kV, 12 mA; 74 kV, 8 mA70 kV, 10 mA; 70 kV, 12 mA; 70 kV e 8 mA; 70 kV, 6,3 mA. Dois observadores avaliaram as imagens para a presença de cárie utilizando o CS 3D Imaging Software. Cada observador pontuou as superfícies proximais de cada dente em uma escala de 5 pontos. Os escores foram comparados com cortes histológicos, utilizados como padrão-ouro. A precisão para detecção de lesões de cárie foi analisada para cada combinação de parâmetros de exposição e avaliada por meio de análise da curva ROC. Resultados: Os valores médios para as áreas sob as curvas ROC para cada combinação de parâmetro de exposição variou de 0,35-0,60. Não houve diferença estatística significativa entre os protocolos 1, 2, 4, 6 e 7. No entanto, os protocolos 3 e 5 diferem de todos os protocolos. Conclusão: Embora o protocolo de dose mais elevada foi o mais eficiente para a detecção da cárie proximal, o protocolo de dose mais baixa deverá ser escolhido com base no princípio ALADA.</description><identifier>ISSN: 0103-6971</identifier><identifier>ISSN: 1981-8637</identifier><identifier>EISSN: 1981-8637</identifier><identifier>DOI: 10.1590/1981-863720170002000053256</identifier><language>eng ; por</language><publisher>Faculdade São Leopoldo Mandic</publisher><subject>DENTISTRY, ORAL SURGERY &amp; MEDICINE</subject><ispartof>RGO - Revista Gaúcha de Odontologia, 2017-12, Vol.65 (4), p.315-320</ispartof><rights>This work is licensed under a Creative Commons Attribution 4.0 International License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1426-ee4dc2f1339a7fe74c2cc6539f08beba9e6786283ae4e4385048f681943a658d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,24129,27901,27902</link.rule.ids></links><search><creatorcontrib>GONZAGA, Amanda Katarinny Goes</creatorcontrib><creatorcontrib>PEIXOTO, Larissa Rangel</creatorcontrib><creatorcontrib>OLIVEIRA, Luciana Soares de Andrade Freitas</creatorcontrib><creatorcontrib>MELO, Saulo Leonardo Sousa</creatorcontrib><creatorcontrib>CAMPOS, Paulo Sérgio Flores</creatorcontrib><creatorcontrib>MELO, Daniela Pita de</creatorcontrib><title>The effect of different exposure parameters on proximal caries detection using the Kodak 9000 3D CBCT system</title><title>RGO - Revista Gaúcha de Odontologia</title><addtitle>RGO, Rev. Gaúch. Odontol</addtitle><description>ABSTRACT Objective: The objective of study was to evaluate the diagnostic quality of CBCT images for caries lesions detection using different exposure parameters. Methods: Sixty extracted human teeth were selected and scanned using Kodak 9000 3D CBCT system, with the following exposure parameters combinations: 74 kV, 10mA; 74 kV, 12mA; 74 kV, 8 mA; 70 kV, 10 mA; 70kV, 12 mA; 70 kV e 8 mA; 70 kV, 6.3 mA. Two observers evaluated the images for caries presence using CS 3D Imaging Software. Each observer scored the proximal surfaces of each tooth on a 5-point scale. The scores were compared to histological sections used as gold standard. Accuracy for caries lesion detection was assessed for each exposure parameter combination and evaluated by means of ROC curve analysis. Results: The mean values for the areas under the ROC curves for each exposure parameter combination varied from 0.35 to 0.60. There was no statistical significant difference among protocols 1, 2, 4, 6 and 7. However, protocols 3 and 5 differed from all protocols. Conclusion: Although the highest dose protocol was the most efficient for proximal caries detection, the lowest dose protocol should be chosen based on the ALADA principle. RESUMO Objetivo: Avaliar a qualidade de diagnóstico de imagens de TCFC para detecção de lesões de cárie utilizando parâmetros de exposição diferentes. Métodos: Sessenta dentes humanos extraídos foram selecionados e digitalizados usando o sistema Kodak 9000 3D TCFC, com as seguintes combinações de parâmetros de exposição: 74 kV, 10 mA; 74 kV, 12 mA; 74 kV, 8 mA70 kV, 10 mA; 70 kV, 12 mA; 70 kV e 8 mA; 70 kV, 6,3 mA. Dois observadores avaliaram as imagens para a presença de cárie utilizando o CS 3D Imaging Software. Cada observador pontuou as superfícies proximais de cada dente em uma escala de 5 pontos. Os escores foram comparados com cortes histológicos, utilizados como padrão-ouro. A precisão para detecção de lesões de cárie foi analisada para cada combinação de parâmetros de exposição e avaliada por meio de análise da curva ROC. Resultados: Os valores médios para as áreas sob as curvas ROC para cada combinação de parâmetro de exposição variou de 0,35-0,60. Não houve diferença estatística significativa entre os protocolos 1, 2, 4, 6 e 7. No entanto, os protocolos 3 e 5 diferem de todos os protocolos. Conclusão: Embora o protocolo de dose mais elevada foi o mais eficiente para a detecção da cárie proximal, o protocolo de dose mais baixa deverá ser escolhido com base no princípio ALADA.</description><subject>DENTISTRY, ORAL SURGERY &amp; MEDICINE</subject><issn>0103-6971</issn><issn>1981-8637</issn><issn>1981-8637</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNpdkMtOwzAQRS0EElXpP1jsU8aPODY7CE9RiQVlHbnOGAJpEtmp1P49rooAsRjNSFf3zswh5JzBnOUGLpjRLNNKFBxYAQA8FeSC5-qITH7EYzIBBiJTpmCnZBZjswKQBefSiAlpl-9I0Xt0I-09rZs0BuxGituhj5uAdLDBrnHEEGnf0SH022ZtW-psaDDSOilubJKyiU33RscU99TX9pOadAwVN7S8Lpc07uKI6zNy4m0bcfbdp-T17nZZPmSL5_vH8mqROSa5yhBl7bhnQhhbeCyk486pXBgPeoUra1AVWnEtLEqUQucgtVeaGSmsynUtpmR-yI2uwbavPvpN6NLC6mVPpfqDTAIIlifD5cHgQh9jQF8NIX0ZdhWDas-6-m_8ZS2-AJeWbqc</recordid><startdate>201712</startdate><enddate>201712</enddate><creator>GONZAGA, Amanda Katarinny Goes</creator><creator>PEIXOTO, Larissa Rangel</creator><creator>OLIVEIRA, Luciana Soares de Andrade Freitas</creator><creator>MELO, Saulo Leonardo Sousa</creator><creator>CAMPOS, Paulo Sérgio Flores</creator><creator>MELO, Daniela Pita de</creator><general>Faculdade São Leopoldo Mandic</general><scope>AAYXX</scope><scope>CITATION</scope><scope>GPN</scope></search><sort><creationdate>201712</creationdate><title>The effect of different exposure parameters on proximal caries detection using the Kodak 9000 3D CBCT system</title><author>GONZAGA, Amanda Katarinny Goes ; PEIXOTO, Larissa Rangel ; OLIVEIRA, Luciana Soares de Andrade Freitas ; MELO, Saulo Leonardo Sousa ; CAMPOS, Paulo Sérgio Flores ; MELO, Daniela Pita de</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1426-ee4dc2f1339a7fe74c2cc6539f08beba9e6786283ae4e4385048f681943a658d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; por</language><creationdate>2017</creationdate><topic>DENTISTRY, ORAL SURGERY &amp; MEDICINE</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>GONZAGA, Amanda Katarinny Goes</creatorcontrib><creatorcontrib>PEIXOTO, Larissa Rangel</creatorcontrib><creatorcontrib>OLIVEIRA, Luciana Soares de Andrade Freitas</creatorcontrib><creatorcontrib>MELO, Saulo Leonardo Sousa</creatorcontrib><creatorcontrib>CAMPOS, Paulo Sérgio Flores</creatorcontrib><creatorcontrib>MELO, Daniela Pita de</creatorcontrib><collection>CrossRef</collection><collection>SciELO</collection><jtitle>RGO - Revista Gaúcha de Odontologia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>GONZAGA, Amanda Katarinny Goes</au><au>PEIXOTO, Larissa Rangel</au><au>OLIVEIRA, Luciana Soares de Andrade Freitas</au><au>MELO, Saulo Leonardo Sousa</au><au>CAMPOS, Paulo Sérgio Flores</au><au>MELO, Daniela Pita de</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The effect of different exposure parameters on proximal caries detection using the Kodak 9000 3D CBCT system</atitle><jtitle>RGO - Revista Gaúcha de Odontologia</jtitle><addtitle>RGO, Rev. Gaúch. Odontol</addtitle><date>2017-12</date><risdate>2017</risdate><volume>65</volume><issue>4</issue><spage>315</spage><epage>320</epage><pages>315-320</pages><issn>0103-6971</issn><issn>1981-8637</issn><eissn>1981-8637</eissn><abstract>ABSTRACT Objective: The objective of study was to evaluate the diagnostic quality of CBCT images for caries lesions detection using different exposure parameters. Methods: Sixty extracted human teeth were selected and scanned using Kodak 9000 3D CBCT system, with the following exposure parameters combinations: 74 kV, 10mA; 74 kV, 12mA; 74 kV, 8 mA; 70 kV, 10 mA; 70kV, 12 mA; 70 kV e 8 mA; 70 kV, 6.3 mA. Two observers evaluated the images for caries presence using CS 3D Imaging Software. Each observer scored the proximal surfaces of each tooth on a 5-point scale. The scores were compared to histological sections used as gold standard. Accuracy for caries lesion detection was assessed for each exposure parameter combination and evaluated by means of ROC curve analysis. Results: The mean values for the areas under the ROC curves for each exposure parameter combination varied from 0.35 to 0.60. There was no statistical significant difference among protocols 1, 2, 4, 6 and 7. However, protocols 3 and 5 differed from all protocols. Conclusion: Although the highest dose protocol was the most efficient for proximal caries detection, the lowest dose protocol should be chosen based on the ALADA principle. RESUMO Objetivo: Avaliar a qualidade de diagnóstico de imagens de TCFC para detecção de lesões de cárie utilizando parâmetros de exposição diferentes. Métodos: Sessenta dentes humanos extraídos foram selecionados e digitalizados usando o sistema Kodak 9000 3D TCFC, com as seguintes combinações de parâmetros de exposição: 74 kV, 10 mA; 74 kV, 12 mA; 74 kV, 8 mA70 kV, 10 mA; 70 kV, 12 mA; 70 kV e 8 mA; 70 kV, 6,3 mA. Dois observadores avaliaram as imagens para a presença de cárie utilizando o CS 3D Imaging Software. Cada observador pontuou as superfícies proximais de cada dente em uma escala de 5 pontos. Os escores foram comparados com cortes histológicos, utilizados como padrão-ouro. A precisão para detecção de lesões de cárie foi analisada para cada combinação de parâmetros de exposição e avaliada por meio de análise da curva ROC. Resultados: Os valores médios para as áreas sob as curvas ROC para cada combinação de parâmetro de exposição variou de 0,35-0,60. Não houve diferença estatística significativa entre os protocolos 1, 2, 4, 6 e 7. No entanto, os protocolos 3 e 5 diferem de todos os protocolos. Conclusão: Embora o protocolo de dose mais elevada foi o mais eficiente para a detecção da cárie proximal, o protocolo de dose mais baixa deverá ser escolhido com base no princípio ALADA.</abstract><pub>Faculdade São Leopoldo Mandic</pub><doi>10.1590/1981-863720170002000053256</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0103-6971
ispartof RGO - Revista Gaúcha de Odontologia, 2017-12, Vol.65 (4), p.315-320
issn 0103-6971
1981-8637
1981-8637
language eng ; por
recordid cdi_scielo_journals_S1981_86372017000400315
source SciELO Brazil
subjects DENTISTRY, ORAL SURGERY & MEDICINE
title The effect of different exposure parameters on proximal caries detection using the Kodak 9000 3D CBCT system
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-23T23%3A20%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scielo_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20effect%20of%20different%20exposure%20parameters%20on%20proximal%20caries%20detection%20using%20the%20Kodak%209000%203D%20CBCT%20system&rft.jtitle=RGO%20-%20Revista%20Ga%C3%BAcha%20de%20Odontologia&rft.au=GONZAGA,%20Amanda%20Katarinny%20Goes&rft.date=2017-12&rft.volume=65&rft.issue=4&rft.spage=315&rft.epage=320&rft.pages=315-320&rft.issn=0103-6971&rft.eissn=1981-8637&rft_id=info:doi/10.1590/1981-863720170002000053256&rft_dat=%3Cscielo_cross%3ES1981_86372017000400315%3C/scielo_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c1426-ee4dc2f1339a7fe74c2cc6539f08beba9e6786283ae4e4385048f681943a658d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_scielo_id=S1981_86372017000400315&rfr_iscdi=true