Loading…
Spectrophotometric determination of cefixime trihydrate via oxidative coupling reaction with amino phenazone
A simple, precise, rаpid, аccurate, sensitive and economical method was developed for the determination of Cefixime trihydrate (CFX). The oxidative coupling reaction with Amino Phenazone (APh) is used in this method, by using Sodium periodate as an oxidizing agent. The formed complex in aqueous solu...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | |
container_issue | 1 |
container_start_page | |
container_title | |
container_volume | 2394 |
creator | Al-Falluji, Mustafa Mohammed Abdulrahman, Maadh T. Khaleel, Ali Ibraheem |
description | A simple, precise, rаpid, аccurate, sensitive and economical method was developed for the determination of Cefixime trihydrate (CFX). The oxidative coupling reaction with Amino Phenazone (APh) is used in this method, by using Sodium periodate as an oxidizing agent. The formed complex in aqueous solution was measured at 524 nm. The effects of the analytical parameters are investigated. The validity of the method was conducted in accordance with the guidelines for the International Conference on Harmonization (ICH). Beer–Lambert law was obeyed in the 5–60 µg/ml range, with correlation coefficient (R2=0.9977). Molar absorptivity and Sandell index were found to be 3958.5 L.mol−1.cm−1 and 0.1282 µg cm−2 respectively. The average recovery of Cefixime trihydrate CFX was (100.323%). The detection limit was 0.01326 µg ml−1. The proposed method has proven to be efficient for the determination of Cefixime trihydrate CFX, in pharmaceutical formulations and pure form. |
doi_str_mv | 10.1063/5.0121113 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_scitation_primary_10_1063_5_0121113</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2733669738</sourcerecordid><originalsourceid>FETCH-LOGICAL-p168t-e18da6e78c76786ce1a91440456e497308cdbffe6ccebf3704aee71e0b82bad73</originalsourceid><addsrcrecordid>eNp9kM9LwzAUx4MoOKcH_4OAN6EzadokPcrwFww8qOAtpOmrzWibmGZz86-3bgNvnt7hfb6fx_sidEnJjBLObvIZoSmllB2hCc1zmghO-TGaEFJkSZqx91N0NgxLQtJCCDlB7YsHE4PzjYuugxiswRVECJ3tdbSux67GBmq7sR3gcd1sq6Aj4LXV2G1sNUJrwMatfGv7DxxAm13sy8YG69HisG-g19-uh3N0Uut2gIvDnKK3-7vX-WOyeH54mt8uEk-5jAlQWWkOQhrBheQGqC5olpEs55AVghFpqrKugRsDZc0EyTSAoEBKmZa6EmyKrvZeH9znCoaolm4V-vGkSgVjnI8SOVLXe2owNu5-VT7YToetWrugcnVoUvmq_g-mRP1W_xdgP1BkeQU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>2733669738</pqid></control><display><type>conference_proceeding</type><title>Spectrophotometric determination of cefixime trihydrate via oxidative coupling reaction with amino phenazone</title><source>American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)</source><creator>Al-Falluji, Mustafa Mohammed ; Abdulrahman, Maadh T. ; Khaleel, Ali Ibraheem</creator><contributor>Mohammed, Mohammed Ahmed</contributor><creatorcontrib>Al-Falluji, Mustafa Mohammed ; Abdulrahman, Maadh T. ; Khaleel, Ali Ibraheem ; Mohammed, Mohammed Ahmed</creatorcontrib><description>A simple, precise, rаpid, аccurate, sensitive and economical method was developed for the determination of Cefixime trihydrate (CFX). The oxidative coupling reaction with Amino Phenazone (APh) is used in this method, by using Sodium periodate as an oxidizing agent. The formed complex in aqueous solution was measured at 524 nm. The effects of the analytical parameters are investigated. The validity of the method was conducted in accordance with the guidelines for the International Conference on Harmonization (ICH). Beer–Lambert law was obeyed in the 5–60 µg/ml range, with correlation coefficient (R2=0.9977). Molar absorptivity and Sandell index were found to be 3958.5 L.mol−1.cm−1 and 0.1282 µg cm−2 respectively. The average recovery of Cefixime trihydrate CFX was (100.323%). The detection limit was 0.01326 µg ml−1. The proposed method has proven to be efficient for the determination of Cefixime trihydrate CFX, in pharmaceutical formulations and pure form.</description><identifier>ISSN: 0094-243X</identifier><identifier>EISSN: 1551-7616</identifier><identifier>DOI: 10.1063/5.0121113</identifier><identifier>CODEN: APCPCS</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Absorptivity ; Aqueous solutions ; Bouguer law ; Correlation coefficients ; Coupling ; Mathematical analysis ; Oxidation ; Oxidizing agents ; Spectrophotometry</subject><ispartof>AIP conference proceedings, 2022, Vol.2394 (1)</ispartof><rights>Author(s)</rights><rights>2022 Author(s). Published by AIP Publishing.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,780,784,789,790,23929,23930,25139,27923,27924</link.rule.ids></links><search><contributor>Mohammed, Mohammed Ahmed</contributor><creatorcontrib>Al-Falluji, Mustafa Mohammed</creatorcontrib><creatorcontrib>Abdulrahman, Maadh T.</creatorcontrib><creatorcontrib>Khaleel, Ali Ibraheem</creatorcontrib><title>Spectrophotometric determination of cefixime trihydrate via oxidative coupling reaction with amino phenazone</title><title>AIP conference proceedings</title><description>A simple, precise, rаpid, аccurate, sensitive and economical method was developed for the determination of Cefixime trihydrate (CFX). The oxidative coupling reaction with Amino Phenazone (APh) is used in this method, by using Sodium periodate as an oxidizing agent. The formed complex in aqueous solution was measured at 524 nm. The effects of the analytical parameters are investigated. The validity of the method was conducted in accordance with the guidelines for the International Conference on Harmonization (ICH). Beer–Lambert law was obeyed in the 5–60 µg/ml range, with correlation coefficient (R2=0.9977). Molar absorptivity and Sandell index were found to be 3958.5 L.mol−1.cm−1 and 0.1282 µg cm−2 respectively. The average recovery of Cefixime trihydrate CFX was (100.323%). The detection limit was 0.01326 µg ml−1. The proposed method has proven to be efficient for the determination of Cefixime trihydrate CFX, in pharmaceutical formulations and pure form.</description><subject>Absorptivity</subject><subject>Aqueous solutions</subject><subject>Bouguer law</subject><subject>Correlation coefficients</subject><subject>Coupling</subject><subject>Mathematical analysis</subject><subject>Oxidation</subject><subject>Oxidizing agents</subject><subject>Spectrophotometry</subject><issn>0094-243X</issn><issn>1551-7616</issn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2022</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNp9kM9LwzAUx4MoOKcH_4OAN6EzadokPcrwFww8qOAtpOmrzWibmGZz86-3bgNvnt7hfb6fx_sidEnJjBLObvIZoSmllB2hCc1zmghO-TGaEFJkSZqx91N0NgxLQtJCCDlB7YsHE4PzjYuugxiswRVECJ3tdbSux67GBmq7sR3gcd1sq6Aj4LXV2G1sNUJrwMatfGv7DxxAm13sy8YG69HisG-g19-uh3N0Uut2gIvDnKK3-7vX-WOyeH54mt8uEk-5jAlQWWkOQhrBheQGqC5olpEs55AVghFpqrKugRsDZc0EyTSAoEBKmZa6EmyKrvZeH9znCoaolm4V-vGkSgVjnI8SOVLXe2owNu5-VT7YToetWrugcnVoUvmq_g-mRP1W_xdgP1BkeQU</recordid><startdate>20221108</startdate><enddate>20221108</enddate><creator>Al-Falluji, Mustafa Mohammed</creator><creator>Abdulrahman, Maadh T.</creator><creator>Khaleel, Ali Ibraheem</creator><general>American Institute of Physics</general><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20221108</creationdate><title>Spectrophotometric determination of cefixime trihydrate via oxidative coupling reaction with amino phenazone</title><author>Al-Falluji, Mustafa Mohammed ; Abdulrahman, Maadh T. ; Khaleel, Ali Ibraheem</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p168t-e18da6e78c76786ce1a91440456e497308cdbffe6ccebf3704aee71e0b82bad73</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Absorptivity</topic><topic>Aqueous solutions</topic><topic>Bouguer law</topic><topic>Correlation coefficients</topic><topic>Coupling</topic><topic>Mathematical analysis</topic><topic>Oxidation</topic><topic>Oxidizing agents</topic><topic>Spectrophotometry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Al-Falluji, Mustafa Mohammed</creatorcontrib><creatorcontrib>Abdulrahman, Maadh T.</creatorcontrib><creatorcontrib>Khaleel, Ali Ibraheem</creatorcontrib><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Al-Falluji, Mustafa Mohammed</au><au>Abdulrahman, Maadh T.</au><au>Khaleel, Ali Ibraheem</au><au>Mohammed, Mohammed Ahmed</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Spectrophotometric determination of cefixime trihydrate via oxidative coupling reaction with amino phenazone</atitle><btitle>AIP conference proceedings</btitle><date>2022-11-08</date><risdate>2022</risdate><volume>2394</volume><issue>1</issue><issn>0094-243X</issn><eissn>1551-7616</eissn><coden>APCPCS</coden><abstract>A simple, precise, rаpid, аccurate, sensitive and economical method was developed for the determination of Cefixime trihydrate (CFX). The oxidative coupling reaction with Amino Phenazone (APh) is used in this method, by using Sodium periodate as an oxidizing agent. The formed complex in aqueous solution was measured at 524 nm. The effects of the analytical parameters are investigated. The validity of the method was conducted in accordance with the guidelines for the International Conference on Harmonization (ICH). Beer–Lambert law was obeyed in the 5–60 µg/ml range, with correlation coefficient (R2=0.9977). Molar absorptivity and Sandell index were found to be 3958.5 L.mol−1.cm−1 and 0.1282 µg cm−2 respectively. The average recovery of Cefixime trihydrate CFX was (100.323%). The detection limit was 0.01326 µg ml−1. The proposed method has proven to be efficient for the determination of Cefixime trihydrate CFX, in pharmaceutical formulations and pure form.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/5.0121113</doi><tpages>10</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0094-243X |
ispartof | AIP conference proceedings, 2022, Vol.2394 (1) |
issn | 0094-243X 1551-7616 |
language | eng |
recordid | cdi_scitation_primary_10_1063_5_0121113 |
source | American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list) |
subjects | Absorptivity Aqueous solutions Bouguer law Correlation coefficients Coupling Mathematical analysis Oxidation Oxidizing agents Spectrophotometry |
title | Spectrophotometric determination of cefixime trihydrate via oxidative coupling reaction with amino phenazone |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T21%3A57%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Spectrophotometric%20determination%20of%20cefixime%20trihydrate%20via%20oxidative%20coupling%20reaction%20with%20amino%20phenazone&rft.btitle=AIP%20conference%20proceedings&rft.au=Al-Falluji,%20Mustafa%20Mohammed&rft.date=2022-11-08&rft.volume=2394&rft.issue=1&rft.issn=0094-243X&rft.eissn=1551-7616&rft.coden=APCPCS&rft_id=info:doi/10.1063/5.0121113&rft_dat=%3Cproquest_scita%3E2733669738%3C/proquest_scita%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-p168t-e18da6e78c76786ce1a91440456e497308cdbffe6ccebf3704aee71e0b82bad73%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2733669738&rft_id=info:pmid/&rfr_iscdi=true |