Loading…

Comparison of the veracity of real-time perfusion, harmonic angio, and ultraharmonic myocardial contrast imaging modes in evaluation of acute myocardial infarction area

Background Innovative advancements in ultrasound instrumentation present a number of imaging modalities for myocardial contrast echocardiography (MCE) in ischemic syndromes. How well they compare to each other in diagnostic accuracy in the detection of acute myocardial infarction is unclear. The pur...

Full description

Saved in:
Bibliographic Details
Published in:Chinese medical journal 2006-02, Vol.119 (3), p.179-184
Main Authors: XING, Yan-qiu, ZHANG, Yun, LI, Da-qing, LIU, Xiang-qun, LI, Xiu-qin, ZHAO, Chang-qin, CHEN, Mei, GAO, Hai-qing
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background Innovative advancements in ultrasound instrumentation present a number of imaging modalities for myocardial contrast echocardiography (MCE) in ischemic syndromes. How well they compare to each other in diagnostic accuracy in the detection of acute myocardial infarction is unclear. The purpose of this study was to assess the relative accuracy of 3 different imaging modes of MCE, low mechanical index (MI) real-time perfusion imaging (RTPI), triggered harmonic angio mode (HA), and ultraharmonic imaging mode (UH) in the detection of acute experimental myocardial infarction within the time frame suitable for potential reperfusion. Methods MCE was performed in 10 open-chest dogs using RTPI, triggered HA and triggered UH modes at baseline and one hour after occlusion of left anterior descending coronary artery. Presence or absence of peffusion defects, and the perfusion defect size when present, were analyzed and compared with the infarct size delineated by triphenyltetrazolium chloride (TTC) staining. Results The infarct area was (15.8-2.4)% by TTC staining; Peffusion defect area by MCE was similar to anatomic infarct area in all the three MCE approaches: (16.1-2.7)% by RTPI mode, (15.5-2.9)% by HA mode, and (15.5-3.0)% by UH mode. The sensitivity, specificity and overall diagnostic accuracy in the detection of myocardial infarction were 100%, 88%, and 94% for RTPI mode, 88%, 100%, and 94 % for HA mode, and 100%, 75%, and 88% for UH mode. Conclusion All modes of MCE, RTPI, triggered HA mode and triggered UH mode have excellent diagnostic accuracy in the immediate hour of acute coronary occlusion within the optimal time frame suitable for reperfusion therapy.
ISSN:0366-6999
2542-5641