Loading…
Multi-jet Impingement Cooling of a Hot Flat Steel Plate
One of the most important steps to control the quality in steel hot rolling is the Runout Table (ROT) Cooling. In this investigation, the heat transfer of water jets impinging on a hot flat steel plate was studied under temperatures below the boiling point to understand the convection heat transfer...
Saved in:
Published in: | Energy procedia 2014, Vol.61, p.1835-1839 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | One of the most important steps to control the quality in steel hot rolling is the Runout Table (ROT) Cooling. In this investigation, the heat transfer of water jets impinging on a hot flat steel plate was studied under temperatures below the boiling point to understand the convection heat transfer phenomena which is a major step preceding the boiling. Single axisymmetric jet and a pair of interacting jets are simulated using Computational Fluid Dynamics (CFD). The RANS model under steady and transient conditions as well as the k-É› turbulence model are used for both 2D axisymmetric and 3D simulations. The water flow rate influence on the jets cooling characteristics is investigated.
Two sets of boundary conditions, constant temperature and constant heat flux were applied at the surface of the steel plate and evaluated. The single jet numerical results are successfully compared to published data based on measurements and analytical models. The two jets thermal performance was found to be unaffected because the jets are too far from each other to generate any additional thermal interaction. |
---|---|
ISSN: | 1876-6102 1876-6102 |
DOI: | 10.1016/j.egypro.2014.12.224 |