Loading…

Note: Iodine dissociation with a pulsed arc discharge

A new method is presented to dissociate iodine molecules in gas discharge. A high repetition rate spark gap is designed and used to trigger the circuit. Absorption spectroscopy is applied to measure the dissociation fraction of iodine molecules. It is found that more than 35% of iodine molecules are...

Full description

Saved in:
Bibliographic Details
Published in:Review of scientific instruments 2017-08, Vol.88 (8), p.086111-086111
Main Authors: Saghafifar, H., Goodarzi, M. S.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A new method is presented to dissociate iodine molecules in gas discharge. A high repetition rate spark gap is designed and used to trigger the circuit. Absorption spectroscopy is applied to measure the dissociation fraction of iodine molecules. It is found that more than 35% of iodine molecules are dissociated. The effect of switching frequency on the dissociation coefficient is investigated by changing the frequency of the rotating spark gap. Pulsed and equivalent direct current circuits are compared, and it is found that in the constant current glow discharge the dissociation fraction is near to the zero and negligible.
ISSN:0034-6748
1089-7623
DOI:10.1063/1.4998262