A MODEL FOR LIQUID SLUG LENGTH DISTRIBUTION IN VERTICAL GAS-LIQUID SLUG FLOW

The slug length and the trailing Taylor bubble velocity in an upward vertical slug flow were measured by using the optical probes and the EKTAPRO 1000 high speed motion analyzer. The correlation between the trailing bubble velocity and the length of liquid slug ahead of that bubble is derived from t...

Full description

Saved in:
Bibliographic Details
Published in:Journal of hydrodynamics. Series B 2009-08, Vol.21 (4), p.491-498
Main Authors: XIA, Guo-dong, CUI, Zhen-zhen, LIU, Qing, ZHOU, Fang-de, HU, Ming-sheng
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The slug length and the trailing Taylor bubble velocity in an upward vertical slug flow were measured by using the optical probes and the EKTAPRO 1000 high speed motion analyzer. The correlation between the trailing bubble velocity and the length of liquid slug ahead of that bubble is derived from the experimental data. Based on this correlation as well as the bubble overtaking mechanism, a model for the slug length distribution at any designated locations along the pipe is proposed. The predicted results are in agreement with the experimental data.
ISSN:1001-6058
1878-0342
DOI:10.1016/S1001-6058(08)60175-4