A parametric analysis on the vulnerability of internally insulated solid masonry walls to rot damage

This paper investigates the risk of rot damage in brick solid masonry walls (SMWs) before and after they have received an Internal Wall Insulation (IWI) system. One-dimensional simulations in Delphin were calibrated against laboratory experiments of full-scale insulated and uninsulated SMW assemblie...

Full description

Saved in:
Bibliographic Details
Main Authors: Eirini Mantesi, David Allinson, Roelandus Tersteeg
Format: Default Conference proceeding
Published: 2021
Subjects:
Online Access:https://hdl.handle.net/2134/14611548.v1
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1818166695599013888
author Eirini Mantesi
David Allinson
Roelandus Tersteeg
author_facet Eirini Mantesi
David Allinson
Roelandus Tersteeg
author_sort Eirini Mantesi (5472893)
collection Figshare
description This paper investigates the risk of rot damage in brick solid masonry walls (SMWs) before and after they have received an Internal Wall Insulation (IWI) system. One-dimensional simulations in Delphin were calibrated against laboratory experiments of full-scale insulated and uninsulated SMW assemblies in the Hygrothermal Test Facility. A parametric analysis was conducted to assess the sensitivity of the walls to a list of scenario uncertainties. The results indicated that in all Test Cases (TCs) the risk of rot damage increased when internal insulation is retrofitted to a SMW.
format Default
Conference proceeding
id rr-article-14611548
institution Loughborough University
publishDate 2021
record_format Figshare
spelling rr-article-146115482021-05-13T00:00:00Z A parametric analysis on the vulnerability of internally insulated solid masonry walls to rot damage Eirini Mantesi (5472893) David Allinson (1248501) Roelandus Tersteeg (2824805) Solid Masonry Walls Internal Wall Insulation Retrofit Rot Damage Parametric Analysis This paper investigates the risk of rot damage in brick solid masonry walls (SMWs) before and after they have received an Internal Wall Insulation (IWI) system. One-dimensional simulations in Delphin were calibrated against laboratory experiments of full-scale insulated and uninsulated SMW assemblies in the Hygrothermal Test Facility. A parametric analysis was conducted to assess the sensitivity of the walls to a list of scenario uncertainties. The results indicated that in all Test Cases (TCs) the risk of rot damage increased when internal insulation is retrofitted to a SMW. 2021-05-13T00:00:00Z Text Conference contribution 2134/14611548.v1 https://figshare.com/articles/conference_contribution/A_parametric_analysis_on_the_vulnerability_of_internally_insulated_solid_masonry_walls_to_rot_damage/14611548 CC BY 4.0
spellingShingle Solid Masonry Walls
Internal Wall Insulation
Retrofit
Rot Damage
Parametric Analysis
Eirini Mantesi
David Allinson
Roelandus Tersteeg
A parametric analysis on the vulnerability of internally insulated solid masonry walls to rot damage
title A parametric analysis on the vulnerability of internally insulated solid masonry walls to rot damage
title_full A parametric analysis on the vulnerability of internally insulated solid masonry walls to rot damage
title_fullStr A parametric analysis on the vulnerability of internally insulated solid masonry walls to rot damage
title_full_unstemmed A parametric analysis on the vulnerability of internally insulated solid masonry walls to rot damage
title_short A parametric analysis on the vulnerability of internally insulated solid masonry walls to rot damage
title_sort parametric analysis on the vulnerability of internally insulated solid masonry walls to rot damage
topic Solid Masonry Walls
Internal Wall Insulation
Retrofit
Rot Damage
Parametric Analysis
url https://hdl.handle.net/2134/14611548.v1