Loading…

Flow measurement method based on a fringing field capacitor structure

A flow measurement method based on fringing field capacitors is proposed. Alternate annular electrodes are fabricated on the surface of the tube to constitute the capacitor structure, and the fringing field penetrates the wall to achieve the detection of fluid. The electric field between two electro...

Full description

Saved in:
Bibliographic Details
Published in:Electronics letters 2016-10, Vol.52 (21), p.1771-1772
Main Authors: Liu, Zhe, Wang, WenLian
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A flow measurement method based on fringing field capacitors is proposed. Alternate annular electrodes are fabricated on the surface of the tube to constitute the capacitor structure, and the fringing field penetrates the wall to achieve the detection of fluid. The electric field between two electrodes distributes along the annular wall, which is conducive to analyse the relationship of the capacitance and the flow. The proposed measurement method is suitable for the industrial applications due to the simple structure and low cost. A water flow measurement experiment was implemented by making foil capacitor on the surface of a plastic tube.
ISSN:0013-5194
1350-911X
1350-911X
DOI:10.1049/el.2016.2081