Loading…

Cardiac power parameters during hypovolemia, induced by the lower body negative pressure technique, in healthy volunteers

Background: Changes in cardiac power parameters incorporate changes in both aortic flow and blood pressure. We hypothesized that dynamic and non-dynamic cardiac power parameters would track hypovolemia better than equivalent flow- and pressure parameters, both during spontaneous breathing and non-in...

Full description

Saved in:
Bibliographic Details
Main Authors: Rimehaug, Audun Eskeland, Hoff, Ingrid E Taraldsrud, Høiseth, Lars Øivind, Hisdal, Jonny, Aadahl, Petter, Kirkeby-Garstad, Idar
Format: Article
Language:English
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background: Changes in cardiac power parameters incorporate changes in both aortic flow and blood pressure. We hypothesized that dynamic and non-dynamic cardiac power parameters would track hypovolemia better than equivalent flow- and pressure parameters, both during spontaneous breathing and non-invasive positive pressure ventilation (NPPV). Methods: Fourteen healthy volunteers underwent lower body negative pressure (LBNP) of 0, −20, −40, −60 and −80 mmHg to simulate hypovolemia, both during spontaneous breathing and during NPPV. We recorded aortic flow using suprasternal ultrasound Doppler and blood pressure using Finometer, and calculated dynamic and non-dynamic parameters of cardiac power, flow and blood pressure. These were assessed on their association with LBNP-levels. Results: Respiratory variation in peak aortic flow was the dynamic parameter most affected during spontaneous breathing increasing 103 % (p < 0.001) from baseline to LBNP −80 mmHg. Respiratory variation in pulse pressure was the most affected dynamic parameter during NPPV, increasing 119 % (p < 0.001) from baseline to LBNP −80 mmHg. The cardiac power integral was the most affected non-dynamic parameter falling 59 % (p < 0.001) from baseline to LBNP −80 mmHg during spontaneous breathing, and 68 % (p < 0.001) during NPPV. Conclusions: Dynamic cardiac power parameters were not better than dynamic flow- and pressure parameters at tracking hypovolemia, seemingly due to previously unknown variation in peripheral vascular resistance matching respiratory changes in hemodynamics. Of non-dynamic parameters, the power parameters track hypovolemia slightly better than equivalent flow parameters, and far better than equivalent pressure parameters.