Loading…
Prognostic value of comprehensive intracoronary physiology assessment early after heart transplantation
Abstract Aims We evaluated the long-term prognostic value of invasively assessing coronary physiology after heart transplantation in a large multicentre registry. Methods and results Comprehensive intracoronary physiology assessment measuring fractional flow reserve (FFR), the index of microcirculat...
Saved in:
Published in: | European heart journal 2021-12, Vol.42 (48), p.4918-4929 |
---|---|
Main Authors: | , , , , , , , , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Abstract
Aims
We evaluated the long-term prognostic value of invasively assessing coronary physiology after heart transplantation in a large multicentre registry.
Methods and results
Comprehensive intracoronary physiology assessment measuring fractional flow reserve (FFR), the index of microcirculatory resistance (IMR), and coronary flow reserve (CFR) was performed in 254 patients at baseline (a median of 7.2 weeks) and in 240 patients at 1 year after transplantation (199 patients had both baseline and 1-year measurement). Patients were classified into those with normal physiology, reduced FFR (FFR ≤ 0.80), and microvascular dysfunction (either IMR ≥ 25 or CFR ≤ 2.0 with FFR > 0.80). The primary outcome was the composite of death or re-transplantation at 10 years. At baseline, 5.5% had reduced FFR; 36.6% had microvascular dysfunction. Baseline reduced FFR [adjusted hazard ratio (aHR) 2.33, 95% confidence interval (CI) 0.88–6.15; P = 0.088] and microvascular dysfunction (aHR 0.88, 95% CI 0.44–1.79; P = 0.73) were not predictors of death and re-transplantation at 10 years. At 1 year, 5.0% had reduced FFR; 23.8% had microvascular dysfunction. One-year reduced FFR (aHR 2.98, 95% CI 1.13–7.87; P = 0.028) and microvascular dysfunction (aHR 2.33, 95% CI 1.19–4.59; P = 0.015) were associated with significantly increased risk of death or re-transplantation at 10 years. Invasive measures of coronary physiology improved the prognostic performance of clinical variables (χ2 improvement: 7.41, P = 0.006). However, intravascular ultrasound-derived changes in maximal intimal thickness were not predictive of outcomes.
Conclusion
Abnormal coronary physiology 1 year after heart transplantation was common and was a significant predictor of death or re-transplantation at 10 years.
Graphical Abstract
Abnormal coronary physiology at 1 year after heart transplantation. CRF, coronary flow reserve; FFR, fractional flow reserve; IMR, index of microcirculatory resistance. |
---|---|
ISSN: | 0195-668X 1522-9645 1522-9645 |
DOI: | 10.1093/eurheartj/ehab568 |