Magnetic measurements on insertion devices at NSLS
Magnetic measurements on three insertion devices for use in the National Synchrotron Light Source (NSLS) x‐ray ring are described. Hall probes were used for field mapping, and rotating long coils were used to determine integrated multipole coefficients. Results are presented for an iron pole‐REC hyb...
Saved in:
Published in: | Review of Scientific Instruments 1989-07, Vol.60 (7), p.1845-1848 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Magnetic measurements on three insertion devices for use in the National Synchrotron Light Source (NSLS) x‐ray ring are described. Hall probes were used for field mapping, and rotating long coils were used to determine integrated multipole coefficients. Results are presented for an iron pole‐REC hybrid indulator, a vanadium permendur pole‐REC hybrid wiggler, and a 5 T superconducting wiggler. |
---|---|
ISSN: | 0034-6748 1089-7623 |
DOI: | 10.1063/1.1140919 |