Loading…
Open-circuit potential of a Pt electrode immersed in different aqueous solutions
The aim of this study is to investigate the multi-day behavior of the electromotive force (EMF) between Pt and reference Ag/AgCl, KCl sat. electrodes immersed in various aqueous systems (deionized water, 1 × 10 −3 M H 2 SO 4 solution and 0.15 M KCl solution) at 32 °C and also at ambient temperature,...
Saved in:
Published in: | Reaction kinetics, mechanisms and catalysis mechanisms and catalysis, 2018-02, Vol.123 (1), p.165-175 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The aim of this study is to investigate the multi-day behavior of the electromotive force (EMF) between Pt and reference Ag/AgCl, KCl
sat.
electrodes immersed in various aqueous systems (deionized water, 1 × 10
−3
M H
2
SO
4
solution and 0.15 M KCl solution) at 32 °C and also at ambient temperature, without oxygen removal and redox species introduction. The control test of EMF behavior in the presence of redox species was performed with cyanide complexes of Fe
2+
and Fe
3+
ions at ambient temperature. In experiments with deionized water, systems were protected against the influence of daylight and static electricity. The results have shown diurnal oscillations of EMF in all investigated systems with amplitudes in the range ≈ 1 to 25 mV depending on applied experimental conditions. EMF oscillations in deionized water were independent on the applied temperature and yielded amplitudes of 15–25 mV in daylight regime, and only a few mV when protected from its influence. The effect of electrostatic electricity was not observed. Diurnal EMF oscillations with the amplitudes ≤ 5 mV were observed individually in 0.15 M KCl solution, redox system and after 4 days of investigation in H
2
SO
4
solution. Results presented in this work pointed out that the behavior of Pt–oxygen electrode is specific and very complex, even in the simplest system such as deionized water. To investigate the origin of the observed EMF oscillations and the application of Pt–oxygen electrode in in situ multi-day dynamics studies under open-circuit potential condition, additional theoretical and experimental methods and particularly electrochemical ones, must be applied. |
---|---|
ISSN: | 1878-5190 1878-5204 |
DOI: | 10.1007/s11144-017-1330-8 |