Magnetic measurements on insertion devices at NSLS

Magnetic measurements on three insertion devices for use in the National Synchrotron Light Source (NSLS) x‐ray ring are described. Hall probes were used for field mapping, and rotating long coils were used to determine integrated multipole coefficients. Results are presented for an iron pole‐REC hyb...

Full description

Saved in:
Bibliographic Details
Published in:Review of Scientific Instruments 1989-07, Vol.60 (7), p.1845-1848
Main Authors: Decker, Glenn, Galayda, John, Solomon, L., Kitamura, M.
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Magnetic measurements on three insertion devices for use in the National Synchrotron Light Source (NSLS) x‐ray ring are described. Hall probes were used for field mapping, and rotating long coils were used to determine integrated multipole coefficients. Results are presented for an iron pole‐REC hybrid indulator, a vanadium permendur pole‐REC hybrid wiggler, and a 5 T superconducting wiggler.