Loading…

Impact of percutaneous femoral arteriotomy closure using the MANTA TM device on vascular and bleeding complications after transcatheter aortic valve replacement

To evaluate the feasibility of fully percutaneous closure using a novel collagen-based vascular closure device after transfemoral aortic valve replacement (TAVR). TAVR is utilized increasingly for the treatment of severe symptomatic aortic stenosis. Vascular complications related to access and closu...

Full description

Saved in:
Bibliographic Details
Published in:Catheterization and cardiovascular interventions 2018-11, Vol.92 (5), p.954-961
Main Authors: De Palma, Rodney, Settergren, Magnus, Rück, Andreas, Linder, Rikard, Saleh, Nawzad
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To evaluate the feasibility of fully percutaneous closure using a novel collagen-based vascular closure device after transfemoral aortic valve replacement (TAVR). TAVR is utilized increasingly for the treatment of severe symptomatic aortic stenosis. Vascular complications related to access and closure dominate the adverse event profile of the procedure despite progressively reducing arteriotomy caliber. The advent of a novel collagen-based device (MANTA ) and preliminary data suggest this could be used as a routine percutaneous closure device. A prospective observational study of unselected consecutive patients undergoing TAVR in a single center. Data were collected via hospital electronic records and the SWEDEHEART registry. The primary clinical outcome was closure success and time to hemostasis. Secondary outcomes included VARC-2 defined major and minor vascular and bleeding complications within 30 days using suture-based closure with Prostar-XL within the same center. A consecutive cohort of 346 patients underwent TAVR via the transfemoral approach. Vascular closure with MANTA was successful in all with a mean time to hemostasis of 42 sec (SD 115.5, range 0-600). The composite of all-cause mortality and major complications related to the main access site was similar between the groups (1.1% vs 1.9%, P = .61). Major bleeding occurred less frequently with MANTA (1.1% vs 7.8%, P = .02). The novel use of a collagen-based vascular closure device for large caliber arteriotomy is feasible in an unselected population undergoing transfemoral TAVR and appears efficacious compared to percutaneous suture-based closure. These data should prompt larger studies to evaluate efficacy and safety.
ISSN:1522-1946
1522-726X
DOI:10.1002/ccd.27595