Enhancement of nucleate boiling heat transfer using structured surfaces

•Nucleate pool boiling heat transfer of structured surfaces are studied.•Two different pool liquids such as water and isopropyl alcohol are used as test fluid.•Tests are carried for heat flux input in the range of 0–300kW/m2 for water.•Structured surface Exhibits 250% higher enhancement in heat tran...

Full description

Saved in:
Bibliographic Details
Published in:Chemical engineering and processing 2017-12, Vol.122, p.222-234
Main Authors: Nirgude, Vishal V., Sahu, Santosh K.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:•Nucleate pool boiling heat transfer of structured surfaces are studied.•Two different pool liquids such as water and isopropyl alcohol are used as test fluid.•Tests are carried for heat flux input in the range of 0–300kW/m2 for water.•Structured surface Exhibits 250% higher enhancement in heat transfer coefficient. In the present study, an experimental investigation has been carried out to investigate the nucleate boiling heat transfer performance of various orthogonally intersecting tunnel structured surfaces. Tests were carried at atmospheric pressure and saturated pool boiling conditions by using water and isopropyl alcohol as pool liquid. The orthogonally intersecting tunnel geometries with varying tunnel depth of 0.5mm, 1mm and width of 0.61mm, 0.725mm were developed on copper test sections by using wire-electric discharge machining (Wire-EDM) process. The experimental tests were carried by varying heat flux input in the range of 0–300kW/m2 for water and 0–250kW/m2 for isopropyl alcohol. The experimental results indicated that the variation in tunnel dimensions significantly affects the heat transfer performance of the surfaces. The comparison of heat transfer coefficients (HTC) indicated that the orthogonally intersecting tunnel structures augmented the boiling heat transfer performance. For water, the heat transfer coefficient was enhanced up to 250% with considerable reduction in wall superheat. Present experimental study reveals that the tunnel structure enhances the liquid transport network to active nucleation sites on the surface delaying dry out and improves liquid vapor interaction on surface.
ISSN:0255-2701
1873-3204
DOI:10.1016/j.cep.2017.10.013