Technique for measurement of energy loss of proton in target medium

Energy loss (EL) of charged particles in target medium needs special attention, when measurements are required to be done repeatedly over periods of couple of days. It is imperative to ensure that the measurements are not affected by the long term drifts of the accelerator beam energy and the associ...

Full description

Saved in:
Bibliographic Details
Main Author: Khadke, U. V.
Format: Conference Proceeding
Language:English
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Energy loss (EL) of charged particles in target medium needs special attention, when measurements are required to be done repeatedly over periods of couple of days. It is imperative to ensure that the measurements are not affected by the long term drifts of the accelerator beam energy and the associated electronic modules. For one such situation in measurement of EL of proton beam in thick target, we optimised and standardized the technique of measuring most probable energy loss of 24.774 MeV proton in aluminium target of thickness 330 mg/cm2. The paper described the method that we developed to ensure that our EL measurements were free from effects of drifts due to any associated electronic modules. The details of the energy spectrometer, basic principle and technique for energy loss measurements in target medium are described in this paper.
ISSN:0094-243X
1551-7616
DOI:10.1063/1.5032931