Loading…

Optimal measurement counting time and statistics in gamma spectrometry analysis: The time balance

The optimal measurement counting time for gamma-ray spectrometry analysis using HPGe detectors was determined in our laboratory by comparing twelve hours measurement counting time at day and twelve hours measurement counting time at night. The day spectrum does not fully cover the night spectrum for...

Full description

Saved in:
Bibliographic Details
Main Authors: Joel, Guembou Shouop Cebastien, Penabei, Samafou, Maurice, Ndontchueng Moyo, Gregoire, Chene, Jilbert, Nguelem Mekontso Eric, Didier, Takoukam Serge, David, Strivay
Format: Conference Proceeding
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c372t-f637ea3173fa18cf02f0f24aa42639d885f48ef0fece7bc97d95e7f7752d4ad63
cites
container_end_page
container_issue 1
container_start_page
container_title
container_volume 1792
creator Joel, Guembou Shouop Cebastien
Penabei, Samafou
Maurice, Ndontchueng Moyo
Gregoire, Chene
Jilbert, Nguelem Mekontso Eric
Didier, Takoukam Serge
David, Strivay
description The optimal measurement counting time for gamma-ray spectrometry analysis using HPGe detectors was determined in our laboratory by comparing twelve hours measurement counting time at day and twelve hours measurement counting time at night. The day spectrum does not fully cover the night spectrum for the same sample. It is observed that the perturbation come to the sun-light. After several investigations became clearer: to remove all effects of radiation from outside (earth, the sun, and universe) our system, it is necessary to measure the background for 24, 48 or 72 hours. In the same way, the samples have to be measured for 24, 48 or 72 hours to be safe to be purified the measurement (equality of day and night measurement). It is also possible to not use the background of the winter in summer. Depend on to the energy of radionuclide we seek, it is clear that the most important steps of a gamma spectrometry measurement are the preparation of the sample and the calibration of the detector. At the request of all authors of the paper, and with the agreement of the Proceedings Editor, an updated version of this article was published on 23 June 2017. The original version supplied to AIP Publishing included the name of an author who was not consulted and has asked for his name to be removed. This has been corrected in the updated and re-published version.
doi_str_mv 10.1063/1.4969040
format conference_proceeding
fullrecord <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_scitation_primary_10_1063_1_4969040</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2116072550</sourcerecordid><originalsourceid>FETCH-LOGICAL-c372t-f637ea3173fa18cf02f0f24aa42639d885f48ef0fece7bc97d95e7f7752d4ad63</originalsourceid><addsrcrecordid>eNp9kE1LAzEQhoMoWKsH_0HAm7A1X5vsepPiFxR6qeAtTLOTuqX7YZIV-u_d0oI3TwMzzzvMPITccjbjTMsHPlOlLpliZ2TC85xnRnN9TiaMlSoTSn5ekqsYt4yJ0phiQmDZp7qBHW0Q4hCwwTZR1w1tqtsNHUdIoa1oTJDqmGoXad3SDTQN0NijS6FrMIX9CMFuH-v4SFdfeMytYQetw2ty4WEX8eZUp-Tj5Xk1f8sWy9f3-dMic9KIlHktDYLkRnrghfNMeOaFAlBCy7IqityrAsceOjRrV5qqzNF4Y3JRKai0nJK7494-dN8DxmS33RDGs6IVnGtmRJ6zkbo_UtHVh5-61vZhFBD29qcLltuTPttX_j-YM3vw_ReQvxSPc5w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>2116072550</pqid></control><display><type>conference_proceeding</type><title>Optimal measurement counting time and statistics in gamma spectrometry analysis: The time balance</title><source>American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)</source><creator>Joel, Guembou Shouop Cebastien ; Penabei, Samafou ; Maurice, Ndontchueng Moyo ; Gregoire, Chene ; Jilbert, Nguelem Mekontso Eric ; Didier, Takoukam Serge ; David, Strivay</creator><contributor>Aharonian, Felix A. ; Rieger, Frank M. ; Hofmann, Werner</contributor><creatorcontrib>Joel, Guembou Shouop Cebastien ; Penabei, Samafou ; Maurice, Ndontchueng Moyo ; Gregoire, Chene ; Jilbert, Nguelem Mekontso Eric ; Didier, Takoukam Serge ; David, Strivay ; Aharonian, Felix A. ; Rieger, Frank M. ; Hofmann, Werner</creatorcontrib><description>The optimal measurement counting time for gamma-ray spectrometry analysis using HPGe detectors was determined in our laboratory by comparing twelve hours measurement counting time at day and twelve hours measurement counting time at night. The day spectrum does not fully cover the night spectrum for the same sample. It is observed that the perturbation come to the sun-light. After several investigations became clearer: to remove all effects of radiation from outside (earth, the sun, and universe) our system, it is necessary to measure the background for 24, 48 or 72 hours. In the same way, the samples have to be measured for 24, 48 or 72 hours to be safe to be purified the measurement (equality of day and night measurement). It is also possible to not use the background of the winter in summer. Depend on to the energy of radionuclide we seek, it is clear that the most important steps of a gamma spectrometry measurement are the preparation of the sample and the calibration of the detector. At the request of all authors of the paper, and with the agreement of the Proceedings Editor, an updated version of this article was published on 23 June 2017. The original version supplied to AIP Publishing included the name of an author who was not consulted and has asked for his name to be removed. This has been corrected in the updated and re-published version.</description><identifier>ISSN: 0094-243X</identifier><identifier>EISSN: 1551-7616</identifier><identifier>DOI: 10.1063/1.4969040</identifier><identifier>CODEN: APCPCS</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Gamma rays ; Night ; Radioisotopes ; Scientific imaging ; Time measurement ; Universe</subject><ispartof>AIP conference proceedings, 2017, Vol.1792 (1)</ispartof><rights>Author(s)</rights><rights>2017 Author(s). Published by AIP Publishing.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c372t-f637ea3173fa18cf02f0f24aa42639d885f48ef0fece7bc97d95e7f7752d4ad63</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,780,784,789,790,23930,23931,25140,27924,27925</link.rule.ids></links><search><contributor>Aharonian, Felix A.</contributor><contributor>Rieger, Frank M.</contributor><contributor>Hofmann, Werner</contributor><creatorcontrib>Joel, Guembou Shouop Cebastien</creatorcontrib><creatorcontrib>Penabei, Samafou</creatorcontrib><creatorcontrib>Maurice, Ndontchueng Moyo</creatorcontrib><creatorcontrib>Gregoire, Chene</creatorcontrib><creatorcontrib>Jilbert, Nguelem Mekontso Eric</creatorcontrib><creatorcontrib>Didier, Takoukam Serge</creatorcontrib><creatorcontrib>David, Strivay</creatorcontrib><title>Optimal measurement counting time and statistics in gamma spectrometry analysis: The time balance</title><title>AIP conference proceedings</title><description>The optimal measurement counting time for gamma-ray spectrometry analysis using HPGe detectors was determined in our laboratory by comparing twelve hours measurement counting time at day and twelve hours measurement counting time at night. The day spectrum does not fully cover the night spectrum for the same sample. It is observed that the perturbation come to the sun-light. After several investigations became clearer: to remove all effects of radiation from outside (earth, the sun, and universe) our system, it is necessary to measure the background for 24, 48 or 72 hours. In the same way, the samples have to be measured for 24, 48 or 72 hours to be safe to be purified the measurement (equality of day and night measurement). It is also possible to not use the background of the winter in summer. Depend on to the energy of radionuclide we seek, it is clear that the most important steps of a gamma spectrometry measurement are the preparation of the sample and the calibration of the detector. At the request of all authors of the paper, and with the agreement of the Proceedings Editor, an updated version of this article was published on 23 June 2017. The original version supplied to AIP Publishing included the name of an author who was not consulted and has asked for his name to be removed. This has been corrected in the updated and re-published version.</description><subject>Gamma rays</subject><subject>Night</subject><subject>Radioisotopes</subject><subject>Scientific imaging</subject><subject>Time measurement</subject><subject>Universe</subject><issn>0094-243X</issn><issn>1551-7616</issn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2017</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNp9kE1LAzEQhoMoWKsH_0HAm7A1X5vsepPiFxR6qeAtTLOTuqX7YZIV-u_d0oI3TwMzzzvMPITccjbjTMsHPlOlLpliZ2TC85xnRnN9TiaMlSoTSn5ekqsYt4yJ0phiQmDZp7qBHW0Q4hCwwTZR1w1tqtsNHUdIoa1oTJDqmGoXad3SDTQN0NijS6FrMIX9CMFuH-v4SFdfeMytYQetw2ty4WEX8eZUp-Tj5Xk1f8sWy9f3-dMic9KIlHktDYLkRnrghfNMeOaFAlBCy7IqityrAsceOjRrV5qqzNF4Y3JRKai0nJK7494-dN8DxmS33RDGs6IVnGtmRJ6zkbo_UtHVh5-61vZhFBD29qcLltuTPttX_j-YM3vw_ReQvxSPc5w</recordid><startdate>20170104</startdate><enddate>20170104</enddate><creator>Joel, Guembou Shouop Cebastien</creator><creator>Penabei, Samafou</creator><creator>Maurice, Ndontchueng Moyo</creator><creator>Gregoire, Chene</creator><creator>Jilbert, Nguelem Mekontso Eric</creator><creator>Didier, Takoukam Serge</creator><creator>David, Strivay</creator><general>American Institute of Physics</general><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20170104</creationdate><title>Optimal measurement counting time and statistics in gamma spectrometry analysis: The time balance</title><author>Joel, Guembou Shouop Cebastien ; Penabei, Samafou ; Maurice, Ndontchueng Moyo ; Gregoire, Chene ; Jilbert, Nguelem Mekontso Eric ; Didier, Takoukam Serge ; David, Strivay</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c372t-f637ea3173fa18cf02f0f24aa42639d885f48ef0fece7bc97d95e7f7752d4ad63</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Gamma rays</topic><topic>Night</topic><topic>Radioisotopes</topic><topic>Scientific imaging</topic><topic>Time measurement</topic><topic>Universe</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Joel, Guembou Shouop Cebastien</creatorcontrib><creatorcontrib>Penabei, Samafou</creatorcontrib><creatorcontrib>Maurice, Ndontchueng Moyo</creatorcontrib><creatorcontrib>Gregoire, Chene</creatorcontrib><creatorcontrib>Jilbert, Nguelem Mekontso Eric</creatorcontrib><creatorcontrib>Didier, Takoukam Serge</creatorcontrib><creatorcontrib>David, Strivay</creatorcontrib><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Joel, Guembou Shouop Cebastien</au><au>Penabei, Samafou</au><au>Maurice, Ndontchueng Moyo</au><au>Gregoire, Chene</au><au>Jilbert, Nguelem Mekontso Eric</au><au>Didier, Takoukam Serge</au><au>David, Strivay</au><au>Aharonian, Felix A.</au><au>Rieger, Frank M.</au><au>Hofmann, Werner</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Optimal measurement counting time and statistics in gamma spectrometry analysis: The time balance</atitle><btitle>AIP conference proceedings</btitle><date>2017-01-04</date><risdate>2017</risdate><volume>1792</volume><issue>1</issue><issn>0094-243X</issn><eissn>1551-7616</eissn><coden>APCPCS</coden><abstract>The optimal measurement counting time for gamma-ray spectrometry analysis using HPGe detectors was determined in our laboratory by comparing twelve hours measurement counting time at day and twelve hours measurement counting time at night. The day spectrum does not fully cover the night spectrum for the same sample. It is observed that the perturbation come to the sun-light. After several investigations became clearer: to remove all effects of radiation from outside (earth, the sun, and universe) our system, it is necessary to measure the background for 24, 48 or 72 hours. In the same way, the samples have to be measured for 24, 48 or 72 hours to be safe to be purified the measurement (equality of day and night measurement). It is also possible to not use the background of the winter in summer. Depend on to the energy of radionuclide we seek, it is clear that the most important steps of a gamma spectrometry measurement are the preparation of the sample and the calibration of the detector. At the request of all authors of the paper, and with the agreement of the Proceedings Editor, an updated version of this article was published on 23 June 2017. The original version supplied to AIP Publishing included the name of an author who was not consulted and has asked for his name to be removed. This has been corrected in the updated and re-published version.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/1.4969040</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0094-243X
ispartof AIP conference proceedings, 2017, Vol.1792 (1)
issn 0094-243X
1551-7616
language eng
recordid cdi_scitation_primary_10_1063_1_4969040
source American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)
subjects Gamma rays
Night
Radioisotopes
Scientific imaging
Time measurement
Universe
title Optimal measurement counting time and statistics in gamma spectrometry analysis: The time balance
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T00%3A27%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Optimal%20measurement%20counting%20time%20and%20statistics%20in%20gamma%20spectrometry%20analysis:%20The%20time%20balance&rft.btitle=AIP%20conference%20proceedings&rft.au=Joel,%20Guembou%20Shouop%20Cebastien&rft.date=2017-01-04&rft.volume=1792&rft.issue=1&rft.issn=0094-243X&rft.eissn=1551-7616&rft.coden=APCPCS&rft_id=info:doi/10.1063/1.4969040&rft_dat=%3Cproquest_scita%3E2116072550%3C/proquest_scita%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c372t-f637ea3173fa18cf02f0f24aa42639d885f48ef0fece7bc97d95e7f7752d4ad63%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2116072550&rft_id=info:pmid/&rfr_iscdi=true