Loading…
Comparison of adenosine stress and dobutamine stress by real-time myocardial contrast echocardiography in detecting myocardium ischemia in dogs
Background Real-time perfusion imaging (RTPI) using ultrasound contrast agents has shown good "accuracy" in detecting myocardial infarction, however its accuracy in the assessment of peri-infarct ischemia and stress echocardiography are not known. The aim of this study was to determine the accuracy...
Saved in:
Published in: | Chinese medical journal 2009-09, Vol.122 (17), p.2002-2007 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 2007 |
container_issue | 17 |
container_start_page | 2002 |
container_title | Chinese medical journal |
container_volume | 122 |
creator | Xing, Yan-qiu Hou, Bo-wen Zhang, Yun Liu, Xiang-qun Gao, Hai-qing |
description | Background Real-time perfusion imaging (RTPI) using ultrasound contrast agents has shown good "accuracy" in detecting myocardial infarction, however its accuracy in the assessment of peri-infarct ischemia and stress echocardiography are not known. The aim of this study was to determine the accuracy of RTPI in assessment of peri-infarct ischemia during dobutamine and adenosine stress. Methods We employed the RTPI modality (Agilent and ATL Philips) in a canine model (18 dogs) of distal coronary occlusion and proximal coronary stenosis. Using coronary flow probe recordings, the physiologic significance of proximal coronary stenosis was established by confirming abolition of the coronary reserve. The contrast agent Optison was given as a slow bolus injection at baseline, during prolonged distal coronary occlusion, during adenosine bolus stress and during dobutamine stress. Triphenyltetrazolium chloride (TTC) staining was used to verity a distal infarction. RTPI recordings at baseline, the distal coronary occlusion and stress protocols were randomly mixed and reviewed blindly. Results In all but one dog, RTPI detected a distal infarct as small as 9% of the left ventricle. The sensitivity, specificity and overall diagnostic accuracy of RTPI in the detection of distal infarcts were: 94%, 89% and 92%, respectively. The sensitivity, specificity, and overall diagnostic accuracy of RTPI in the assessment of peri-infarction ischemia were 83%, 92% and 88% for adenosine stress and 95%, 86% and 91% for dobutamine stress, respectively. Conclusions Even small distal infarcts can be detected by RTPI; peri-infarct ischemia can be accurately recognized by RTPt during stress; adenosine and dobutamine stress appear equally reliable in the RTPI evaluation of peri-infarct ischemia. |
doi_str_mv | 10.3760/cma.j.issn.0366-6999.2009.17.008 |
format | article |
fullrecord | <record><control><sourceid>wanfang_jour_proqu</sourceid><recordid>TN_cdi_wanfang_journals_zhcmj200917008</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cqvip_id>31517693</cqvip_id><wanfj_id>zhcmj200917008</wanfj_id><sourcerecordid>zhcmj200917008</sourcerecordid><originalsourceid>FETCH-LOGICAL-c268t-68754b242293c95a4766977471c59f865ced3a1d1642ad9a645b2e29d4764acf3</originalsourceid><addsrcrecordid>eNpNkMtu1DAUhr0A0VJ4BWSxADZJfYnteIlG3KRKbMo6OrGdjIfYntqJ0PASfeUaplSsjvTr-885-hD6QEnLlSTXJkB7aH0psSVcykZqrVtGiG6pagnpn6HLp_wCvSzlQAgTQskX6IJq1VPei0t0v0vhCNmXFHGaMFgXU_HR4bJmVwqGaLFN47ZC-C8dTzg7WJrVB4fDKRnI1sOCTYprhrJiZ_bnMM0ZjvsT9hFbtzqz-jg_NbaAfTF7Fzz8BdJcXqHnEyzFvX6cV-jH50-3u6_Nzfcv33YfbxrDZL82sleiG1nHmOZGC-iUlFqpTlEj9NRLYZzlQC2VHQOrQXZiZI5pW8EOzMSv0Lvz3l8QJ4jzcEhbjvXi8HtvwuGPR6qqxQq-P4PHnO42V9Yh1J_dskB0aSuD4h2RTGlSyTeP5DYGZ4dj9gHyafgnuwJvz0CVE-e7amIYwfyc_OIGTgVVUnP-ABlMkc8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>734062790</pqid></control><display><type>article</type><title>Comparison of adenosine stress and dobutamine stress by real-time myocardial contrast echocardiography in detecting myocardium ischemia in dogs</title><source>HEAL-Link subscriptions: Lippincott Williams & Wilkins</source><creator>Xing, Yan-qiu ; Hou, Bo-wen ; Zhang, Yun ; Liu, Xiang-qun ; Gao, Hai-qing</creator><creatorcontrib>Xing, Yan-qiu ; Hou, Bo-wen ; Zhang, Yun ; Liu, Xiang-qun ; Gao, Hai-qing</creatorcontrib><description>Background Real-time perfusion imaging (RTPI) using ultrasound contrast agents has shown good "accuracy" in detecting myocardial infarction, however its accuracy in the assessment of peri-infarct ischemia and stress echocardiography are not known. The aim of this study was to determine the accuracy of RTPI in assessment of peri-infarct ischemia during dobutamine and adenosine stress. Methods We employed the RTPI modality (Agilent and ATL Philips) in a canine model (18 dogs) of distal coronary occlusion and proximal coronary stenosis. Using coronary flow probe recordings, the physiologic significance of proximal coronary stenosis was established by confirming abolition of the coronary reserve. The contrast agent Optison was given as a slow bolus injection at baseline, during prolonged distal coronary occlusion, during adenosine bolus stress and during dobutamine stress. Triphenyltetrazolium chloride (TTC) staining was used to verity a distal infarction. RTPI recordings at baseline, the distal coronary occlusion and stress protocols were randomly mixed and reviewed blindly. Results In all but one dog, RTPI detected a distal infarct as small as 9% of the left ventricle. The sensitivity, specificity and overall diagnostic accuracy of RTPI in the detection of distal infarcts were: 94%, 89% and 92%, respectively. The sensitivity, specificity, and overall diagnostic accuracy of RTPI in the assessment of peri-infarction ischemia were 83%, 92% and 88% for adenosine stress and 95%, 86% and 91% for dobutamine stress, respectively. Conclusions Even small distal infarcts can be detected by RTPI; peri-infarct ischemia can be accurately recognized by RTPt during stress; adenosine and dobutamine stress appear equally reliable in the RTPI evaluation of peri-infarct ischemia.</description><identifier>ISSN: 0366-6999</identifier><identifier>DOI: 10.3760/cma.j.issn.0366-6999.2009.17.008</identifier><identifier>PMID: 19781385</identifier><language>eng</language><publisher>China: Department of Geriatrics, Qihi Hospital, Shandong University, Jinan, Shandong 250012, China%Institute of Basic Medicine, Shandong Academy of Medical Science, Jinan, Shandong 250062, China%Department of Cardiology, Qihi Hospital, Shandong University, Jinan, Shandong 250012, China</publisher><subject>Adenosine - toxicity ; Animals ; Coronary Circulation - drug effects ; Dobutamine - toxicity ; Dogs ; Echocardiography - methods ; Female ; Hemodynamics - drug effects ; Male ; Myocardial Infarction - diagnostic imaging ; 多巴酚丁胺 ; 实时 ; 应力检测 ; 心肌缺血 ; 腺苷 ; 负荷 ; 超声心动图 ; 造影</subject><ispartof>Chinese medical journal, 2009-09, Vol.122 (17), p.2002-2007</ispartof><rights>Copyright © Wanfang Data Co. Ltd. All Rights Reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://image.cqvip.com/vip1000/qk/85656X/85656X.jpg</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19781385$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Xing, Yan-qiu</creatorcontrib><creatorcontrib>Hou, Bo-wen</creatorcontrib><creatorcontrib>Zhang, Yun</creatorcontrib><creatorcontrib>Liu, Xiang-qun</creatorcontrib><creatorcontrib>Gao, Hai-qing</creatorcontrib><title>Comparison of adenosine stress and dobutamine stress by real-time myocardial contrast echocardiography in detecting myocardium ischemia in dogs</title><title>Chinese medical journal</title><addtitle>Chinese Medical Journal</addtitle><description>Background Real-time perfusion imaging (RTPI) using ultrasound contrast agents has shown good "accuracy" in detecting myocardial infarction, however its accuracy in the assessment of peri-infarct ischemia and stress echocardiography are not known. The aim of this study was to determine the accuracy of RTPI in assessment of peri-infarct ischemia during dobutamine and adenosine stress. Methods We employed the RTPI modality (Agilent and ATL Philips) in a canine model (18 dogs) of distal coronary occlusion and proximal coronary stenosis. Using coronary flow probe recordings, the physiologic significance of proximal coronary stenosis was established by confirming abolition of the coronary reserve. The contrast agent Optison was given as a slow bolus injection at baseline, during prolonged distal coronary occlusion, during adenosine bolus stress and during dobutamine stress. Triphenyltetrazolium chloride (TTC) staining was used to verity a distal infarction. RTPI recordings at baseline, the distal coronary occlusion and stress protocols were randomly mixed and reviewed blindly. Results In all but one dog, RTPI detected a distal infarct as small as 9% of the left ventricle. The sensitivity, specificity and overall diagnostic accuracy of RTPI in the detection of distal infarcts were: 94%, 89% and 92%, respectively. The sensitivity, specificity, and overall diagnostic accuracy of RTPI in the assessment of peri-infarction ischemia were 83%, 92% and 88% for adenosine stress and 95%, 86% and 91% for dobutamine stress, respectively. Conclusions Even small distal infarcts can be detected by RTPI; peri-infarct ischemia can be accurately recognized by RTPt during stress; adenosine and dobutamine stress appear equally reliable in the RTPI evaluation of peri-infarct ischemia.</description><subject>Adenosine - toxicity</subject><subject>Animals</subject><subject>Coronary Circulation - drug effects</subject><subject>Dobutamine - toxicity</subject><subject>Dogs</subject><subject>Echocardiography - methods</subject><subject>Female</subject><subject>Hemodynamics - drug effects</subject><subject>Male</subject><subject>Myocardial Infarction - diagnostic imaging</subject><subject>多巴酚丁胺</subject><subject>实时</subject><subject>应力检测</subject><subject>心肌缺血</subject><subject>腺苷</subject><subject>负荷</subject><subject>超声心动图</subject><subject>造影</subject><issn>0366-6999</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNpNkMtu1DAUhr0A0VJ4BWSxADZJfYnteIlG3KRKbMo6OrGdjIfYntqJ0PASfeUaplSsjvTr-885-hD6QEnLlSTXJkB7aH0psSVcykZqrVtGiG6pagnpn6HLp_wCvSzlQAgTQskX6IJq1VPei0t0v0vhCNmXFHGaMFgXU_HR4bJmVwqGaLFN47ZC-C8dTzg7WJrVB4fDKRnI1sOCTYprhrJiZ_bnMM0ZjvsT9hFbtzqz-jg_NbaAfTF7Fzz8BdJcXqHnEyzFvX6cV-jH50-3u6_Nzfcv33YfbxrDZL82sleiG1nHmOZGC-iUlFqpTlEj9NRLYZzlQC2VHQOrQXZiZI5pW8EOzMSv0Lvz3l8QJ4jzcEhbjvXi8HtvwuGPR6qqxQq-P4PHnO42V9Yh1J_dskB0aSuD4h2RTGlSyTeP5DYGZ4dj9gHyafgnuwJvz0CVE-e7amIYwfyc_OIGTgVVUnP-ABlMkc8</recordid><startdate>20090905</startdate><enddate>20090905</enddate><creator>Xing, Yan-qiu</creator><creator>Hou, Bo-wen</creator><creator>Zhang, Yun</creator><creator>Liu, Xiang-qun</creator><creator>Gao, Hai-qing</creator><general>Department of Geriatrics, Qihi Hospital, Shandong University, Jinan, Shandong 250012, China%Institute of Basic Medicine, Shandong Academy of Medical Science, Jinan, Shandong 250062, China%Department of Cardiology, Qihi Hospital, Shandong University, Jinan, Shandong 250012, China</general><scope>2RA</scope><scope>92L</scope><scope>CQIGP</scope><scope>W94</scope><scope>WU4</scope><scope>~WA</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope><scope>2B.</scope><scope>4A8</scope><scope>92I</scope><scope>93N</scope><scope>PSX</scope><scope>TCJ</scope></search><sort><creationdate>20090905</creationdate><title>Comparison of adenosine stress and dobutamine stress by real-time myocardial contrast echocardiography in detecting myocardium ischemia in dogs</title><author>Xing, Yan-qiu ; Hou, Bo-wen ; Zhang, Yun ; Liu, Xiang-qun ; Gao, Hai-qing</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c268t-68754b242293c95a4766977471c59f865ced3a1d1642ad9a645b2e29d4764acf3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Adenosine - toxicity</topic><topic>Animals</topic><topic>Coronary Circulation - drug effects</topic><topic>Dobutamine - toxicity</topic><topic>Dogs</topic><topic>Echocardiography - methods</topic><topic>Female</topic><topic>Hemodynamics - drug effects</topic><topic>Male</topic><topic>Myocardial Infarction - diagnostic imaging</topic><topic>多巴酚丁胺</topic><topic>实时</topic><topic>应力检测</topic><topic>心肌缺血</topic><topic>腺苷</topic><topic>负荷</topic><topic>超声心动图</topic><topic>造影</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Xing, Yan-qiu</creatorcontrib><creatorcontrib>Hou, Bo-wen</creatorcontrib><creatorcontrib>Zhang, Yun</creatorcontrib><creatorcontrib>Liu, Xiang-qun</creatorcontrib><creatorcontrib>Gao, Hai-qing</creatorcontrib><collection>维普_期刊</collection><collection>中文科技期刊数据库-CALIS站点</collection><collection>中文科技期刊数据库-7.0平台</collection><collection>中文科技期刊数据库-自然科学</collection><collection>中文科技期刊数据库-自然科学-生物科学</collection><collection>中文科技期刊数据库- 镜像站点</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><collection>Wanfang Data Journals - Hong Kong</collection><collection>WANFANG Data Centre</collection><collection>Wanfang Data Journals</collection><collection>万方数据期刊 - 香港版</collection><collection>China Online Journals (COJ)</collection><collection>China Online Journals (COJ)</collection><jtitle>Chinese medical journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Xing, Yan-qiu</au><au>Hou, Bo-wen</au><au>Zhang, Yun</au><au>Liu, Xiang-qun</au><au>Gao, Hai-qing</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of adenosine stress and dobutamine stress by real-time myocardial contrast echocardiography in detecting myocardium ischemia in dogs</atitle><jtitle>Chinese medical journal</jtitle><addtitle>Chinese Medical Journal</addtitle><date>2009-09-05</date><risdate>2009</risdate><volume>122</volume><issue>17</issue><spage>2002</spage><epage>2007</epage><pages>2002-2007</pages><issn>0366-6999</issn><abstract>Background Real-time perfusion imaging (RTPI) using ultrasound contrast agents has shown good "accuracy" in detecting myocardial infarction, however its accuracy in the assessment of peri-infarct ischemia and stress echocardiography are not known. The aim of this study was to determine the accuracy of RTPI in assessment of peri-infarct ischemia during dobutamine and adenosine stress. Methods We employed the RTPI modality (Agilent and ATL Philips) in a canine model (18 dogs) of distal coronary occlusion and proximal coronary stenosis. Using coronary flow probe recordings, the physiologic significance of proximal coronary stenosis was established by confirming abolition of the coronary reserve. The contrast agent Optison was given as a slow bolus injection at baseline, during prolonged distal coronary occlusion, during adenosine bolus stress and during dobutamine stress. Triphenyltetrazolium chloride (TTC) staining was used to verity a distal infarction. RTPI recordings at baseline, the distal coronary occlusion and stress protocols were randomly mixed and reviewed blindly. Results In all but one dog, RTPI detected a distal infarct as small as 9% of the left ventricle. The sensitivity, specificity and overall diagnostic accuracy of RTPI in the detection of distal infarcts were: 94%, 89% and 92%, respectively. The sensitivity, specificity, and overall diagnostic accuracy of RTPI in the assessment of peri-infarction ischemia were 83%, 92% and 88% for adenosine stress and 95%, 86% and 91% for dobutamine stress, respectively. Conclusions Even small distal infarcts can be detected by RTPI; peri-infarct ischemia can be accurately recognized by RTPt during stress; adenosine and dobutamine stress appear equally reliable in the RTPI evaluation of peri-infarct ischemia.</abstract><cop>China</cop><pub>Department of Geriatrics, Qihi Hospital, Shandong University, Jinan, Shandong 250012, China%Institute of Basic Medicine, Shandong Academy of Medical Science, Jinan, Shandong 250062, China%Department of Cardiology, Qihi Hospital, Shandong University, Jinan, Shandong 250012, China</pub><pmid>19781385</pmid><doi>10.3760/cma.j.issn.0366-6999.2009.17.008</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0366-6999 |
ispartof | Chinese medical journal, 2009-09, Vol.122 (17), p.2002-2007 |
issn | 0366-6999 |
language | eng |
recordid | cdi_wanfang_journals_zhcmj200917008 |
source | HEAL-Link subscriptions: Lippincott Williams & Wilkins |
subjects | Adenosine - toxicity Animals Coronary Circulation - drug effects Dobutamine - toxicity Dogs Echocardiography - methods Female Hemodynamics - drug effects Male Myocardial Infarction - diagnostic imaging 多巴酚丁胺 实时 应力检测 心肌缺血 腺苷 负荷 超声心动图 造影 |
title | Comparison of adenosine stress and dobutamine stress by real-time myocardial contrast echocardiography in detecting myocardium ischemia in dogs |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T21%3A42%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wanfang_jour_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20adenosine%20stress%20and%20dobutamine%20stress%20by%20real-time%20myocardial%20contrast%20echocardiography%20in%20detecting%20myocardium%20ischemia%20in%20dogs&rft.jtitle=Chinese%20medical%20journal&rft.au=Xing,%20Yan-qiu&rft.date=2009-09-05&rft.volume=122&rft.issue=17&rft.spage=2002&rft.epage=2007&rft.pages=2002-2007&rft.issn=0366-6999&rft_id=info:doi/10.3760/cma.j.issn.0366-6999.2009.17.008&rft_dat=%3Cwanfang_jour_proqu%3Ezhcmj200917008%3C/wanfang_jour_proqu%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c268t-68754b242293c95a4766977471c59f865ced3a1d1642ad9a645b2e29d4764acf3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=734062790&rft_id=info:pmid/19781385&rft_cqvip_id=31517693&rft_wanfj_id=zhcmj200917008&rfr_iscdi=true |