Experimental investigation on start-up of mechanically pumped cooling loop

The start-up of a two phase cooling system is a complex transient phenomenon especially for the mechanically pumped two phase cooling loop (MPCL) which is now a promising thermal control method for efficiently extracting heat from large electronic equipments. In this paper the system design and work...

Full description

Saved in:
Bibliographic Details
Published in:Energy conversion and management 2008-10, Vol.49 (10), p.2595-2601
Main Authors: Jie, Liu, Mou, Lv, shuang-xi, Zhang, Kai-hua, Guo, Zhen-hui, He, Ting-xuen, Li
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The start-up of a two phase cooling system is a complex transient phenomenon especially for the mechanically pumped two phase cooling loop (MPCL) which is now a promising thermal control method for efficiently extracting heat from large electronic equipments. In this paper the system design and work principle as well as the test setup of a MPCL is presented and the start-up processes of the MPCL are studied. Experiments on the start-up processes under a variety of conditions were conducted. Special attention has been paid to the startups of the system in different evaporative temperature variable mass flow or heating load and some abnormal start-up pre-history. The transient flow exchange between the main loop and the accumulator was observed and discussed according to the different start-up patterns, which have been identified as pre-condition pump start-up and heat load start-up. During the start-up processes the system presents good stability and each part of the system performs a reasonable temperature wave except of some superheat phenomena in the evaporator. The superheat is mainly related to the evaporative temperature and the initial liquid distribution in the evaporator. In general the lower is the evaporative temperature the higher is the superheat that occurs. It also indicates that the degree of superheat is not too high when the evaporator is flooded with liquid and will not cause damage to the source equipments. In conclusion the well start-up processes in different situations may cause some liquid superheats and evaporator temperature overshoots but they will not affect much the steady state operation of the MPCL.
ISSN:0196-8904
1879-2227
DOI:10.1016/j.enconman.2008.05.007