Deployment of quasi-digital sensor for high temperature molten salt level measurement in pyroprocessing plants

Development of a liquid molten salt level sensor device that can detect the level of liquid molten salt in the process vessels of pyrochemical reprocessing of spent metallic fuels is detailed. It is proposed to apply a resistive-type pulsating sensor-based level measurement approach. There are no co...

Full description

Saved in:
Bibliographic Details
Published in:Review of scientific instruments 2018-04, Vol.89 (4), p.045007-045007
Main Authors: Sanga, Ramesh, Agarwal, Sourabh, Sivaramakrishna, M., Rao, G. Prabhakara
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c355t-be2c7dc4de29a1f2c0181ebcfdcf0ef155abcc4d1f62a35eb3cd190634291ddb3
cites cdi_FETCH-LOGICAL-c355t-be2c7dc4de29a1f2c0181ebcfdcf0ef155abcc4d1f62a35eb3cd190634291ddb3
container_end_page 045007
container_issue 4
container_start_page 045007
container_title Review of scientific instruments
container_volume 89
creator Sanga, Ramesh
Agarwal, Sourabh
Sivaramakrishna, M.
Rao, G. Prabhakara
description Development of a liquid molten salt level sensor device that can detect the level of liquid molten salt in the process vessels of pyrochemical reprocessing of spent metallic fuels is detailed. It is proposed to apply a resistive-type pulsating sensor-based level measurement approach. There are no commercially available sensors due to limitations of high temperature, radiation, and physical dimensions. A compact, simple, rugged, low power, and high precise pulsating sensor-based level probe and simple instrumentation for the molten salt liquid level sensor to work in the extreme conditions has been indigenously developed, with high precision and accuracy. The working principle, design concept, and results have been discussed. This level probe is mainly composed of the variable resistor made up of ceramic rods. This resistor constitutes the part of resistance-capacitance-type Logic Gate Oscillator (LGO). A change in the molten salt level inside the tank causes a small change in the resistance which in turn changes the pulse frequency of the LGO. Thus the frequency, the output of the instrument that is displayed on the LCD of an embedded system, is a function of molten salt level. In the present design, the range of level measurement is about 10 mm. The sensitivity in position measurement up to 10 mm is ∼2.5 kHz/mm.
doi_str_mv 10.1063/1.5012803
format article
fullrecord <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_scitation_primary_10_1063_1_5012803</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2033377176</sourcerecordid><originalsourceid>FETCH-LOGICAL-c355t-be2c7dc4de29a1f2c0181ebcfdcf0ef155abcc4d1f62a35eb3cd190634291ddb3</originalsourceid><addsrcrecordid>eNp9kE1v1DAQhi1E1S6lB_4A8hGQUjz25uuISkuRKvUC58ixx1sjJ049TqX99xh2gRMdaTSH99Gr0cPYGxCXIBr1ES5rAbIT6gXbgOj6qm2kesk2Qqht1bTb7oy9IvohytQAp-xM9i00CroNmz_jEuJ-wjnz6PjjqslX1u981oETzhQTd2Uf_O6BZ5wWTDqvCfkUQ8aZkw6ZB3zCwCfUVJLfVX7myz7FJUWDRH7e8SXoOdNrduJ0ILw43nP2_eb629VtdXf_5evVp7vKqLrO1YjStNZsLcpeg5NGQAc4GmeNE-igrvVoSgyukVrVOCpjoS8qtrIHa0d1zt4dessHjytSHiZPBkN5AuNKgxRKqbaFtino-wNqUiRK6IYl-Umn_QBi-KV3gOGot7Bvj7XrOKH9S_7xWYAPB4BMMZh9nJ9t-y_8FNM_cFisUz8B-jiUaA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2033377176</pqid></control><display><type>article</type><title>Deployment of quasi-digital sensor for high temperature molten salt level measurement in pyroprocessing plants</title><source>American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)</source><source>AIP Journals (American Institute of Physics)</source><creator>Sanga, Ramesh ; Agarwal, Sourabh ; Sivaramakrishna, M. ; Rao, G. Prabhakara</creator><creatorcontrib>Sanga, Ramesh ; Agarwal, Sourabh ; Sivaramakrishna, M. ; Rao, G. Prabhakara</creatorcontrib><description>Development of a liquid molten salt level sensor device that can detect the level of liquid molten salt in the process vessels of pyrochemical reprocessing of spent metallic fuels is detailed. It is proposed to apply a resistive-type pulsating sensor-based level measurement approach. There are no commercially available sensors due to limitations of high temperature, radiation, and physical dimensions. A compact, simple, rugged, low power, and high precise pulsating sensor-based level probe and simple instrumentation for the molten salt liquid level sensor to work in the extreme conditions has been indigenously developed, with high precision and accuracy. The working principle, design concept, and results have been discussed. This level probe is mainly composed of the variable resistor made up of ceramic rods. This resistor constitutes the part of resistance-capacitance-type Logic Gate Oscillator (LGO). A change in the molten salt level inside the tank causes a small change in the resistance which in turn changes the pulse frequency of the LGO. Thus the frequency, the output of the instrument that is displayed on the LCD of an embedded system, is a function of molten salt level. In the present design, the range of level measurement is about 10 mm. The sensitivity in position measurement up to 10 mm is ∼2.5 kHz/mm.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.5012803</identifier><identifier>PMID: 29716318</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States</publisher><ispartof>Review of scientific instruments, 2018-04, Vol.89 (4), p.045007-045007</ispartof><rights>Author(s)</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c355t-be2c7dc4de29a1f2c0181ebcfdcf0ef155abcc4d1f62a35eb3cd190634291ddb3</citedby><cites>FETCH-LOGICAL-c355t-be2c7dc4de29a1f2c0181ebcfdcf0ef155abcc4d1f62a35eb3cd190634291ddb3</cites><orcidid>0000-0003-4624-0686 ; 0000000346240686</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.5012803$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,780,782,784,795,27924,27925,76383</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29716318$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sanga, Ramesh</creatorcontrib><creatorcontrib>Agarwal, Sourabh</creatorcontrib><creatorcontrib>Sivaramakrishna, M.</creatorcontrib><creatorcontrib>Rao, G. Prabhakara</creatorcontrib><title>Deployment of quasi-digital sensor for high temperature molten salt level measurement in pyroprocessing plants</title><title>Review of scientific instruments</title><addtitle>Rev Sci Instrum</addtitle><description>Development of a liquid molten salt level sensor device that can detect the level of liquid molten salt in the process vessels of pyrochemical reprocessing of spent metallic fuels is detailed. It is proposed to apply a resistive-type pulsating sensor-based level measurement approach. There are no commercially available sensors due to limitations of high temperature, radiation, and physical dimensions. A compact, simple, rugged, low power, and high precise pulsating sensor-based level probe and simple instrumentation for the molten salt liquid level sensor to work in the extreme conditions has been indigenously developed, with high precision and accuracy. The working principle, design concept, and results have been discussed. This level probe is mainly composed of the variable resistor made up of ceramic rods. This resistor constitutes the part of resistance-capacitance-type Logic Gate Oscillator (LGO). A change in the molten salt level inside the tank causes a small change in the resistance which in turn changes the pulse frequency of the LGO. Thus the frequency, the output of the instrument that is displayed on the LCD of an embedded system, is a function of molten salt level. In the present design, the range of level measurement is about 10 mm. The sensitivity in position measurement up to 10 mm is ∼2.5 kHz/mm.</description><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp9kE1v1DAQhi1E1S6lB_4A8hGQUjz25uuISkuRKvUC58ixx1sjJ049TqX99xh2gRMdaTSH99Gr0cPYGxCXIBr1ES5rAbIT6gXbgOj6qm2kesk2Qqht1bTb7oy9IvohytQAp-xM9i00CroNmz_jEuJ-wjnz6PjjqslX1u981oETzhQTd2Uf_O6BZ5wWTDqvCfkUQ8aZkw6ZB3zCwCfUVJLfVX7myz7FJUWDRH7e8SXoOdNrduJ0ILw43nP2_eb629VtdXf_5evVp7vKqLrO1YjStNZsLcpeg5NGQAc4GmeNE-igrvVoSgyukVrVOCpjoS8qtrIHa0d1zt4dessHjytSHiZPBkN5AuNKgxRKqbaFtino-wNqUiRK6IYl-Umn_QBi-KV3gOGot7Bvj7XrOKH9S_7xWYAPB4BMMZh9nJ9t-y_8FNM_cFisUz8B-jiUaA</recordid><startdate>201804</startdate><enddate>201804</enddate><creator>Sanga, Ramesh</creator><creator>Agarwal, Sourabh</creator><creator>Sivaramakrishna, M.</creator><creator>Rao, G. Prabhakara</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-4624-0686</orcidid><orcidid>https://orcid.org/0000000346240686</orcidid></search><sort><creationdate>201804</creationdate><title>Deployment of quasi-digital sensor for high temperature molten salt level measurement in pyroprocessing plants</title><author>Sanga, Ramesh ; Agarwal, Sourabh ; Sivaramakrishna, M. ; Rao, G. Prabhakara</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c355t-be2c7dc4de29a1f2c0181ebcfdcf0ef155abcc4d1f62a35eb3cd190634291ddb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sanga, Ramesh</creatorcontrib><creatorcontrib>Agarwal, Sourabh</creatorcontrib><creatorcontrib>Sivaramakrishna, M.</creatorcontrib><creatorcontrib>Rao, G. Prabhakara</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sanga, Ramesh</au><au>Agarwal, Sourabh</au><au>Sivaramakrishna, M.</au><au>Rao, G. Prabhakara</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Deployment of quasi-digital sensor for high temperature molten salt level measurement in pyroprocessing plants</atitle><jtitle>Review of scientific instruments</jtitle><addtitle>Rev Sci Instrum</addtitle><date>2018-04</date><risdate>2018</risdate><volume>89</volume><issue>4</issue><spage>045007</spage><epage>045007</epage><pages>045007-045007</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>Development of a liquid molten salt level sensor device that can detect the level of liquid molten salt in the process vessels of pyrochemical reprocessing of spent metallic fuels is detailed. It is proposed to apply a resistive-type pulsating sensor-based level measurement approach. There are no commercially available sensors due to limitations of high temperature, radiation, and physical dimensions. A compact, simple, rugged, low power, and high precise pulsating sensor-based level probe and simple instrumentation for the molten salt liquid level sensor to work in the extreme conditions has been indigenously developed, with high precision and accuracy. The working principle, design concept, and results have been discussed. This level probe is mainly composed of the variable resistor made up of ceramic rods. This resistor constitutes the part of resistance-capacitance-type Logic Gate Oscillator (LGO). A change in the molten salt level inside the tank causes a small change in the resistance which in turn changes the pulse frequency of the LGO. Thus the frequency, the output of the instrument that is displayed on the LCD of an embedded system, is a function of molten salt level. In the present design, the range of level measurement is about 10 mm. The sensitivity in position measurement up to 10 mm is ∼2.5 kHz/mm.</abstract><cop>United States</cop><pmid>29716318</pmid><doi>10.1063/1.5012803</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0003-4624-0686</orcidid><orcidid>https://orcid.org/0000000346240686</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of scientific instruments, 2018-04, Vol.89 (4), p.045007-045007
issn 0034-6748
1089-7623
language eng
recordid cdi_scitation_primary_10_1063_1_5012803
source American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list); AIP Journals (American Institute of Physics)
title Deployment of quasi-digital sensor for high temperature molten salt level measurement in pyroprocessing plants
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T21%3A08%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Deployment%20of%20quasi-digital%20sensor%20for%20high%20temperature%20molten%20salt%20level%20measurement%20in%20pyroprocessing%20plants&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Sanga,%20Ramesh&rft.date=2018-04&rft.volume=89&rft.issue=4&rft.spage=045007&rft.epage=045007&rft.pages=045007-045007&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.5012803&rft_dat=%3Cproquest_scita%3E2033377176%3C/proquest_scita%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c355t-be2c7dc4de29a1f2c0181ebcfdcf0ef155abcc4d1f62a35eb3cd190634291ddb3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2033377176&rft_id=info:pmid/29716318&rfr_iscdi=true