Loading…
Type T-130/130-12.8 cogeneration steam turbines with reheating
The design features and basic thermal scheme of the cogeneration turbines for a rated power capacity of 130 MW and steam parameters of 12.8 MPa and 540/540°C are considered. Figures characterizing the calculated economic effect from the use of steam reheating are presented.
Saved in:
Published in: | Thermal engineering 2008, Vol.55 (8), p.637-641 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The design features and basic thermal scheme of the cogeneration turbines for a rated power capacity of 130 MW and steam parameters of 12.8 MPa and 540/540°C are considered. Figures characterizing the calculated economic effect from the use of steam reheating are presented. |
---|---|
ISSN: | 0040-6015 1555-6301 |
DOI: | 10.1134/S0040601508080028 |