Loading…
Chromatographic alignment by warping and dynamic programming as a pre-processing tool for PARAFAC modelling of liquid chromatography–mass spectrometry data
Solutes analysed with LC–MS are characterised by their retention times and mass spectra, and quantified by the intensities measured. This highly selective information can be extracted by multiway modelling. However, for full use and interpretability it is necessary that the assumptions made for the...
Saved in:
Published in: | Journal of Chromatography A 2002-07, Vol.961 (2), p.237-244 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c428t-27bc55afeffc297d8633f246a1c7462f2e951d9f146830a89be9656ece47bac03 |
---|---|
cites | cdi_FETCH-LOGICAL-c428t-27bc55afeffc297d8633f246a1c7462f2e951d9f146830a89be9656ece47bac03 |
container_end_page | 244 |
container_issue | 2 |
container_start_page | 237 |
container_title | Journal of Chromatography A |
container_volume | 961 |
creator | Bylund, Dan Danielsson, Rolf Malmquist, Gunnar Markides, Karin E. |
description | Solutes analysed with LC–MS are characterised by their retention times and mass spectra, and quantified by the intensities measured. This highly selective information can be extracted by multiway modelling. However, for full use and interpretability it is necessary that the assumptions made for the model are valid. For PARAFAC modelling, the assumption is a trilinear data structure. With LC–MS, several factors, e.g. non-linear detector response and ionisation suppression may introduce deviations from trilinearity. The single largest problem, however, is the retention time shifts not related to the true sample variations. In this paper, a time warping algorithm for alignment of LC–MS data in the chromatographic direction has been examined. Several refinements have been implemented and the features are demonstrated for both simulated and real data. With moderate time shifts present in the data, pre-processing with this algorithm yields approximately trilinear data for which reasonable models can be made. |
doi_str_mv | 10.1016/S0021-9673(02)00588-5 |
format | article |
fullrecord | <record><control><sourceid>proquest_swepu</sourceid><recordid>TN_cdi_swepub_primary_oai_DiVA_org_miun_2512</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0021967302005885</els_id><sourcerecordid>71998995</sourcerecordid><originalsourceid>FETCH-LOGICAL-c428t-27bc55afeffc297d8633f246a1c7462f2e951d9f146830a89be9656ece47bac03</originalsourceid><addsrcrecordid>eNqFkctu1TAQhrMA0VJ4BJA3IJAI2M59VUUHCkiVQNy21sQenxrFcWonVNnxDl335XgSnHOOWnasRvrnm-ufJE8Yfc0oK998pZSztCmr7AXlLykt6jot7iXHt_JR8jCEn5Syilb8QXLEOKvzkrPj5GZz4Z2FyW09jBdGEujNdrA4TKRbyBX40QxbAoMiahnARmD0K2vtTg8EooBpFCWGsGqTcz3RzpPP7Zf2rN0Q6xT2_ZpymvTmcjaKyH-nLn9-X1sIgYQR5RQTOPmFKJjgUXJfQx_w8SGeJN_P3n3bfEjPP73_uGnPU5nzekp51cmiAI1aS95Uqi6zTPO8BCareKbm2BRMNZrlZZ1RqJsOm7IoUWJedSBpdpK82vcNVzjOnRi9seAX4cCIt-ZHK5zfCmvmQfCC8Yg_3-Px7MsZwxRzQcYjYUA3B1GxpqmbpohgsQeldyF41LedGRWrdWJnnVg9EpSLnXVirXt6GDB3FtVd1cG3CDw7ABAk9NrDIE2447KqZlm5bnq65zB-75dBL4I0OEhUxsdfC-XMf1b5C2CVvOY</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>71998995</pqid></control><display><type>article</type><title>Chromatographic alignment by warping and dynamic programming as a pre-processing tool for PARAFAC modelling of liquid chromatography–mass spectrometry data</title><source>ScienceDirect Freedom Collection 2022-2024</source><creator>Bylund, Dan ; Danielsson, Rolf ; Malmquist, Gunnar ; Markides, Karin E.</creator><creatorcontrib>Bylund, Dan ; Danielsson, Rolf ; Malmquist, Gunnar ; Markides, Karin E.</creatorcontrib><description>Solutes analysed with LC–MS are characterised by their retention times and mass spectra, and quantified by the intensities measured. This highly selective information can be extracted by multiway modelling. However, for full use and interpretability it is necessary that the assumptions made for the model are valid. For PARAFAC modelling, the assumption is a trilinear data structure. With LC–MS, several factors, e.g. non-linear detector response and ionisation suppression may introduce deviations from trilinearity. The single largest problem, however, is the retention time shifts not related to the true sample variations. In this paper, a time warping algorithm for alignment of LC–MS data in the chromatographic direction has been examined. Several refinements have been implemented and the features are demonstrated for both simulated and real data. With moderate time shifts present in the data, pre-processing with this algorithm yields approximately trilinear data for which reasonable models can be made.</description><identifier>ISSN: 0021-9673</identifier><identifier>DOI: 10.1016/S0021-9673(02)00588-5</identifier><identifier>PMID: 12184621</identifier><identifier>CODEN: JOCRAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical chemistry ; Chemistry ; Chromatographic methods and physical methods associated with chromatography ; Chromatography, Liquid - methods ; Exact sciences and technology ; Factor Analysis, Statistical ; Kemi ; Mass Spectrometry - methods ; MATEMATIK ; MATHEMATICS ; Models, Theoretical ; NATURAL SCIENCES ; NATURVETENSKAP ; Other chromatographic methods ; parallel factor analysis ; time warping algorithm</subject><ispartof>Journal of Chromatography A, 2002-07, Vol.961 (2), p.237-244</ispartof><rights>2002 Elsevier Science B.V.</rights><rights>2002 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c428t-27bc55afeffc297d8633f246a1c7462f2e951d9f146830a89be9656ece47bac03</citedby><cites>FETCH-LOGICAL-c428t-27bc55afeffc297d8633f246a1c7462f2e951d9f146830a89be9656ece47bac03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=13781362$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12184621$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://urn.kb.se/resolve?urn=urn:nbn:se:miun:diva-2512$$DView record from Swedish Publication Index$$Hfree_for_read</backlink></links><search><creatorcontrib>Bylund, Dan</creatorcontrib><creatorcontrib>Danielsson, Rolf</creatorcontrib><creatorcontrib>Malmquist, Gunnar</creatorcontrib><creatorcontrib>Markides, Karin E.</creatorcontrib><title>Chromatographic alignment by warping and dynamic programming as a pre-processing tool for PARAFAC modelling of liquid chromatography–mass spectrometry data</title><title>Journal of Chromatography A</title><addtitle>J Chromatogr A</addtitle><description>Solutes analysed with LC–MS are characterised by their retention times and mass spectra, and quantified by the intensities measured. This highly selective information can be extracted by multiway modelling. However, for full use and interpretability it is necessary that the assumptions made for the model are valid. For PARAFAC modelling, the assumption is a trilinear data structure. With LC–MS, several factors, e.g. non-linear detector response and ionisation suppression may introduce deviations from trilinearity. The single largest problem, however, is the retention time shifts not related to the true sample variations. In this paper, a time warping algorithm for alignment of LC–MS data in the chromatographic direction has been examined. Several refinements have been implemented and the features are demonstrated for both simulated and real data. With moderate time shifts present in the data, pre-processing with this algorithm yields approximately trilinear data for which reasonable models can be made.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Chromatographic methods and physical methods associated with chromatography</subject><subject>Chromatography, Liquid - methods</subject><subject>Exact sciences and technology</subject><subject>Factor Analysis, Statistical</subject><subject>Kemi</subject><subject>Mass Spectrometry - methods</subject><subject>MATEMATIK</subject><subject>MATHEMATICS</subject><subject>Models, Theoretical</subject><subject>NATURAL SCIENCES</subject><subject>NATURVETENSKAP</subject><subject>Other chromatographic methods</subject><subject>parallel factor analysis</subject><subject>time warping algorithm</subject><issn>0021-9673</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNqFkctu1TAQhrMA0VJ4BJA3IJAI2M59VUUHCkiVQNy21sQenxrFcWonVNnxDl335XgSnHOOWnasRvrnm-ufJE8Yfc0oK998pZSztCmr7AXlLykt6jot7iXHt_JR8jCEn5Syilb8QXLEOKvzkrPj5GZz4Z2FyW09jBdGEujNdrA4TKRbyBX40QxbAoMiahnARmD0K2vtTg8EooBpFCWGsGqTcz3RzpPP7Zf2rN0Q6xT2_ZpymvTmcjaKyH-nLn9-X1sIgYQR5RQTOPmFKJjgUXJfQx_w8SGeJN_P3n3bfEjPP73_uGnPU5nzekp51cmiAI1aS95Uqi6zTPO8BCareKbm2BRMNZrlZZ1RqJsOm7IoUWJedSBpdpK82vcNVzjOnRi9seAX4cCIt-ZHK5zfCmvmQfCC8Yg_3-Px7MsZwxRzQcYjYUA3B1GxpqmbpohgsQeldyF41LedGRWrdWJnnVg9EpSLnXVirXt6GDB3FtVd1cG3CDw7ABAk9NrDIE2447KqZlm5bnq65zB-75dBL4I0OEhUxsdfC-XMf1b5C2CVvOY</recordid><startdate>20020705</startdate><enddate>20020705</enddate><creator>Bylund, Dan</creator><creator>Danielsson, Rolf</creator><creator>Malmquist, Gunnar</creator><creator>Markides, Karin E.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>ADTPV</scope><scope>AOWAS</scope><scope>DG5</scope></search><sort><creationdate>20020705</creationdate><title>Chromatographic alignment by warping and dynamic programming as a pre-processing tool for PARAFAC modelling of liquid chromatography–mass spectrometry data</title><author>Bylund, Dan ; Danielsson, Rolf ; Malmquist, Gunnar ; Markides, Karin E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c428t-27bc55afeffc297d8633f246a1c7462f2e951d9f146830a89be9656ece47bac03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Chromatographic methods and physical methods associated with chromatography</topic><topic>Chromatography, Liquid - methods</topic><topic>Exact sciences and technology</topic><topic>Factor Analysis, Statistical</topic><topic>Kemi</topic><topic>Mass Spectrometry - methods</topic><topic>MATEMATIK</topic><topic>MATHEMATICS</topic><topic>Models, Theoretical</topic><topic>NATURAL SCIENCES</topic><topic>NATURVETENSKAP</topic><topic>Other chromatographic methods</topic><topic>parallel factor analysis</topic><topic>time warping algorithm</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bylund, Dan</creatorcontrib><creatorcontrib>Danielsson, Rolf</creatorcontrib><creatorcontrib>Malmquist, Gunnar</creatorcontrib><creatorcontrib>Markides, Karin E.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>SwePub</collection><collection>SwePub Articles</collection><collection>SWEPUB Mittuniversitetet</collection><jtitle>Journal of Chromatography A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bylund, Dan</au><au>Danielsson, Rolf</au><au>Malmquist, Gunnar</au><au>Markides, Karin E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Chromatographic alignment by warping and dynamic programming as a pre-processing tool for PARAFAC modelling of liquid chromatography–mass spectrometry data</atitle><jtitle>Journal of Chromatography A</jtitle><addtitle>J Chromatogr A</addtitle><date>2002-07-05</date><risdate>2002</risdate><volume>961</volume><issue>2</issue><spage>237</spage><epage>244</epage><pages>237-244</pages><issn>0021-9673</issn><coden>JOCRAM</coden><abstract>Solutes analysed with LC–MS are characterised by their retention times and mass spectra, and quantified by the intensities measured. This highly selective information can be extracted by multiway modelling. However, for full use and interpretability it is necessary that the assumptions made for the model are valid. For PARAFAC modelling, the assumption is a trilinear data structure. With LC–MS, several factors, e.g. non-linear detector response and ionisation suppression may introduce deviations from trilinearity. The single largest problem, however, is the retention time shifts not related to the true sample variations. In this paper, a time warping algorithm for alignment of LC–MS data in the chromatographic direction has been examined. Several refinements have been implemented and the features are demonstrated for both simulated and real data. With moderate time shifts present in the data, pre-processing with this algorithm yields approximately trilinear data for which reasonable models can be made.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>12184621</pmid><doi>10.1016/S0021-9673(02)00588-5</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0021-9673 |
ispartof | Journal of Chromatography A, 2002-07, Vol.961 (2), p.237-244 |
issn | 0021-9673 |
language | eng |
recordid | cdi_swepub_primary_oai_DiVA_org_miun_2512 |
source | ScienceDirect Freedom Collection 2022-2024 |
subjects | Analytical chemistry Chemistry Chromatographic methods and physical methods associated with chromatography Chromatography, Liquid - methods Exact sciences and technology Factor Analysis, Statistical Kemi Mass Spectrometry - methods MATEMATIK MATHEMATICS Models, Theoretical NATURAL SCIENCES NATURVETENSKAP Other chromatographic methods parallel factor analysis time warping algorithm |
title | Chromatographic alignment by warping and dynamic programming as a pre-processing tool for PARAFAC modelling of liquid chromatography–mass spectrometry data |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T22%3A25%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_swepu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Chromatographic%20alignment%20by%20warping%20and%20dynamic%20programming%20as%20a%20pre-processing%20tool%20for%20PARAFAC%20modelling%20of%20liquid%20chromatography%E2%80%93mass%20spectrometry%20data&rft.jtitle=Journal%20of%20Chromatography%20A&rft.au=Bylund,%20Dan&rft.date=2002-07-05&rft.volume=961&rft.issue=2&rft.spage=237&rft.epage=244&rft.pages=237-244&rft.issn=0021-9673&rft.coden=JOCRAM&rft_id=info:doi/10.1016/S0021-9673(02)00588-5&rft_dat=%3Cproquest_swepu%3E71998995%3C/proquest_swepu%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c428t-27bc55afeffc297d8633f246a1c7462f2e951d9f146830a89be9656ece47bac03%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=71998995&rft_id=info:pmid/12184621&rfr_iscdi=true |