Loading…
Simple fabricating PCB-based inter digital capacitor for glucose biosensor
This paper presents the simple fabrication of interdigital capacitor (IDC) using print circuit board (PCB) for glucose biosensor. PCB type FR04 laminated with Cu as electrode was used as sensor base. The IDC pattern of sensor was designed by computer aided design program and printed with a laser pri...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | |
container_issue | 1 |
container_start_page | |
container_title | |
container_volume | 1788 |
creator | Jamaluddin, Anif Taufik, Usman Iriani, Yofentina Budiawanti, Sri Suyitno |
description | This paper presents the simple fabrication of interdigital capacitor (IDC) using print circuit board (PCB) for glucose biosensor. PCB type FR04 laminated with Cu as electrode was used as sensor base. The IDC pattern of sensor was designed by computer aided design program and printed with a laser printer on plastic polymers. Then, the IDC pattern was transferred into PCB by a laminating machine. The etching process of PCB was done by immersing in ferric chloride liquid to form Cu pattern. There were five patterns of sensors including 5, 10, 15, 20 and 25 patterns. The capacitance value of PCB was measured with RCL meter when IDC biosensor was put in air, aquades, and glucose liquid with various moles of glucose (0.02, 0.04, 0.06, 0.08, 0.1M). In air medium, the increase of pattern number of IDC sensor (from 5 to 25) caused the sensor capacitance rose from 22 pf to 46 pf. In addition, the capacitance of sensor was dramatically increased until 0.36 µf while IDC sensor with 25 patterns was put in aquades medium. In liquid glucose medium, the capacitance of IDC biosensor with 25 patterns increased until 0.58 µf on 0.1 M glucose liquid. |
doi_str_mv | 10.1063/1.4968345 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_scitation_primary_10_1063_1_4968345</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2124692648</sourcerecordid><originalsourceid>FETCH-LOGICAL-p253t-755b1a45e3fd0e556cba3b24deb898c6c0a3c502ce06ec59a894b4b9e042dd333</originalsourceid><addsrcrecordid>eNp9kEtLxDAUhYMoWEcX_oOAO6Fj3m2WWnwyoKCCu5BXS4ZOU5OO4L-3MgPuXNxzNx_n3nMAOMdoiZGgV3jJpKgp4wegwJzjshJYHIICIclKwujHMTjJeY0QkVVVF-DpNWzG3sNWmxSsnsLQwZfmpjQ6ewfDMPkEXejCpHto9ahtmGKC7Txdv7Uxe2jCrEOO6RQctbrP_my_F-D97vateShXz_ePzfWqHAmnU1lxbrBm3NPWIc-5sEZTQ5jzppa1FRZpajki1iPhLZe6lswwIz1ixDlK6QJc7HzHFD-3Pk9qHbdpmE8qggkTkghWz9Tljsrzy3OuOKgxhY1O3woj9duVwmrf1X_wV0x_oBpdS38AYVJqYw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>2124692648</pqid></control><display><type>conference_proceeding</type><title>Simple fabricating PCB-based inter digital capacitor for glucose biosensor</title><source>American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)</source><creator>Jamaluddin, Anif ; Taufik, Usman ; Iriani, Yofentina ; Budiawanti, Sri ; Suyitno</creator><contributor>Wijayanta, Agung Tri ; Suyitno ; Triyono, Joko ; Danardono, Dominicus ; Ariawan, Dody ; Surojo, Eko ; Anwar, Miftahul ; Hadi, Syamsul ; Triyono ; Ubaidillah ; Santoso, Budi ; Muhayat, Nurul ; Kristiawan, Budi</contributor><creatorcontrib>Jamaluddin, Anif ; Taufik, Usman ; Iriani, Yofentina ; Budiawanti, Sri ; Suyitno ; Wijayanta, Agung Tri ; Suyitno ; Triyono, Joko ; Danardono, Dominicus ; Ariawan, Dody ; Surojo, Eko ; Anwar, Miftahul ; Hadi, Syamsul ; Triyono ; Ubaidillah ; Santoso, Budi ; Muhayat, Nurul ; Kristiawan, Budi</creatorcontrib><description>This paper presents the simple fabrication of interdigital capacitor (IDC) using print circuit board (PCB) for glucose biosensor. PCB type FR04 laminated with Cu as electrode was used as sensor base. The IDC pattern of sensor was designed by computer aided design program and printed with a laser printer on plastic polymers. Then, the IDC pattern was transferred into PCB by a laminating machine. The etching process of PCB was done by immersing in ferric chloride liquid to form Cu pattern. There were five patterns of sensors including 5, 10, 15, 20 and 25 patterns. The capacitance value of PCB was measured with RCL meter when IDC biosensor was put in air, aquades, and glucose liquid with various moles of glucose (0.02, 0.04, 0.06, 0.08, 0.1M). In air medium, the increase of pattern number of IDC sensor (from 5 to 25) caused the sensor capacitance rose from 22 pf to 46 pf. In addition, the capacitance of sensor was dramatically increased until 0.36 µf while IDC sensor with 25 patterns was put in aquades medium. In liquid glucose medium, the capacitance of IDC biosensor with 25 patterns increased until 0.58 µf on 0.1 M glucose liquid.</description><identifier>ISSN: 0094-243X</identifier><identifier>EISSN: 1551-7616</identifier><identifier>DOI: 10.1063/1.4968345</identifier><identifier>CODEN: APCPCS</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Biosensors ; CAD ; Capacitance ; Capacitors ; Circuit boards ; Computer aided design ; Ferric chloride ; Glucose ; Iron chlorides ; Laminating ; Printed circuits ; Sensors</subject><ispartof>AIP conference proceedings, 2017, Vol.1788 (1)</ispartof><rights>Author(s)</rights><rights>2016 Author(s). Published by AIP Publishing.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,776,780,785,786,23909,23910,25118,27901,27902</link.rule.ids></links><search><contributor>Wijayanta, Agung Tri</contributor><contributor>Suyitno</contributor><contributor>Triyono, Joko</contributor><contributor>Danardono, Dominicus</contributor><contributor>Ariawan, Dody</contributor><contributor>Surojo, Eko</contributor><contributor>Anwar, Miftahul</contributor><contributor>Hadi, Syamsul</contributor><contributor>Triyono</contributor><contributor>Ubaidillah</contributor><contributor>Santoso, Budi</contributor><contributor>Muhayat, Nurul</contributor><contributor>Kristiawan, Budi</contributor><creatorcontrib>Jamaluddin, Anif</creatorcontrib><creatorcontrib>Taufik, Usman</creatorcontrib><creatorcontrib>Iriani, Yofentina</creatorcontrib><creatorcontrib>Budiawanti, Sri</creatorcontrib><creatorcontrib>Suyitno</creatorcontrib><title>Simple fabricating PCB-based inter digital capacitor for glucose biosensor</title><title>AIP conference proceedings</title><description>This paper presents the simple fabrication of interdigital capacitor (IDC) using print circuit board (PCB) for glucose biosensor. PCB type FR04 laminated with Cu as electrode was used as sensor base. The IDC pattern of sensor was designed by computer aided design program and printed with a laser printer on plastic polymers. Then, the IDC pattern was transferred into PCB by a laminating machine. The etching process of PCB was done by immersing in ferric chloride liquid to form Cu pattern. There were five patterns of sensors including 5, 10, 15, 20 and 25 patterns. The capacitance value of PCB was measured with RCL meter when IDC biosensor was put in air, aquades, and glucose liquid with various moles of glucose (0.02, 0.04, 0.06, 0.08, 0.1M). In air medium, the increase of pattern number of IDC sensor (from 5 to 25) caused the sensor capacitance rose from 22 pf to 46 pf. In addition, the capacitance of sensor was dramatically increased until 0.36 µf while IDC sensor with 25 patterns was put in aquades medium. In liquid glucose medium, the capacitance of IDC biosensor with 25 patterns increased until 0.58 µf on 0.1 M glucose liquid.</description><subject>Biosensors</subject><subject>CAD</subject><subject>Capacitance</subject><subject>Capacitors</subject><subject>Circuit boards</subject><subject>Computer aided design</subject><subject>Ferric chloride</subject><subject>Glucose</subject><subject>Iron chlorides</subject><subject>Laminating</subject><subject>Printed circuits</subject><subject>Sensors</subject><issn>0094-243X</issn><issn>1551-7616</issn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2017</creationdate><recordtype>conference_proceeding</recordtype><sourceid>AJDQP</sourceid><recordid>eNp9kEtLxDAUhYMoWEcX_oOAO6Fj3m2WWnwyoKCCu5BXS4ZOU5OO4L-3MgPuXNxzNx_n3nMAOMdoiZGgV3jJpKgp4wegwJzjshJYHIICIclKwujHMTjJeY0QkVVVF-DpNWzG3sNWmxSsnsLQwZfmpjQ6ewfDMPkEXejCpHto9ahtmGKC7Txdv7Uxe2jCrEOO6RQctbrP_my_F-D97vateShXz_ePzfWqHAmnU1lxbrBm3NPWIc-5sEZTQ5jzppa1FRZpajki1iPhLZe6lswwIz1ixDlK6QJc7HzHFD-3Pk9qHbdpmE8qggkTkghWz9Tljsrzy3OuOKgxhY1O3woj9duVwmrf1X_wV0x_oBpdS38AYVJqYw</recordid><startdate>20170103</startdate><enddate>20170103</enddate><creator>Jamaluddin, Anif</creator><creator>Taufik, Usman</creator><creator>Iriani, Yofentina</creator><creator>Budiawanti, Sri</creator><creator>Suyitno</creator><general>American Institute of Physics</general><scope>AJDQP</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20170103</creationdate><title>Simple fabricating PCB-based inter digital capacitor for glucose biosensor</title><author>Jamaluddin, Anif ; Taufik, Usman ; Iriani, Yofentina ; Budiawanti, Sri ; Suyitno</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p253t-755b1a45e3fd0e556cba3b24deb898c6c0a3c502ce06ec59a894b4b9e042dd333</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Biosensors</topic><topic>CAD</topic><topic>Capacitance</topic><topic>Capacitors</topic><topic>Circuit boards</topic><topic>Computer aided design</topic><topic>Ferric chloride</topic><topic>Glucose</topic><topic>Iron chlorides</topic><topic>Laminating</topic><topic>Printed circuits</topic><topic>Sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jamaluddin, Anif</creatorcontrib><creatorcontrib>Taufik, Usman</creatorcontrib><creatorcontrib>Iriani, Yofentina</creatorcontrib><creatorcontrib>Budiawanti, Sri</creatorcontrib><creatorcontrib>Suyitno</creatorcontrib><collection>AIP Open Access Journals</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jamaluddin, Anif</au><au>Taufik, Usman</au><au>Iriani, Yofentina</au><au>Budiawanti, Sri</au><au>Suyitno</au><au>Wijayanta, Agung Tri</au><au>Suyitno</au><au>Triyono, Joko</au><au>Danardono, Dominicus</au><au>Ariawan, Dody</au><au>Surojo, Eko</au><au>Anwar, Miftahul</au><au>Hadi, Syamsul</au><au>Triyono</au><au>Ubaidillah</au><au>Santoso, Budi</au><au>Muhayat, Nurul</au><au>Kristiawan, Budi</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Simple fabricating PCB-based inter digital capacitor for glucose biosensor</atitle><btitle>AIP conference proceedings</btitle><date>2017-01-03</date><risdate>2017</risdate><volume>1788</volume><issue>1</issue><issn>0094-243X</issn><eissn>1551-7616</eissn><coden>APCPCS</coden><abstract>This paper presents the simple fabrication of interdigital capacitor (IDC) using print circuit board (PCB) for glucose biosensor. PCB type FR04 laminated with Cu as electrode was used as sensor base. The IDC pattern of sensor was designed by computer aided design program and printed with a laser printer on plastic polymers. Then, the IDC pattern was transferred into PCB by a laminating machine. The etching process of PCB was done by immersing in ferric chloride liquid to form Cu pattern. There were five patterns of sensors including 5, 10, 15, 20 and 25 patterns. The capacitance value of PCB was measured with RCL meter when IDC biosensor was put in air, aquades, and glucose liquid with various moles of glucose (0.02, 0.04, 0.06, 0.08, 0.1M). In air medium, the increase of pattern number of IDC sensor (from 5 to 25) caused the sensor capacitance rose from 22 pf to 46 pf. In addition, the capacitance of sensor was dramatically increased until 0.36 µf while IDC sensor with 25 patterns was put in aquades medium. In liquid glucose medium, the capacitance of IDC biosensor with 25 patterns increased until 0.58 µf on 0.1 M glucose liquid.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/1.4968345</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0094-243X |
ispartof | AIP conference proceedings, 2017, Vol.1788 (1) |
issn | 0094-243X 1551-7616 |
language | eng |
recordid | cdi_scitation_primary_10_1063_1_4968345 |
source | American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list) |
subjects | Biosensors CAD Capacitance Capacitors Circuit boards Computer aided design Ferric chloride Glucose Iron chlorides Laminating Printed circuits Sensors |
title | Simple fabricating PCB-based inter digital capacitor for glucose biosensor |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T13%3A07%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Simple%20fabricating%20PCB-based%20inter%20digital%20capacitor%20for%20glucose%20biosensor&rft.btitle=AIP%20conference%20proceedings&rft.au=Jamaluddin,%20Anif&rft.date=2017-01-03&rft.volume=1788&rft.issue=1&rft.issn=0094-243X&rft.eissn=1551-7616&rft.coden=APCPCS&rft_id=info:doi/10.1063/1.4968345&rft_dat=%3Cproquest_scita%3E2124692648%3C/proquest_scita%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-p253t-755b1a45e3fd0e556cba3b24deb898c6c0a3c502ce06ec59a894b4b9e042dd333%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2124692648&rft_id=info:pmid/&rfr_iscdi=true |