Loading…

Pressure drop across a fixed bed reactor with mechanical failure of catalyst pellets described by simplified ergun's equation

The pressure drop across a laboratory-scale catalyst packed bed with mechanical failure of catalyst pellets has been examined. It was found that the increased pressure drop can be described by a simplified model deduced from Ergun's equation. The pressure drop is determined mainly by the term o...

Full description

Saved in:
Bibliographic Details
Published in:China particuology 2005-04, Vol.3 (1), p.23-25
Main Authors: Zhang, Dong, Fan, Panfeng, Wu, Dongfang, Li, Yongdan
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The pressure drop across a laboratory-scale catalyst packed bed with mechanical failure of catalyst pellets has been examined. It was found that the increased pressure drop can be described by a simplified model deduced from Ergun's equation. The pressure drop is determined mainly by the term of viscous energy loss.
ISSN:1672-2515