Loading…
Demonstrating H− beam focusing using an elliptical einzel lens
H− ion source research is being performed at the ISIS spallation neutron and muon facility on a dedicated Vessel for Extraction and Source Plasma Analyses (VESPA). The ion extraction and optics system presently being used on ISIS is centered on a combined-function sector dipole magnet. This traps ce...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | |
container_issue | 1 |
container_start_page | |
container_title | |
container_volume | 1869 |
creator | Lawrie, S. R. Faircloth, D. C. Letchford, A. P. Whitehead, M. O. Wood, T. |
description | H− ion source research is being performed at the ISIS spallation neutron and muon facility on a dedicated Vessel for Extraction and Source Plasma Analyses (VESPA). The ion extraction and optics system presently being used on ISIS is centered on a combined-function sector dipole magnet. This traps cesium vapor escaping the ion source; mass-separates co-extracted electrons and stripped neutrals, and weak-focusses the highly asymmetric slit-shaped ion beam. Unfortunately the added drift length through the magnet under strong space-charge forces means up to 50% of the beam is collimated on the magnet. The VESPA has shown that the ISIS ion source actually produces 80 mA of beam current at standard settings, but because of magnet collimation only 55 mA is injected into the solenoid Low Energy Beam Transport (LEBT). A new purely electrostatic post-extraction system incorporating an einzel lens with an elliptical aperture is currently under test. This allows much greater flexibility of perveance and phase space matching for injection into the LEBT and Radio Frequency Quadrupole (RFQ). This paper discusses high voltage breakdown mitigation strategies and presents the first results of the novel elliptical transport system. So far, 70 mA of beam has been transported through the new system with a normalized transverse RMS emittance of 0.2 π mm mrad. |
doi_str_mv | 10.1063/1.4995782 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_scitation_primary_10_1063_1_4995782</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2116072243</sourcerecordid><originalsourceid>FETCH-LOGICAL-p288t-2191fa19f7c10b70b6ac03c5332a7e0764b297a602ea2072a142b0c7cad12ec13</originalsourceid><addsrcrecordid>eNp9kMFKxDAQhoMoWFcPvkHBm9B1JmmT9qasqysseFHwFqbZVLq0aW1aQZ_As4_ok9ilC968zMDw_TPz_4ydI8wRpLjCeZxliUr5AQswSTBSEuUhCwCyOOKxeDlmJ95vAXimVBqw61tbN873HfWlew1XP1_fYW6pDovGDH43miq50FZV2faloSq0pfu0VVhZ50_ZUUGVt2f7PmPPd8unxSpaP94_LG7WUcvTtI84ZlgQZoUyCLmCXJIBYRIhOCkLSsb5-BFJ4JY4KE4Y8xyMMrRBbg2KGbuY9rZd8zZY3-ttM3RuPKk5ohwlo7uRupwob8p-tNQ43XZlTd2Hfm86jXqfjm43xX8wgt7F-ScQv1BBZrI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>2116072243</pqid></control><display><type>conference_proceeding</type><title>Demonstrating H− beam focusing using an elliptical einzel lens</title><source>American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)</source><creator>Lawrie, S. R. ; Faircloth, D. C. ; Letchford, A. P. ; Whitehead, M. O. ; Wood, T.</creator><contributor>Faircloth, Dan</contributor><creatorcontrib>Lawrie, S. R. ; Faircloth, D. C. ; Letchford, A. P. ; Whitehead, M. O. ; Wood, T. ; Faircloth, Dan</creatorcontrib><description>H− ion source research is being performed at the ISIS spallation neutron and muon facility on a dedicated Vessel for Extraction and Source Plasma Analyses (VESPA). The ion extraction and optics system presently being used on ISIS is centered on a combined-function sector dipole magnet. This traps cesium vapor escaping the ion source; mass-separates co-extracted electrons and stripped neutrals, and weak-focusses the highly asymmetric slit-shaped ion beam. Unfortunately the added drift length through the magnet under strong space-charge forces means up to 50% of the beam is collimated on the magnet. The VESPA has shown that the ISIS ion source actually produces 80 mA of beam current at standard settings, but because of magnet collimation only 55 mA is injected into the solenoid Low Energy Beam Transport (LEBT). A new purely electrostatic post-extraction system incorporating an einzel lens with an elliptical aperture is currently under test. This allows much greater flexibility of perveance and phase space matching for injection into the LEBT and Radio Frequency Quadrupole (RFQ). This paper discusses high voltage breakdown mitigation strategies and presents the first results of the novel elliptical transport system. So far, 70 mA of beam has been transported through the new system with a normalized transverse RMS emittance of 0.2 π mm mrad.</description><identifier>ISSN: 0094-243X</identifier><identifier>EISSN: 1551-7616</identifier><identifier>DOI: 10.1063/1.4995782</identifier><identifier>CODEN: APCPCS</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Cesium ; Cesium vapor ; Collimation ; Emittance ; High voltages ; Ion extraction ; Perveance ; Phase matching ; Quadrupoles ; Spallation ; Transport</subject><ispartof>AIP conference proceedings, 2017, Vol.1869 (1)</ispartof><rights>Author(s)</rights><rights>2017 Author(s). Published by AIP Publishing.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,780,784,789,790,23930,23931,25140,27924,27925</link.rule.ids></links><search><contributor>Faircloth, Dan</contributor><creatorcontrib>Lawrie, S. R.</creatorcontrib><creatorcontrib>Faircloth, D. C.</creatorcontrib><creatorcontrib>Letchford, A. P.</creatorcontrib><creatorcontrib>Whitehead, M. O.</creatorcontrib><creatorcontrib>Wood, T.</creatorcontrib><title>Demonstrating H− beam focusing using an elliptical einzel lens</title><title>AIP conference proceedings</title><description>H− ion source research is being performed at the ISIS spallation neutron and muon facility on a dedicated Vessel for Extraction and Source Plasma Analyses (VESPA). The ion extraction and optics system presently being used on ISIS is centered on a combined-function sector dipole magnet. This traps cesium vapor escaping the ion source; mass-separates co-extracted electrons and stripped neutrals, and weak-focusses the highly asymmetric slit-shaped ion beam. Unfortunately the added drift length through the magnet under strong space-charge forces means up to 50% of the beam is collimated on the magnet. The VESPA has shown that the ISIS ion source actually produces 80 mA of beam current at standard settings, but because of magnet collimation only 55 mA is injected into the solenoid Low Energy Beam Transport (LEBT). A new purely electrostatic post-extraction system incorporating an einzel lens with an elliptical aperture is currently under test. This allows much greater flexibility of perveance and phase space matching for injection into the LEBT and Radio Frequency Quadrupole (RFQ). This paper discusses high voltage breakdown mitigation strategies and presents the first results of the novel elliptical transport system. So far, 70 mA of beam has been transported through the new system with a normalized transverse RMS emittance of 0.2 π mm mrad.</description><subject>Cesium</subject><subject>Cesium vapor</subject><subject>Collimation</subject><subject>Emittance</subject><subject>High voltages</subject><subject>Ion extraction</subject><subject>Perveance</subject><subject>Phase matching</subject><subject>Quadrupoles</subject><subject>Spallation</subject><subject>Transport</subject><issn>0094-243X</issn><issn>1551-7616</issn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2017</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNp9kMFKxDAQhoMoWFcPvkHBm9B1JmmT9qasqysseFHwFqbZVLq0aW1aQZ_As4_ok9ilC968zMDw_TPz_4ydI8wRpLjCeZxliUr5AQswSTBSEuUhCwCyOOKxeDlmJ95vAXimVBqw61tbN873HfWlew1XP1_fYW6pDovGDH43miq50FZV2faloSq0pfu0VVhZ50_ZUUGVt2f7PmPPd8unxSpaP94_LG7WUcvTtI84ZlgQZoUyCLmCXJIBYRIhOCkLSsb5-BFJ4JY4KE4Y8xyMMrRBbg2KGbuY9rZd8zZY3-ttM3RuPKk5ohwlo7uRupwob8p-tNQ43XZlTd2Hfm86jXqfjm43xX8wgt7F-ScQv1BBZrI</recordid><startdate>20170809</startdate><enddate>20170809</enddate><creator>Lawrie, S. R.</creator><creator>Faircloth, D. C.</creator><creator>Letchford, A. P.</creator><creator>Whitehead, M. O.</creator><creator>Wood, T.</creator><general>American Institute of Physics</general><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20170809</creationdate><title>Demonstrating H− beam focusing using an elliptical einzel lens</title><author>Lawrie, S. R. ; Faircloth, D. C. ; Letchford, A. P. ; Whitehead, M. O. ; Wood, T.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p288t-2191fa19f7c10b70b6ac03c5332a7e0764b297a602ea2072a142b0c7cad12ec13</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Cesium</topic><topic>Cesium vapor</topic><topic>Collimation</topic><topic>Emittance</topic><topic>High voltages</topic><topic>Ion extraction</topic><topic>Perveance</topic><topic>Phase matching</topic><topic>Quadrupoles</topic><topic>Spallation</topic><topic>Transport</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lawrie, S. R.</creatorcontrib><creatorcontrib>Faircloth, D. C.</creatorcontrib><creatorcontrib>Letchford, A. P.</creatorcontrib><creatorcontrib>Whitehead, M. O.</creatorcontrib><creatorcontrib>Wood, T.</creatorcontrib><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lawrie, S. R.</au><au>Faircloth, D. C.</au><au>Letchford, A. P.</au><au>Whitehead, M. O.</au><au>Wood, T.</au><au>Faircloth, Dan</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Demonstrating H− beam focusing using an elliptical einzel lens</atitle><btitle>AIP conference proceedings</btitle><date>2017-08-09</date><risdate>2017</risdate><volume>1869</volume><issue>1</issue><issn>0094-243X</issn><eissn>1551-7616</eissn><coden>APCPCS</coden><abstract>H− ion source research is being performed at the ISIS spallation neutron and muon facility on a dedicated Vessel for Extraction and Source Plasma Analyses (VESPA). The ion extraction and optics system presently being used on ISIS is centered on a combined-function sector dipole magnet. This traps cesium vapor escaping the ion source; mass-separates co-extracted electrons and stripped neutrals, and weak-focusses the highly asymmetric slit-shaped ion beam. Unfortunately the added drift length through the magnet under strong space-charge forces means up to 50% of the beam is collimated on the magnet. The VESPA has shown that the ISIS ion source actually produces 80 mA of beam current at standard settings, but because of magnet collimation only 55 mA is injected into the solenoid Low Energy Beam Transport (LEBT). A new purely electrostatic post-extraction system incorporating an einzel lens with an elliptical aperture is currently under test. This allows much greater flexibility of perveance and phase space matching for injection into the LEBT and Radio Frequency Quadrupole (RFQ). This paper discusses high voltage breakdown mitigation strategies and presents the first results of the novel elliptical transport system. So far, 70 mA of beam has been transported through the new system with a normalized transverse RMS emittance of 0.2 π mm mrad.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/1.4995782</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0094-243X |
ispartof | AIP conference proceedings, 2017, Vol.1869 (1) |
issn | 0094-243X 1551-7616 |
language | eng |
recordid | cdi_scitation_primary_10_1063_1_4995782 |
source | American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list) |
subjects | Cesium Cesium vapor Collimation Emittance High voltages Ion extraction Perveance Phase matching Quadrupoles Spallation Transport |
title | Demonstrating H− beam focusing using an elliptical einzel lens |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T21%3A01%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Demonstrating%20H%E2%88%92%20beam%20focusing%20using%20an%20elliptical%20einzel%20lens&rft.btitle=AIP%20conference%20proceedings&rft.au=Lawrie,%20S.%20R.&rft.date=2017-08-09&rft.volume=1869&rft.issue=1&rft.issn=0094-243X&rft.eissn=1551-7616&rft.coden=APCPCS&rft_id=info:doi/10.1063/1.4995782&rft_dat=%3Cproquest_scita%3E2116072243%3C/proquest_scita%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-p288t-2191fa19f7c10b70b6ac03c5332a7e0764b297a602ea2072a142b0c7cad12ec13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2116072243&rft_id=info:pmid/&rfr_iscdi=true |