Loading…
Pressure drop across a fixed bed reactor with mechanical failure of catalyst pellets described by simplified ergun's equation
The pressure drop across a laboratory-scale catalyst packed bed with mechanical failure of catalyst pellets has been examined. It was found that the increased pressure drop can be described by a simplified model deduced from Ergun's equation. The pressure drop is determined mainly by the term o...
Saved in:
Published in: | China particuology 2005-04, Vol.3 (1), p.23-25 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The pressure drop across a laboratory-scale catalyst packed bed with mechanical failure of catalyst pellets has been examined. It was found that the increased pressure drop can be described by a simplified model deduced from Ergun's equation. The pressure drop is determined mainly by the term of viscous energy loss. |
---|---|
ISSN: | 1672-2515 |
DOI: | 10.1016/S1672-2515(07)60157-2 |