Loading…

[OA165] Optimization of quantitative 99MTC-MAA SPECT/CT imaging for 90Y RADIOEMBOLIZATION: A 3D-printed phantom study

Radioembolization (RE) with 90Y-microspheres has gained widespread acceptance as a safe and effective technique for treating liver malignancies. Accurate quantification in RE is a key step in treatment planning optimization and it is becoming a pressing issue in the light of the Directive 2013/59/EU...

Full description

Saved in:
Bibliographic Details
Published in:Physica medica 2018-08, Vol.52, p.63-63
Main Authors: Ungania, Sara, Nocentini, Sandro, Iaccarino, Giuseppe, D’Andrea, Marco, D’Arienzo, Marco, Cacciatore, Alessandra, Sciuto, Rosa, Vallati, Giulio, Pizzi, Giuseppe, Strigari, Lidia, Guerrisi, Maria G.
Format: Article
Language:English
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Radioembolization (RE) with 90Y-microspheres has gained widespread acceptance as a safe and effective technique for treating liver malignancies. Accurate quantification in RE is a key step in treatment planning optimization and it is becoming a pressing issue in the light of the Directive 2013/59/EURATOM, stating that individual dose planning must be enforced in legislation by EU member states by February 2018. The aim of this study was to develop a SPECT/CT imaging protocol for quantitative imaging optimization in RE based on a novel anthropomorphic 3D-printed phantom. A SPECT/CT system provided with a novel software for imaging quantification was used to assess the quantitative accuracy of 99mTc-MAA SPECT imaging for treatment planning in RE. Gamma camera calibration factors and recovery coefficients were determined performing preliminary SPECT/CT acquisitions of a homogeneous and a NEMA/IEC phantom, respectively. The quantification procedure was then validated using a 3D-printed anthropomorphic phantom provided with a fillable liver section and multiple inserts. Raw data reconstruction was performed using two independent software: i) the built-in xSPECT package, using both the Ordered Subset Expectation–Maximization (OSEM) and the Ordered Subset Conjugated Gradient (OSCG) algorithm; ii) the commercially available QSPECT software based on OSEM method. All reconstructed images were manually fused and appropriate regions of interest (ROIs) were drawn on the MIM 6.1.7 system. The measured activity concentration is consistent within 3% with the expected activity concentration values. This is in keeping with the overall accuracy (
ISSN:1120-1797
1724-191X